A tactile P300 brain-computer interface
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
In this study, we investigated a Brain-Computer Interface (BCI) based on EEG responses to vibro-tactile stimuli around the waist. P300 BCIs based on tactile stimuli have the advantage of not taxing the visual or auditory system and of being potentially unnoticeable to other people. A tactile BCI could be especially suitable for patients whose vision or eye movements are impaired. In Experiment 1, we investigated its feasibility and the effect of the number of equally spaced tactors. Whereas a large number of tactors is expected to enhance the P300 amplitude since the target will be less frequent, it could also negatively affect the P300 since it will be difficult to identify the target when tactor density increases. Participants were asked to attend to the vibrations of a target tactor, embedded within a stream of distracters. The number of tactors was two, four or six. We demonstrated the feasibility of a tactile P300 BCI. We did not find a difference in SWLDA classification performance between the different numbers of tactors. In a second set of experiments we reduced the stimulus onset asynchrony (SOA) by shortening the on- and/or off-time of the tactors. The SOA for an optimum performance as measured in our experiments turned out to be close to conventional SOAs of visual P300 BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two new Later Stone Age sites from the Final Pleistocene in the Falémé Valley, eastern Senegal
Ndiaye, M., Lespez, L., Tribolo, C., Rassé, M., Hadjas, I., Davidoux, S., Huysecom, É., & Douze, K. (2024) · Monash University Research Portal (Monash University) · doi:10.3929/ethz-b-000667478 · Cited by 23,868
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“Besides classifi cation accuracy, BCI performance can also be expressed in terms of bitrate (Wolpaw et al., 2002; Serby et al., 2005).”
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 5×
“Even though the effects of SOA and target-to-target interval on P300s and classifi cation performance have been studied before (e.g. Farwell and Donchin, 1988; Serby et al., 2005; Allison and Pineda, 2006; Sellers et al., 2006; Martens et al., 2009; Mell et al., 2008), we did not encounter studies…”
InfluentialBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Toward Direct Brain-Computer Communication
Vidal, J. J. (1973) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.02.060173.001105 · Cited by 1,287
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 1×
“A P300-speller could be especially helpful for, and has been tested on paralyzed users (Hoffmann et al., 2008; Nijboer et al., 2008).”
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Gaze-independent brain–computer interfaces based on covert attention and feature attention
Treder, M. S., Schmidt, N. M., & Blankertz, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066003 · Cited by 182
“Lately, significant advances have been made in non-visual modalities using auditory [23–25] or tactile [26] stimulation.”
BackgroundWebster, J. P., Kaushik, M., Bristow, G. C., & McConkey, G. A. (2013) · Journal of Experimental Biology · doi:10.1242/jeb.074716 · Cited by 166
Kaufmann, T., Herweg, A., & Kübler, A. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-7 · Cited by 159
“Brouwer and van Erp [52] investigated how stimulus uncertainty (i.e. the number of stimuli used) and stimulus timing affect classification accuracy and found equal accuracies for two, four and six tactors.”
BackgroundResultInfluentialEffects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
Höhne, J., Holz, E., Staiger-Sälzer, P., Müller, K.-R., Kübler, A., & Tangermann, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104854 · Cited by 85
A multi-signature brain–computer interface: use of transient and steady-state responses
Severens, M., Farquhar, J., Duysens, J., & Desain, P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026005 · Cited by 36
Reichert, C., Tellez Ceja, I. F., Sweeney-Reed, C. M., Heinze, H.-J., Hinrichs, H., & Dürschmid, S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.591777 · Cited by 23
“For this reason, auditory (Kübler et al., 2009; Halder et al., 2010, 2016; Hill et al., 2014) and tactile variants (Brouwer and van Erp, 2010; Jin et al., 2020) of the oddball paradigm have been investigated, with the finding that they provide inferior performance compared to BCIs based on visual…”
Metadata
- Authors
- Brouwer
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 4
- Pages
- 19-19
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2118157988
- Cited by
- 278
- References
- 43
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.