Cited by 25Hemodynamic Monitoring and TherapySepsis Diagnosis and TreatmentOptical Imaging and Spectroscopy Techniques

Assessing the Microcirculation With Handheld Vital Microscopy in Critically Ill Neonates and Children: Evolution of the Technique and Its Potential for Critical Care

Open access
Erdem, Özge, Ince, Can, Tibboel, Dick, Kuiper, Jan Willem·2019·Frontiers in Pediatrics

Abstract

Assuring adequate tissue oxygenation in the critically ill, but still developing child is challenging. Conventional hemodynamic monitoring techniques fall short in assessing tissue oxygenation as these are directed at the macrocirculation and indirect surrogates of tissue oxygenation. The introduction of handheld vital microscopy (HVM) has allowed for the direct visualization of the microcirculation and with this has offered insight into tissue oxygenation on a microcirculatory level. Since its introduction, technical improvements have been made to HVM, to both hardware and software, and guidelines have been developed through expert consensus on image assessment and analysis. Using HVM, the microcirculation of the skin, the buccal mucosa, and the sublingual mucosa of healthy and (critically) ill neonates and children have been visualized and investigated. Yet, integration of HVM in hemodynamic monitoring has been limited due to technical shortcomings. Only superficial microcirculatory beds can be visualized, inter-observer and intra-observer variabilities are not accounted for and image analysis happens offline and is semi-automated and time-consuming. More importantly, patients need to be cooperative or fully sedated to prevent pressure and movement artifacts, which is often not the case in children. Despite these shortcomings, observational research with HVM in neonates and children has revealed the following: (1) age-related developmental changes in the microcirculation, (2) loss of hemodynamic coherence, i.e., microcirculatory disturbances in the presence of a normal macrocirculation and, (3) microcirculatory disturbances which were independently associated with increased mortality risk. Although these observations underline the importance of microcirculatory monitoring, several steps have to be taken before integration in the decision process during critical care can happen. These steps include technological innovations to ease the use of HVM in the pediatric age group, measuring additional functional parameters of microvascular blood flow and integrated automated analysis software. As a next step, reference values for microcirculatory parameters need to be established, while also accounting for developmental changes. Finally, studies on microcirculatory guided therapies are necessary to assess whether the integration of microcirculatory monitoring will actually improve patient outcome. Nevertheless, HVM remains a promising, non-invasive tool to help physicians assure tissue oxygenation in the critically ill child.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fped.2019.00273

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 77 · Cited by 25

Research works printed but not linked: 2

  1. [56]Top AP Microcirculation in Critically Ill Children (Doctoral dissertation) (2011) 35– 41. Retrieved from: http://hdl.handle.net/1765/51630
  2. [59]Buijs EA Critically Ill Children and the Microcirculation: Go with the Flow? (Doctoral dissertation) (2014) 57– 78. Retrieved from: http://hdl.handle.net/1765/51532

Authors
Erdem, Ö., Ince, C., Tibboel, D., & Kuiper, J. W.
Affiliations
Erasmus MC (NL)
Corresponding author
Kuiper, Jan Willem
Venue
Frontiers in Pediatrics
Published
2019-07-09
Volume
7
Pages
273-273
ISSN
2296-2360 (ISSN-L)
OpenAlex
W2951775067
Cited by
25
References
77
Citations by year
2026: 5 · 2025: 1 · 2024: 3 · 2023: 6 · 2022: 5 · 2021: 3 · 2020: 2
FWCI
0.52
Type
journal article
Language
en
Open access
Locations
  • Frontiers in Pediatrics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, other-oa)
  • Pure Amsterdam UMC (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, other-oa)
  • RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Stichting Vrienden van het Sophia (S17-06)
Topics
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
microcirculation, tissue oxygenation, critically ill neonates, critically ill children, hemodynamic monitoring, buccal mucosa, sublingual mucosa, skin microcirculation, microcirculatory disturbances, mortality risk, microvascular blood flow, image analysis software, reference values, pediatric intensive care

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review