One of the most important forces generated during gait is the vertical ground reaction force (vGRF). This force can be measured using force plates, but these can limit the scope of gait analysis. This paper presents a method to estimate the vGRF using inertial measurement units (IMU) and machine learning techniques. Four wearable IMUs were used to obtain flexion/extension angles of the hip, knee, and ankle joints, and an IMU placed over the C7 vertebra to measure vertical acceleration. We trained and compared the performance of two machine learning algorithms: feedforward neural networks (FNN) and random forest (RF). We investigated the importance of the inputs introduced into the models and analyzed in detail the contribution of lower limb kinematics and vertical acceleration to model performance. The results suggest that the inclusion of vertical acceleration increases the root mean square error in the FNN, while the RF appears to decrease it. We also analyzed the ability of the models to construct the force signal, with particular emphasis on the magnitude and timing of the vGRF peaks. Using the proposed method, we concluded that FNN and RF models can estimate the vGRF with high accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, the strong correlation between vertical acceleration peaks and ground reaction force (GRF) reflects the energy output efficiency of lower limb muscles 67 , which can be used to quantify motor ability and assist rehabilitation training (Fig. 3a) 68 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [67]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946 · cited 1×
“We have used the Recti fi ed Linear Unit (ReLu) as the activation function of the neurons, the Adam algorithm (Kingma and Ba, 2014) as the optimizer to adjust the network weights, and the RMSE as the loss function.”
MethodScikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016 · cited 1×
“The RF models have been trained with SciKit Learn Python Library (Pedregosa et al., 2011).”
Method(2014) · Cited by 33,419
Permutation importance: a corrected feature importance measure
Altmann, A., Toloşi, L., Sander, O., & Lengauer, T. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq134 · Cited by 2,843 · cited 1×
“To understand the influence of the angles, the angular velocities, the vertical acceleration, and the cycle gait in the training of the FNN and RFmodels, we have calculated the feature importance by feature permutation (Altmann et al., 2010).”
MethodIntroduction to multi-layer feed-forward neural networks
Svozil, D., Kvasnicka, V., & Pospichal, J. (1997) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(97)00061-0 · Cited by 1,600 · cited 2×
“The FNN models are a kind of arti fi cial neural networks based on neurons that receive an input signal and process them by the activation function to an output signal (Svozil et al., 1997; Sharma et al., 2017).”
BackgroundLearning to learn by gradient descent by gradient descent
Andrychowicz, M., Denil, M., Gomez, S., Hoffman, M. W., Pfau, D., Schaul, T., Shillingford, B., & de Freitas, N. (2016) · arXiv · doi:10.48550/arxiv.1606.04474 · Cited by 1,486 · cited 1×
“The adjustment of the weights of the neural network is usually performed by back-propagation, employing a non-linear optimization method such as the gradient descent algorithm (Andrychowicz et al., 2016).”
MethodACTIVATION FUNCTIONS IN NEURAL NETWORKS
Sharma, S., Sharma, S., & Athaiya, A. (2020) · International Journal of Engineering Applied Sciences and Technology · doi:10.33564/ijeast.2020.v04i12.054 · Cited by 1,197 · cited 1×
“The FNN models are a kind of arti fi cial neural networks based on neurons that receive an input signal and process them by the activation function to an output signal (Svozil et al., 1997; Sharma et al., 2017).”
Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870 · cited 1×
“To identify the foot contact in the IMU data (inputs of the model) we have made use of the hip acceleration (Zijlstra and Hof, 2003).”
MethodIMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867 · cited 2×
“was used to estimate the joint angles by means of the accelerometer and gyroscope data provided by the sensors (Seel et al., 2014).”
MethodOverfitting and undercomputing in machine learning
Dietterich, T. (1995) · ACM Computing Surveys · doi:10.1145/212094.212114 · Cited by 757 · cited 2×
“It is usual to obtain an increase in the error with inter-participant data, but the behavior of the RF models might indicate that they tend to overfit more than the FNN models, which is a known problem on algorithms based on decision trees (Dietterich, 1995).”
MethodEnsemble Machine Learning: Methods and Applications
(2012) · doi:10.1007/978-1-4419-9326-7 · Cited by 746
Determining the initial states in forward-backward filtering
Gustafsson, F. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.492552 · Cited by 479 · cited 1×
“Once the hip, knee, and ankle angles were computed, we applied a forward-backward low-pass fi lter (Gustafsson, 1996) with a 6 Hz cutoff and we obtain the angular velocities of each joint.”
MethodKolmogorov–Smirnov Test: Overview
Berger, V. W., & Zhou, Y. (2014) · Wiley StatsRef: Statistics Reference Online · doi:10.1002/9781118445112.stat06558 · Cited by 471
Approximate solution of the trust region problem by minimization over two-dimensional subspaces
Byrd, R. H., Schnabel, R. B., & Shultz, G. A. (1988) · Mathematical Programming · doi:10.1007/bf01580735 · Cited by 411
Remarks on Zeros and Ties in the Wilcoxon Signed Rank Procedures
Pratt, J. W. (1959) · Journal of the American Statistical Association · doi:10.1080/01621459.1959.10501526 · Cited by 336 · cited 1×
“In the post hoc analysis, pairwise comparisons have been studied by the Wilcoxon signed-rank test with the zero method proposed by Pratt (1959).”
MethodSheldon, M. R., Fillyaw, M. J., & Thompson, W. D. (1996) · Physiotherapy Research International · doi:10.1002/pri.66 · Cited by 279 · cited 1×
“The Friedman test was used to study the differences between the accuracy of the models (Sheldon et al., 1996).”
MethodForce treadmill for measuring vertical and horizontal ground reaction forces
Kram, R., Griffin, T. M., Donelan, J. M., & Chang, Y. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.764 · Cited by 239 · cited 1×
“…lower extremity biomechanical analysis, the kinetic data must include the ground reaction forces produced (Lencioni et al., 2019), which can be divided into the mediolateral ground reaction force, the anteroposterior ground reaction force, and the vertical ground reaction force (Kram et al., 1998).”
BackgroundWouda, F. J., Giuberti, M., Bellusci, G., Maartens, E., Reenalda, J., van Beijnum, B.-J. F., & Veltink, P. H. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00218 · Cited by 207 · cited 1×
“F. J. Wouda et al. also used IMU sensors over the lower limbs (pelvis and lower legs) (Wouda et al., 2018).”
MethodPrediction of ground reaction forces during gait based on kinematics and a neural network model
Oh, S. E., Choi, A., & Mun, J. H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.036 · Cited by 192 · cited 2×
“In (Oh et al., 2013) the authors obtained an RMSE of around 0.”
BackgroundMethodLencioni, T., Carpinella, I., Rabuffetti, M., Marzegan, A., & Ferrarin, M. (2019) · Scientific Data · doi:10.1038/s41597-019-0323-z · Cited by 184
Gender differences in trunk, pelvis and lower limb kinematics during a single leg squat
Graci, V., Dillen, L. R. V., & Salsich, G. B. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.006 · Cited by 165 · cited 1×
“Computer vision techniques (Graci et al., 2012), but also wearable inertial sensors (Sy et al.”
BackgroundFineberg, D. B., Asselin, P. K., Harel, N. Y., Agranova-Breyter, I., Kornfeld, S. D., Bauman, W. A., & Spungen, A. M. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000126 · Cited by 145 · cited 1×
“The analysis of human kinematics and kinetics has great potential in the prevention of injuries (Padua and DiStefano, 2009), and the analysis or prediction of musculoskeletal disorders (Fineberg et al., 2013).”
BackgroundSeel, T., Schauer, T., & Raisch, J. (2012) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2012.6402423 · Cited by 132 · cited 1×
“The proposed method is based on the analysis of the movement of the joints and it allows obtaining the joint angles with high accuracy with IMUs even at low acquisition rates (from 40 Hz) (Seel et al., 2012).”
MethodIMU: Inertial sensing of vertical CoM movement
Esser, P., Dawes, H., Collett, J., & Howells, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.049 · Cited by 130 · cited 1×
“To obtain the vertical acceleration we acquired the acceleration and orientation of the IMU placed over the C7 vertebra (Esser et al., 2009).”
MethodAnalysis of the vertical component of force in normal and pathological gait
Jacobs, N. A., Skorecki, J., & Charnley, J. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90016-4 · Cited by 124 · cited 1×
“The vGRF is generated in the sagittal plane and represents the magnitude and pattern of mechanical loading in the vertical direction at the foot (Jacobs et al., 1972).”
BackgroundEstimating Vertical Ground Reaction Force during Walking Using a Single Inertial Sensor
Jiang, X., Napier, C., Hannigan, B. C., Eng, J. J., & Menon, C. (2020) · Sensors · doi:10.3390/s20154345 · Cited by 91 · cited 2×
“X. Jiang et al. used a Random Forest model to estimate the vGRF during gait with a single IMU using acceleration and gyroscope data (Jiang et al., 2020).”
MethodResultInfluentialAnalysis and interpretation of ground reaction forces in normal gait
Marasović, T., Cecić, M., & Zanchi, V. (2009) · Cited by 83
Padua, D. A., & DiStefano, L. J. (2009) · Sports Health A Multidisciplinary Approach · doi:10.1177/1941738108330971 · Cited by 80 · cited 1×
“The analysis of human kinematics and kinetics has great potential in the prevention of injuries (Padua and DiStefano, 2009), and the analysis or prediction of musculoskeletal disorders (Fineberg et al.”
BackgroundGround reaction forces predicted by using artificial neural network during asymmetric movements
Choi, A., Lee, J., & Mun, J. H. (2013) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-013-0064-4 · Cited by 77 · cited 2×
“991 with intra-participants; in (Choi et al., 2013) the authors obtained an RMSE of around 0.”
BackgroundMethodWeber, D. (2016) · BMC Geriatrics · doi:10.1186/s12877-016-0201-x · Cited by 73 · cited 1×
“After the calibration was carried out, the subjects walked over the treadmill at four different speeds selected to cover a wide range of normal gait speeds Weber (2016): 1.5 km/h, 2.5 km/h, 3.5 km/h, and 4.5 km/h.”
MethodInfluentialShahabpoor, E., & Pavić, A. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.08.015 · Cited by 67 · cited 2×
“(Shahabpoor and Pavic, 2018).”
MethodComparison of Orientation Filter Algorithms for Realtime Wireless Inertial Posture Tracking
Young, A. D. (2009) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.25 · Cited by 63 · cited 1×
“We have used a complementary fi lter (Young, 2009) de fi ned as: To obtain fl exion/extension data from the participants, we have used a sample period Δ t = 0.016 (60 Hz) and λ = 0.02.”
MethodInfluentialAmbulatory measurement and analysis of the lower limb 3D posture using wearable sensor system
Liu, K., Liu, T., SHIBATA, K., & INOUE, Y. (2009) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2009.5245982 · Cited by 46 · cited 1×
“mention, by knowing the axis coordinates we can applymethods that need the axes of the sensor coincide with the joint or the segment axes (Liu et al., 2009).”
BackgroundMoya-Angeler, J., Vaquero, J., & Forriol, F. (2017) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-017-0456-9 · Cited by 27 · cited 1×
“On the other hand, when performing a kinetic analysis, the human joint forces and torques are estimated by the forces exerted, using inverse dynamics methods (Moya-Angeler et al., 2017).”
MethodSy, L. W., Lovell, N. H., & Redmond, S. J. (2020) · Sensors · doi:10.3390/s20236829 · Cited by 25 · cited 1×
“Computer vision techniques (Graci et al., 2012), but also wearable inertial sensors (Sy et al., 2020) can be used for estimating the angle of the human limbs.”
EVALUATION OF GROUND REACTION FORCES IN PATIENTS WITH VARIOUS SEVERITIES OF KNEE OSTEOARTHRITIS
Shafizadegan, Z., Karimi, M. T., Shafizadegan, F., & Rezaeian, Z. S. (2015) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519416500032 · Cited by 17 · cited 1×
“For this reason, the analysis of vGRF characteristic peaks could be essential to study musculoskeletal disorders (Shafizadegan et al., 2016).”
BackgroundTowards a portable human gait analysis & monitoring system
Kumar, S., Gopinath, K., Rocchi, L., Sukumar, P. T., Kulkarni, S., & Sampath, J. S. (2018) · IEEE International Conference on Signals and Systems (ICSigSys) · doi:10.1109/icsigsys.2018.8372660 · Cited by 11 · cited 2×
“The method proposed by T. Seel et al. has shown a root mean squared error (RMSE) of between 3 and 5 ° for the hip, knee, and ankle fl exion/extension movements (Kumar et al., 2018).”
BackgroundMethod
Research works printed but not linked: 1
- Gulli A. Pal S. (2017). Deep learning with Keras. Birmingham: Packt Publishing Ltd.
Cited by
Multibody dynamics-based musculoskeletal modeling for gait analysis: a systematic review
Abdullah, M., Hulleck, A. A., Katmah, R., Khalaf, K. A., & Rich, M. E. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01458-y · Cited by 66
Yamaguchi, T., Takahashi, Y., & Sasaki, Y. (2023) · Sensors · doi:10.3390/s23218985 · Cited by 21
Martínez-Pascual, D., Catalan, J. M., Blanco, A., Sanchís, M., Arán‐Aís, F., & García-Aracil, N. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3400296 · Cited by 19
“2, which is based on previous studies [38], [39].”
BackgroundSelf-citationChen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Liu, Y., Liu, R., Wan, X., Chen, C., Wang, Y., Yu, W., Ouyang, J., Qian, L., & Liu, G. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3451651 · Cited by 7
“Key indicators comprised the first (GRF-F) during the loading response (LR) phase and the second peak of GRF (GRF-S) during the terminal stance (Tst) phase [40].”
Background
Metadata
- Authors
- Martínez-Pascual, D., Catalán, J. M., Blanco-Ivorra, A., Sanchís, M., Arán-Ais, F., & García-Aracil, N.
- Affiliations
- Universitat de Miguel Hernández d'Elx (ES)
- Instituto Tecnológico del Calzado y Conexas (ES)
- Corresponding author
- Martínez-Pascual, David
- Venue
- Frontiers in Bioengineering and Biotechnology
- Publisher
- Frontiers Media SA
- Published
- 2023-09-29
- Volume
- 11
- Pages
- 1199459-1199459
- ISSN
- 2296-4185 (ISSN-L)
- PMC
- PMC10570513
- OpenAlex
- W4387166321
- Cited by
- 21
- References
- 37
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 4 · 2023: 1
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Bioengineering and Biotechnology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- European Commission
- Ministerio de Ciencia e Innovación
- Ministerio de Universidades
- NextGenerationEU
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- vertical ground reaction force, gait analysis, wearable inertial sensors, inertial measurement unit, lower limb kinematics, vertical acceleration, force estimation, feedforward neural networks, random forest, feature importance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.