Changes in Autonomic Function with Age: A Study of Pupillary Kinetics in Healthy Young and Old People
Abstract
The object of the study was to compare resting pupil diameter in darkness and light, and the pupillary darkness and light reflexes between a group of young and elderly healthy subjects. Twelve young (eight men, four women; median age 19.5 years) and 14 elderly subjects (six men, eight women; median age 69 years) participated. Pupil diameter was monitored with an infra-red television pupillometer. Resting pupil size was measured in light (16 and 32 Cd m-2) and in darkness. The darkness reflex was elicited by switching off the ambient illumination (16 Cd m-2) for 1 s. The light reflex was elicited in darkness by short (200 ms) pulses of green (peak wavelength 565 nm) light at four ascending stimulus intensities (8.5 x 10(-3), 7.0 x 10(-2), 0.43 and 1.84 mW cm-2). The amplitude (mm) and maximum velocity (mm s-1) of the darkness reflex and the latency (ms), amplitude (mm), maximum constriction velocity (mm s-1) and 75% recovery time (s) of the light reflex were measured. The resting pupil diameter was found to be smaller in the elderly group at all three illumination levels (p = 0.001). The amplitude and maximum dilatation velocity of the darkness reflex were smaller for the elderly group (p = 0.001). The amplitude of the light reflex at the three highest light intensities and maximum constriction velocity at all light intensities were smaller in the elderly group (p = 0.002). Seventy-five per cent recovery time was longer in the elderly group (p = 0.02). There was no difference in the latency of the light reflex response between the two groups. The reduced pupil size, diminished darkness reflex amplitude and velocity, and prolonged recovery time of light reflex are consistent with sympathetic deficit in old age. Although the reductions in light reflex amplitude and constriction velocity in the elderly group at first sight would indicate a parasympathetic deficit in old age, they are more likely to be secondary to the grossly diminished pupil size.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pupil size in humans, both baseline and light-adapted, decreases with age.
“the pupil size (both the baseline and light-adapted pupil size) in humans decreases with age [45,46].”
From Are dark-eyed dogs favoured by humans? Domestication as a potential driver of iris colour difference between dogs and wolves (2023) · cites this paper as [46]
Cites
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130 · see citing works
Evaluation of the Causes and Accuracy of Pharmacologic Localization in Horner's Syndrome
Maloney, W. F., Younge, B. R., & Moyer, N. J. (1980) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)74924-4 · Cited by 235 · see citing works
Decline in beta adrenergic receptor-mediated vascular relaxation with aging in man.
Pan, H. Y., Hoffman, B. B., Pershe, R., & Blaschke, T. F. (1986) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)23354-7 · Cited by 186 · see citing works
Korkushko, O. V., Shatilo, V. B., Plachinda, Y. I., & ShatiloShatilo, T. V. (1991) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(91)90113-h · Cited by 125 · see citing works
Codon-restriction theory of aging and development
Strehler, B. L., Hirsch, G. P., Gusseck, D. J., Johnson, R. W., & Bick, M. D. (1971) · Journal of Theoretical Biology · doi:10.1016/0022-5193(71)90091-9 · Cited by 124 · see citing works
Evidence for a neuropathic aetiology in the small pupil of diabetes mellitus.
Smith, S. A., & Smith, S. E. P. (1983) · British Journal of Ophthalmology · doi:10.1136/bjo.67.2.89 · Cited by 97 · see citing works
The Cell Biology of Human Aging
Hayflick, L. (1980) · Scientific American · doi:10.1038/scientificamerican0180-58 · Cited by 89 · see citing works
A Simple Diagnostic Test for Pupillary Abnormality in Diabetic Autonomic Neuropathy
Smith, S. A., & Dewhirst, R. R. (1986) · Diabetic Medicine · doi:10.1111/j.1464-5491.1986.tb00703.x · Cited by 86 · see citing works
Hydroxyamphetamine Mydriasis in Horner's Syndrome
Cremer, S. A., Thompson, H. S., Digre, K. B., et al. (1990) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)76941-7 · Cited by 77 · see citing works
Iris Mechanics I. Influence of Pupil Size on Dynamics of Pupillary Movements
Loewenfeld, I. E., & Newsome, D. A. (1971) · American Journal of Ophthalmology · doi:10.1016/0002-9394(71)90410-7 · Cited by 69 · see citing works
Sympathetic Pupillary Tone in Old Age
Korczyn, A. D., Laor, N., & Nemet, P. (1976) · Archives of Ophthalmology · doi:10.1001/archopht.1976.03910040615006 · Cited by 68 · see citing works
Adrenoceptor Function and Ageing
Kelly, J. G., & O'MALLEY, K. (1984) · Clinical Science · doi:10.1042/cs0660509 · Cited by 59 · see citing works
The localization of pupilloconstrictor function within the mid‐brain of the cat
Sillito, A. M., & Zbrożyna, A. W. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009287 · Cited by 53 · see citing works
AGE AND SEX DIFFERENCES IN SPONTANEOUS, ADRENERGIC AND CHOLINERGIC HUMAN SWEATING.
SIVER, A., Montagna, W., & KARACAN, I. (1964) · PubMed · Cited by 31 · see citing works
Midbrain Single Units Correlating with Pupil Response to Light
Smith, J. D. S., Ichinose, L. Y., Masek, G. A., et al. (1968) · Science · doi:10.1126/science.162.3859.1302 · Cited by 31 · see citing works
THE ACTIVITY OF THE CILIO-SPINAL CENTERS AND THEIR INHIBITION IN PUPILLARY LIGHT REFLEX
Nisida, I., Okada, H., & Nakano, O. (1960) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.10.73 · Cited by 27 · see citing works
Morley, M. J., Bradshaw, C. M., & Szabadi, E. (1991) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1991.tb03864.x · Cited by 26 · see citing works
Self-citationÜber hyaline Degeneration des Pupillarrandes
Meller, J. (1904) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf01995294 · Cited by 19 · see citing works
The responsiveness of human eccrine sweat glands to choline and carbachol
Lamb, K., Bradshaw, C. M., & Szabadi, E. (1983) · European Journal of Clinical Pharmacology · doi:10.1007/bf00613927 · Cited by 18 · see citing works
Self-citationPupil constriction and visual evoked potential latency in optic neuritis
Bos, J. E., Fock, J., Reulen, J. P. H., & van Lith, G. H. M. (1990) · Neuro-Ophthalmology · doi:10.3109/01658109008997281 · Cited by 14 · see citing works
Pr, B., Sa, S., & Smith, S. E. (1979) · PubMed · Cited by 10 · see citing works
Szabadi, E. (1977) · PubMed · Cited by 9 · see citing works
Self-citationConsensual pupillary responses to mydriatic and miotic drugs.
Theofilopoulos, N., Longmore, J., Kerr, F., et al. (1988) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1988.tb05307.x · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Memory load and the cognitive pupillary response in aging
Van Gerven, P. W. M., Paas, F., Van Merriënboer, J. J. G., & Schmidt, H. G. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00148.x · Cited by 292 · see citing works
Individual differences in light sensitivity affect sleep and circadian rhythms
Chellappa, S. L. (2021) · Sleep · doi:10.1093/sleep/zsaa214 · Cited by 163 · see citing works
The role of pupil size in communication. Is there room for learning?
Kret, M. E. (2018) · Cognition and Emotion · doi:10.1080/02699931.2017.1370417 · Cited by 74 · see citing works
Neurologic examination in the elderly
(2019) · Handbook of Clinical Neurology · doi:10.1016/b978-0-12-804766-8.00005-4 · Cited by 33 · see citing works
Impact of age on human non-visual responses to light
REVELL, V. L., & SKENE, D. J. (2010) · Sleep and Biological Rhythms · doi:10.1111/j.1479-8425.2009.00418.x · Cited by 31 · see citing works
Comparison of visual performance with an aspheric intraocular lens and a spherical intraocular lens
Thiagarajan, M., McClenaghan, R., & Anderson, D. F. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.05.046 · Cited by 19 · see citing works
The Effect of Baby Schema in Cats on Length of Stay in an Irish Animal Shelter
Jack, S., & Carroll, G. A. (2022) · Animals · doi:10.3390/ani12111461 · Cited by 7 · see citing works
Konno, A., Aoki, H., Suzuki, E., Furuta, S., & Ueda, S. (2023) · Royal Society Open Science · doi:10.1098/rsos.230854 · Cited by 7 · see citing works
“One possibility comes from that humans may estimate a person ’ s age based on pupil diameter since the pupil size (both the baseline and light-adapted pupil size) in humans decreases with age [45,46].”
Background
- Authors
- BITSIOS, P., PRETTYMAN, R., & SZABADI, E.
- Affiliations
- University of Nottingham (GB)
- Corresponding author
- SZABADI, E.
- Venue
- Age and Ageing
- Publisher
- Oxford University Press (OUP)
- Published
- 1996
- Volume
- 25
- Issue
- 6
- Pages
- 432-438
- ISSN
- 0002-0729 (ISSN-L)
- 1468-2834
- OpenAlex
- W2147799622
- Cited by
- 218
- References
- 23
- Citations by year
- 2026: 15 · 2025: 12 · 2024: 18 · 2023: 14 · 2022: 14 · 2021: 17 · 2020: 11 · 2019: 8 · 2018: 14 · 2017: 6 · 2016: 7 · 2015: 7 · 2014: 12 · 2013: 7 · 2012: 6
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Age and Ageing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- State Scholarships Foundation
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Keywords
- aging, autonomic function, light reflex, pupil size, pupillometry
- MeSH terms
- Adult, Aged, Aging, Autonomic Nervous System, Dark Adaptation, Female, Humans, Male, Middle Aged, Pulse, Reaction Time, Reference Values, Reflex, Pupillary, Geriatric Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review