Recent Advances in Non-Enzymatic Glucose Sensors Based on Metal and Metal Oxide Nanostructures for Diabetes Management- A Review
Open accessThe DOI matches its Crossref record; 139 of the 139 references it cites were found in a registry or an index.
Abstract
There is an undeniable growing number of diabetes cases worldwide that have received widespread global attention by many pharmaceutical and clinical industries to develop better functioning glucose sensing devices. This has called for an unprecedented demand to develop highly efficient, stable, selective, and sensitive non-enzymatic glucose sensors (NEGS). Interestingly, many novel materials have shown the promising potential of directly detecting glucose in the blood and fluids. This review exclusively encompasses the electrochemical detection of glucose and its mechanism based on various metal-based materials such as cobalt (Co), nickel (Ni), zinc (Zn), copper (Cu), iron (Fe), manganese (Mn), titanium (Ti), iridium (Ir), and rhodium (Rh). Multiple aspects of these metals and their oxides were explored vis-à-vis their performance in glucose detection. The direct glucose oxidation via metallic redox centres is explained by the chemisorption model and the incipient hydrous oxide/adatom mediator (IHOAM) model. The glucose electrooxidation reactions on the electrode surface were elucidated by equations. Furthermore, it was explored that an effective detection of glucose depends on the aspect ratio, surface morphology, active sites, structures, and catalytic activity of nanomaterials, which plays an indispensable role in designing efficient NEGS. The challenges and possible solutions for advancing NEGS have been summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Combining theory and experiment in electrocatalysis: Insights into materials design
Seh, Z. W., Kibsgaard, J., Dickens, C. F., Chorkendorff, I., Nørskov, J. K., & Jaramillo, T. F. (2017) · Science · doi:10.1126/science.aad4998 · Cited by 12,114 · cited 1×
“A method that involves the adsorption and desorption of reactants on the electrode is referred to as chemisorption model (Toghill and Compton, 2010; Seh et al., 2017).”
MethodElectrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 1×
“The lack of enzymes confer them better stability and leaves them unaffected by external conditions like pH, temperature, ionic strength (Wang, 2008; Popov et al., 2021).”
BackgroundRecent Progress in Cobalt‐Based Heterogeneous Catalysts for Electrochemical Water Splitting
Wang, J., Cui, W., Liu, Q., Xing, Z., Asiri, A. M., & Sun, X. (2016) · Advanced Materials · doi:10.1002/adma.201502696 · Cited by 2,446
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881 · cited 1×
“To overcome this challenging increase in diabetes, the scientific community needs to make enormous efforts to develop highly efficient, easily accessible, stable NEG sensors to monitor the glucose level at the early stages of diabetes (Teymourian et al., 2020).”
BackgroundRecent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788 · cited 3×
“However, these advanced materials are mostly inorganic nanoparticles (NPs) (Hwang et al., 2018), nanosheets (Joshna et al.”
BackgroundGlucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777 · cited 1×
“EG sensors possess high specific catalytic action and efficiency, besides their excellent selectivity, sensitivity, andmild measurement conditions (Bruen et al., 2017).”
BackgroundHydrogen Evolution and Oxidation: Mechanistic Studies and Material Advances
Tian, X., Zhao, P., & Sheng, W. (2019) · Advanced Materials · doi:10.1002/adma.201808066 · Cited by 751 · cited 1×
“Simultaneously, reactive OHads pre-monolayer with a low lattice coordination value is created on the electrode surface and mediates different redox reactions (Tian et al., 2019).”
BackgroundElectrospun Co3O4 nanofibers for sensitive and selective glucose detection
Ding, Y., Wang, Y., Su, L., Bellagamba, M., Zhang, H., & Lei, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.050 · Cited by 707
Strain engineering of metal-based nanomaterials for energy electrocatalysis
Xia, Z., & Guo, S. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00846a · Cited by 675 · cited 1×
“Subsequently, when electrooxidation of adsorbents occurs, gluconolactone is oxidized to gluconic acid via several pHdependent reaction routes (de Mele et al., 1982; Beden et al., 1996; Li et al., 2018; Xia and Guo, 2019).”
BackgroundNon-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Cited by
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Metadata
- Authors
- Naikoo, G. A., Salim, H., Hassan, I. U., Awan, T., Arshad, F., Pedram, M. Z., Ahmed, W., & Qurashi, A.
- Venue
- Frontiers in Chemistry
- Publisher
- Frontiers Media SA
- Published
- 2021-09-22
- Volume
- 9
- Pages
- 748957-748957
- ISSN
- 2296-2646 (ISSN-L)
- OpenAlex
- W3200380336
- Cited by
- 181
- References
- 139
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.