A Novel Method for Measuring the Pupil Diameter and Pupillary Light Reflex of Healthy Volunteers and Patients With Intracranial Lesions Using a Newly Developed Pupilometer

Kotani, Joji, Nakao, Hiroyuki, Yamada, Isamu, Miyawaki, Atsushi, Mambo, Naomi, Ono, Yuko · 2021 · Frontiers in Medicine
Cited by 9

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Physicians currently measure the pupil diameter and the pupillary light reflex with visual observations using a ruler and a traditional penlight, leading to possibly inaccurate and subjective assessments. Although a mobile pupillometer has been developed and is available in clinical settings, this device can only assess one pupil at a time. Hence, an indirect pupillary light reflex, including those under irradiation to the opposite side of pupil, cannot be evaluated. Consequently, we have developed a new automatic mobile pupilometer, the Hitomiru®, with Hitomiru Co., Ltd. (Tokyo, Japan). This device is a two-glass type pupilometer with a video recording system. The pupil diameter and light reflex of both pupils can be measured simultaneously; therefore, both indirect and direct light reflexes can be assessed. Purpose: To evaluate the clinical ability of the Hitomiru® pupilometer to assess the pupil diameter and the pupillary light reflex of healthy volunteers and patients with intracranial lesions in an intensive care unit (ICU). Methods: Twenty-five healthy volunteers and five ICU patients with intracranial lesions on only the left side were assessed using the Hitomiru® pupilometer. The protocol was as follows: infrared light was applied to both pupils, followed by visible light to the right pupil, infrared light to both pupils, visible light to the left pupil, and then infrared light to both pupils. All the intervals were 2 s, and the dynamics of pupil diameters on both sides were continuously recorded. Results: The healthy adults had approximately 0.5 mm anisocoria, miosis was harder, and mydriasis was less with increased age. There were several differences in miosis rates, miosis times, and mydriasis rates between the healthy adults and the patients with intracranial lesions with both direct irradiation and indirect irradiation. Conclusions: The initial trial estimated and digitally recorded direct and indirect light reflexes, including rapidity of miosis after direct and indirect lights on, and mydriasis after direct and indirect lights off. The Hitomiru® pupilometer was a useful device to digitally record and investigate the relationship between pupil reflexes and intracranial diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fmed.2021.598791

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 15

  1. Larson, 1995, Pupillometric analysis of the 'absent light reflex', Arch Neurol., 52, 369, 10.1001/archneur.1995.00540280051018 · DOI
  2. Wilson, 1907, Ectopia pupilliae in certain mesencephalic lesions, Brain., 29, 524, 10.1093/brain/29.4.524 · doi:10.1093/brain/29.4.524
  3. Zafar, 2014, Automated pupillometer for monitoring the critically ill patient: a critical appraisal, J Crit Care., 29, 599, 10.1016/j.jcrc.2014.01.012 · DOI
  4. Taylor, 2003, Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury, J Neurosurg., 98, 205, 10.3171/jns.2003.98.1.0205 · DOI
  5. Manley, 2002, Infrared pupillometry during uncal herniation, J Neurosurg Anesthesiol., 14, 223, 10.1097/00008506-200207000-00009 · doi:10.1097/00008506-200207000-00009
  6. Meeker, 2005, Pupil examination: validity and clinical utility of an automated pupillometer, J Neurosci Nurs., 37, 34, 10.1097/01376517-200502000-00006 · doi:10.1097/01376517-200502000-00006
  7. Yan, 2009, Clinical utility of an automated pupillometer for assessing and monitoring recipients of liver transplantation, Liver Transpl., 15, 1718, 10.1002/lt.21924 · doi:10.1002/lt.21924
  8. Behrends, 2012, Infrared pupillometry to detect the light reflex during cardiopulmonary resuscitation: a case series, Resuscitation., 83, 1223, 10.1016/j.resuscitation.2012.05.013 · DOI
  9. Gray, 1997, Neuromuscular blocking drugs do not alter the pupillary light reflex of anesthetized humans, Arch Neurol., 54, 579, 10.1001/archneur.1997.00550170055014 · doi:10.1001/archneur.1997.00550170055014
  10. Yoshitomi, 1985, Adrenergic excitatory and cholinergic inhibitory innervations in the human iris dilator, Exp Eye Res., 40453, 10.1016/0014-4835(85)90158-7 · DOI
  11. 2000, The American Association of Neurological Surgeons. The Joint Section on Neurotrauma and Critical Care. Pupillary diameter and light reflex, J Neurotrauma, 17, 583, 10.1089/neu.2000.17.583 · DOI
  12. Murray, 1981, Infrared video pupillometry: a method used to measure the pupillary effects of drugs in small laboratory animals in real time, J Neurosci Methods., 3, 365, 10.1016/0165-0270(81)90024-8 · DOI
  13. Lam, 1987, The prevalence of simple anisocoria, Am J Ophthalmol., 104, 69, 10.1016/0002-9394(87)90296-0 · doi:10.1016/0002-9394(87)90296-0
  14. Caird, 1973, Effect of posture on blood pressure in the elderly, Br Heart, J., 35, 527, 10.1136/hrt.35.5.527 · DOI · Paper page
  15. Collins, 1980, Functional changes in autonomic nervous responses with ageing, Age Ageing., 9, 17, 10.1093/ageing/9.1.17 · DOI

Cited by

See all 9

Metadata

Authors
Kotani, J., Nakao, H., Yamada, I., Miyawaki, A., Mambo, N., & Ono, Y.
Venue
Frontiers in Medicine
Published
2021-09-07
Volume
8
ISSN
2296-858X
Cited by
9
References
1

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Method for Measuring the Pupil Diameter and Pupillary Light Reflex of Healthy Volunteers and Patients With Intracranial Lesions Using a Newly Developed Pupilometer. https://app.cochat.ai/papers/10.3389/fmed.2021.598791
The paper
Kotani, J., Nakao, H., Yamada, I., Miyawaki, A., Mambo, N., & Ono, Y. (2021). A Novel Method for Measuring the Pupil Diameter and Pupillary Light Reflex of Healthy Volunteers and Patients With Intracranial Lesions Using a Newly Developed Pupilometer. Frontiers in Medicine. https://doi.org/10.3389/fmed.2021.598791

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.