The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Gesture Recognition Using Surface Electromyography and Deep Learning for Prostheses Hand: State-of-the-Art, Challenges, and Future
Open accessAbstract
Amputation of the upper limb brings heavy burden to amputees, reduces their quality of life, and limits their performance in activities of daily life. The realization of natural control for prosthetic hands is crucial to improving the quality of life of amputees. Surface electromyography (sEMG) signal is one of the most widely used biological signals for the prediction of upper limb motor intention, which is an essential element of the control systems of prosthetic hands. The conversion of sEMG signals into effective control signals often requires a lot of computational power and complex process. Existing commercial prosthetic hands can only provide natural control for very few active degrees of freedom. Deep learning (DL) has performed surprisingly well in the development of intelligent systems in recent years. The significant improvement of hardware equipment and the continuous emergence of large data sets of sEMG have also boosted the DL research in sEMG signal processing. DL can effectively improve the accuracy of sEMG pattern recognition and reduce the influence of interference factors. This paper analyzes the applicability and efficiency of DL in sEMG-based gesture recognition and reviews the key techniques of DL-based sEMG pattern recognition for the prosthetic hand, including signal acquisition, signal preprocessing, feature extraction, classification of patterns, post-processing, and performance evaluation. Finally, the current challenges and future prospects in clinical application of these techniques are outlined and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 2×
“These measures are based on Fitts’ law (Fitts, 1954), which is used to measure the prediction model of the target performance of the designed system (Kamavuako et al.”
MethodHow transferable are features in deep neural networks?
Yosinski, J., Clune, J., Bengio, Y., & Lipson, H. (2014) · arXiv · doi:10.48550/arxiv.1411.1792 · Cited by 6,061
Phoneme recognition using time-delay neural networks
Waibel, A., Hanazawa, T., Hinton, G., Shikano, K., & Lang, K. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.21701 · Cited by 2,643
Measurement in Medicine: A Practical Guide
de Vet, H. C. W., Terwee, C. B., Mokkink, L. B., & Knol, D. L. (2011) · doi:10.1017/cbo9780511996214 · Cited by 2,321
Deep learning for sensor-based activity recognition: A survey
Wang, J., Chen, Y., Hao, S., Peng, X., & Hu, L. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.02.010 · Cited by 2,014 · cited 1×
“For conventional machine learning algorithms, there are limitations in processing raw data, because they could not effectively train on inconsistent, noisy, abstract, and highdimensional data (Wang et al., 2019).”
BackgroundA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684 · cited 4×
“Atzori et al. (2016) introduced a modified version of the well-known CNN architecture, called LeNet, to classify an average of 50 hand movements in NinaPro database.”
BackgroundMethodInfluentialQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Cited by
Ni, S., Al-qaness, M. A. A., Hawbani, A., Al-Alimi, D., Abd Elaziz, M., & Ewees, A. A. (2024) · Applied Soft Computing · doi:10.1016/j.asoc.2024.112235 · Cited by 74
Metadata
- Authors
- Li, W., Shi, P., & Yu, H.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2021-04-26
- Volume
- 15
- Pages
- 621885-621885
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W3163487808
- Cited by
- 211
- References
- 17
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gesture Recognition Using Surface Electromyography and Deep Learning for Prostheses Hand: State-of-the-Art, Challenges, and Future. https://app.cochat.ai/papers/10.3389/fnins.2021.621885
- The paper
- Li, W., Shi, P., & Yu, H. (2021). Gesture Recognition Using Surface Electromyography and Deep Learning for Prostheses Hand: State-of-the-Art, Challenges, and Future. Frontiers in Neuroscience. https://doi.org/10.3389/fnins.2021.621885
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.