The DOI matches its Crossref record.
Mid-infrared optical coherence tomography and machine learning for inspection of 3D-printed ceramics at the micron scale
Abstract
Introduction: In this paper, recent developments in non-destructive testing of 3D-printed ceramics and monitoring of additive manufacturing of ceramics are presented. Methods: In particular, we present the design and use of an inline mid-infrared optical coherence tomography (MIR-OCT) system to evaluate printed and micro-structured specimens in lithography-based ceramic manufacturing (LCM). Results: The proposed system helps with the detection of microdefects (e.g., voids, inclusions, deformations) that are already present in green ceramic components, thereby reducing the energy and costs incurred. Discussion: The challenges during integration are discussed. Especially, the prospects for MIR-OCT imaging combined with machine learning are illustrated with regard to inline inspection during LCM of printed ceramics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“OCT supports the real-time monitoring of biomass, void fraction and porosity, roughness, and shear-induced detachment on medical materials and industrial lines.”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [242]
In the citing paper
“Bioluminescence platforms can be paired with OCT to obtain structure-linked viable load readouts or machine learning (ML) based texture scoring over time.”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [242]
In the citing paper
“It is label-free, depth-resolved, and rapid.”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [242]
In the citing paper
“Mid infrared (mid IR) and frequency domain OCT (FD OCT) provide better contrast in soft, water-rich materials [240,241,242].”
From Understanding Pseudomonas aeruginosa Biofilms: Quorum Sensing, c-di-GMP Signaling, and Emerging Antibiofilm Approaches (2026) · cites this paper as [242]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 25
- Abdelkader, 2024, Ceramics 3D printing: a comprehensive overview and applications, with brief insights into industry and market, Ceramics, 7, 68, 10.3390/ceramics7010006 · DOI
- Buj-Corral, 2022, 3D printing of bioinert oxide ceramics for medical applications, J. Funct. Biomater., 13, 155, 10.3390/jfb13030155 · DOI
- Chen, 2019, 3D printing of ceramics: a review, J. Eur. Ceram. Soc., 39, 661, 10.1016/j.jeurceramsoc.2018.11.013 · DOI · Paper page
- del Amor, 2020, Automatic segmentation of epidermis and hair follicles in optical coherence tomography images of normal skin by convolutional neural networks, Front. Med., 7, 220, 10.3389/fmed.2020.00220 · doi:10.3389/fmed.2020.00220
- Harrer, 2017, Fractography of zirconia-specimens made using additive manufacturing (LCM) technology, J. Eur. Ceram. Soc. C, 37, 4331, 10.1016/j.jeurceramsoc.2017.03.018 · DOI
- He, 2009, Learning from imbalanced data, IEEE Trans. Knowl. Data Eng., 21, 1263, 10.1109/TKDE.2008.239 · DOI · Paper page
- He, 2021, Progress and challenges towards additive manufacturing of SiC ceramic, J. Adv. Ceram., 10, 637, 10.1007/s40145-021-0484-z · DOI · Paper page
- Heise, 2020, Optical coherence tomography in nondestructive testing, 37, 10.1117/12.2556832 · doi:10.1117/12.2556832
- Israelsen, 2019, Real-time high-resolution mid-infrared optical coherence tomography, Light Sci. and Appl., 8, 11, 10.1038/s41377-019-0122-5 · DOI · Paper page
- Jang, 2023, All-dielectric terahertz metalens using 3D-printing, Opt. Lasers Eng., 171, 107834, 10.1016/j.optlaseng.2023.107834 · DOI
- Kollenberg, 2017, Technische keramik
- Kopycinska-Müller, 2023, Signal-decay based approach for visualization of buried defects in 3-D printed ceramic components imaged with help of optical coherence tomography, Materials, 16, 3607, 10.3390/ma16103607 · doi:10.3390/ma16103607
- Lee, 2016, Deep learning is effective for the classification of OCT images of normal versus Age-related Macular Degeneration, BioRxiv, 094276, 10.1101/094276 · DOI
- Ly, 2022, 3D printing of ceramic biomaterials, Eng. Regen., 3, 41, 10.1016/j.engreg.2022.01.006 · DOI
- Nohut, 2023, 3D-printed alumina-based ceramics with spatially resolved porosity, Int. J. Appl. Ceram. Technol., 21, 89, 10.1111/ijac.14512 · doi:10.1111/ijac.14512
- Ramírez, 2023, Review on additive manufacturing and non-destructive testing, J. Manuf. Syst., 66, 260, 10.1016/j.jmsy.2022.12.005 · DOI · Paper page
- Schwentenwein, 2015, Additive manufacturing of dense alumina ceramics, Int. J. Appl. Ceram., 12, 1, 10.1111/ijac.12319 · DOI · Paper page
- Senthooran, 2024, Enhancing mechanical and thermal properties of 3D-printed samples using mica-epoxy acrylate resin composites—via digital light processing (DLP), Polymers, 16, 1148, 10.3390/polym16081148 · doi:10.3390/polym16081148
- Stampfl, 2023, Lithography-based additive manufacturing of ceramics: materials, applications and perspectives, MRS Commun., 13, 786, 10.1557/s43579-023-00444-0 · doi:10.1557/s43579-023-00444-0
- Su, 2014, Perspectives of mid-infrared optical coherence tomography for inspection and micrometrology of industrial ceramics, Opt. Express, 22, 15804, 10.1364/OE.22.015804 · doi:10.1364/oe.22.015804
- Sun, 2008, Optical methods for nondestructive evaluation of subsurface flaws in silicon nitride ceramics, Corros. Wear, Fatigue, Reliab. Ceram. Ceram. Eng. Sci. Proc., 29, 181, 10.1002/9780470456347.ch18 · doi:10.1002/9780470456347.ch18
- Wits, 2016, Porosity testing methods for the quality assessment of selective laser melted parts, CIRP Ann., 65, 201, 10.1016/j.cirp.2016.04.054 · DOI · Paper page
- Zorin, 2022, Mid-infrared optical coherence tomography as a method for inspection and quality assurance in ceramics additive manufacturing, Open Ceram., 12, 100311, 10.1016/j.oceram.2022.100311 · DOI
- Zorin, 2020, Dual-band infrared optical coherence tomography using a single supercontinuum source, Opt. Express, 28, 7858, 10.1364/OE.386398 · doi:10.1364/oe.386398
- Zorin, 2018, Mid-infrared Fourier-domain optical coherence tomography with a pyroelectric linear array, Opt. Express, 26, 33428, 10.1364/OE.26.033428 · doi:10.1364/oe.26.033428
Cited by
Elbehiry, A., Marzouk, E., Edrees, H. M., Ibrahem, M., Alzahrani, S., Anagreyyah, S., Abualola, H., Alghamdi, A., Alzahrani, A., Jaber, M., et al. (2026) · Microorganisms · doi:10.3390/microorganisms14010109 · Cited by 34
Metadata
- Authors
- Heise, B., Zorin, I., Duswald, K., Karl, V., Brouczek, D., Eichelseder, J., & Schwentenwein, M.
- Venue
- Frontiers in Materials
- Publisher
- Frontiers Media SA
- Published
- 2024-09-18
- Volume
- 11
- ISSN
- 2296-8016
- Cited by
- 8
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mid-infrared optical coherence tomography and machine learning for inspection of 3D-printed ceramics at the micron scale. https://app.cochat.ai/papers/10.3389/fmats.2024.1441812
- The paper
- Heise, B., Zorin, I., Duswald, K., Karl, V., Brouczek, D., Eichelseder, J., & Schwentenwein, M. (2024). Mid-infrared optical coherence tomography and machine learning for inspection of 3D-printed ceramics at the micron scale. Frontiers in Materials. https://doi.org/10.3389/fmats.2024.1441812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.