Reduced discomfort during high-definition transcutaneous stimulation using 6% benzocaine
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: High-Definition transcranial Direct Current Stimulation (HD-tDCS) allows for non-invasive neuromodulation using an array of compact (approximately 1 cm(2) contact area) "High-Definition" (HD) electrodes, as compared to conventional tDCS (which uses two large pads that are approximately 35 cm(2)). In a previous transcutaneous study, we developed and validated designs for HD electrodes that reduce discomfort over >20 min session with 2 mA electrode current. OBJECTIVE: The purpose of this study was to investigate the use of a chemical pretreatment with 6% benzocaine (topical numbing agent) to further reduce subjective discomfort during transcutaneous stimulation and to allow for better sham controlled studies. METHODS: Pre-treatment with 6% benzocaine was compared with control (no pretreatment) for 22 min 2 mA of stimulation, with either CCNY-4 or Lectron II electroconductive gel, for both cathodal and anodal transcutaneous (forearm) stimulation (eight different combinations). RESULTS: RESULTS show that for all conditions and polarities tested, stimulation with HD electrodes is safe and well tolerated and that pretreatment further reduced subjective discomfort. CONCLUSION: Pretreatment with a mild analgesic reduces discomfort during HD-tDCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of depression with transcranial direct current stimulation (tDCS): A Review
Nitsche, M. A., Boggio, P. S., Fregni, F., & Pascual-Leone, A. (2009) · Experimental Neurology · doi:10.1016/j.expneurol.2009.03.038 · Cited by 498
Cited by
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationJamil, A., Batsikadze, G., Kuo, H., Labruna, L., Hasan, A., Paulus, W., & Nitsche, M. A. (2017) · The Journal of Physiology · doi:10.1113/jp272738 · Cited by 397
Adverse events of tDCS and tACS: A review
Matsumoto, H., & Ugawa, Y. (2017) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2016.12.003 · Cited by 349
Mosayebi Samani, M., Agboada, D., Jamil, A., Kuo, M.-F., & Nitsche, M. A. (2019) · Cortex · doi:10.1016/j.cortex.2019.04.016 · Cited by 175
Transcranial direct current stimulation in psychiatric disorders
Tortella, G. (2015) · World Journal of Psychiatry · doi:10.5498/wjp.v5.i1.88 · Cited by 154
Salehinejad, M. A., Nejati, V., Mosayebi-Samani, M., Mohammadi, A., Wischnewski, M., Kuo, M.-F., Avenanti, A., Vicario, C. M., & Nitsche, M. A. (2020) · Neuroscience Bulletin · doi:10.1007/s12264-020-00501-x · Cited by 118
Turner, C., Jackson, C., & Learmonth, G. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.15018 · Cited by 37
Metadata
- Authors
- Guleyupoglu, B., Febles, N., Minhas, P., Hahn, C., & Bikson, M.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2014-07-11
- Volume
- 7
- Pages
- 28-28
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2161936608
- Cited by
- 49
- References
- 1
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.