Radioembolization of Hepatic Lesions from a Radiobiology and Dosimetric Perspective
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Radioembolization (RE) of liver cancer with (90)Y-microspheres has been applied in the last two decades with notable responses and acceptable toxicity. Two types of microspheres are available, glass and resin, the main difference being the activity/sphere. Generally, administered activities are established by empirical methods and differ for the two types. Treatment planning based on dosimetry is a prerogative of few centers, but has notably gained interest, with evidence of predictive power of dosimetry on toxicity, lesion response, and overall survival (OS). Radiobiological correlations between absorbed doses and toxicity to organs at risk, and tumor response, have been obtained in many clinical studies. Dosimetry methods have evolved from the macroscopic approach at the organ level to voxel analysis, providing absorbed dose spatial distributions and dose-volume histograms (DVH). The well-known effects of the external beam radiation therapy (EBRT), such as the volume effect, underlying disease influence, cumulative damage in parallel organs, and different tolerability of re-treatment, have been observed also in RE, identifying in EBRT a foremost reference to compare with. The radiobiological models - normal tissue complication probability and tumor control probability - and/or the style (DVH concepts) used in EBRT are introduced in RE. Moreover, attention has been paid to the intrinsic different activity distribution of resin and glass spheres at the microscopic scale, with dosimetric and radiobiological consequences. Dedicated studies and mathematical models have developed this issue and explain some clinical evidences, e.g., the shift of dose to higher toxicity thresholds using glass as compared to resin spheres. This paper offers a comprehensive review of the literature incident to dosimetry and radiobiological issues in RE, with the aim to summarize the results and to identify the most useful methods and information that should accompany future studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Tolerance of normal tissue to therapeutic irradiation
Emami, B., Lyman, J., Brown, A., Cola, L., Goitein, M., Munzenrider, J. E., Shank, B., Solin, L. J., & Wesson, M. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90171-y · Cited by 4,488 · cited 3×
“(70) derived tolerance values producing a risk of 5% for partial irradiation of the liver, resulting in 35 and 50 Gy for an irradiation volume equal to 2/3 and 1/3 of the whole organ, respectively.”
BackgroundMethodModified RECIST (mRECIST) Assessment for Hepatocellular Carcinoma
Lencioni, R., & Llovet, J. (2010) · Seminars in Liver Disease · doi:10.1055/s-0030-1247132 · Cited by 4,329 · cited 1×
“Dose–responses in tumor was analyzed considering the DVHs (90Y-PET) or the mean absorbed doses (99mTc-MAA-SPECT) in correlation with follow-up imaging or clinical findings (98, 99).”
MethodClinical Management of Hepatocellular Carcinoma. Conclusions of the Barcelona-2000 EASL Conference
Bruix, J., Sherman, M., Llovet, J. M., Beaugrand, M., Lencioni, R., Burroughs, A. K., Christensen, E., Pagliaro, L., Colombo, M., & Rodés, J. (2001) · Journal of Hepatology · doi:10.1016/s0168-8278(01)00130-1 · Cited by 4,089
Use of Normal Tissue Complication Probability Models in the Clinic
Marks, L. B., Yorke, E. D., Jackson, A., Ten Haken, R. K., Constine, L. S., Eisbruch, A., Bentzen, S. M., Nam, J., & Deasy, J. O. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.07.1754 · Cited by 1,826 · cited 1×
“Dose–responses in tumor was analyzed considering the DVHs (90Y-PET) or the mean absorbed doses (99mTc-MAA-SPECT) in correlation with follow-up imaging or clinical findings (98, 99).”
MethodStabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,350
Fitting of normal tissue tolerance data to an analytic function
Burman, C., Kutcher, G. J., Emami, B., & Goitein, M. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90172-z · Cited by 1,249 · cited 14×
“Few models of TCP and NTCP have been reported in literature that are able to predict the clinical outcome of EBRT, confirming that a correlation is possible when based on the LQM.”
BackgroundInfluentialRadiation Dose–Volume Effects in the Lung
Marks, L. B., Bentzen, S. M., Deasy, J. O., Kong, F.-M. (., Bradley, J. D., Vogelius, I. S., El Naqa, I., Hubbs, J. L., Lebesque, J. V., Timmerman, R. D., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.091 · Cited by 1,103
Kutcher, G. J., & Burman, C. (1989) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(89)90972-3 · Cited by 912 · cited 14×
“DVHs are derived, the degree of non-uniformity analyzed (17, 50, 51), and the EUBED, EUD, EQ2 parameters evaluated.”
MethodInfluential
Cited by
Levillain, H., Bagni, O., Deroose, C. M., Dieudonné, A., Gnesin, S., Grosser, O. S., Kappadath, S. C., Kennedy, A., Kokabi, N., Liu, D. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05163-5 · Cited by 254
Self-citationChiesa, C., Mira, M., Maccauro, M., Spreafico, C., Romito, R., Morosi, C., Camerini, T., Carrara, M., Pellizzari, S., Negri, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3068-8 · Cited by 164
“The second novelty of TARE is the attention paid by many studies to its dosimetric aspects, both before the treatment, using the Tc-MAA SPECT images of the simulation session, and after the therapeutic administration, using either (90)Y bremsstrahlung SPECT or (90)Y positron emission tomography (PET) images [6].”
Self-citation
Metadata
- Authors
- Cremonesi, M., Chiesa, C., Strigari, L., Ferrari, M., Botta, F., Guerriero, F., De Cicco, C., Bonomo, G., Orsi, F., Bodei, L., Di Dia, A., Grana, C. M., & Orecchia, R.
- Venue
- Frontiers in Oncology
- Publisher
- Frontiers Media SA
- Published
- 2014-08-19
- Volume
- 4
- Pages
- 210-210
- ISSN
- 2234-943X (ISSN-L)
- OpenAlex
- W2086716158
- Cited by
- 178
- References
- 64
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.