A Comprehensive Review of Fluorescence Correlation Spectroscopy
Open accessThe DOI matches its Crossref record; 118 of the 118 references it cites were found in a registry or an index.
Abstract
Fluorescence correlation spectroscopy (FCS) is a powerful technique for quantification of molecular dynamics, and it has been widely applied in diverse fields, e.g., biomedicine, biophysics, and chemistry. By time-correlation of the fluorescence fluctuations induced by molecules diffusing through a focused light, FCS can quantitatively evaluate the concentration, diffusion coefficient, and interaction of the molecules in vitro or in vivo. In this review, the basic principle and implementation of FCS are introduced. Then, the advances of FCS variants are reviewed, covering dual-color FCCS, multi-focus FCS, pair correlation function (pCF), scanning FCS, focus-reduced FCS, SPIM-FCS, and inverse-FCS. Besides, the applications of FCS are demonstrated with the measurement of local concentration, hydrodynamic radius, diffusion coefficient, and the interaction of different molecules. Lastly, a discussion is given by summarizing the pros and cons of different FCS techniques, as well as the outlooks and perspectives of FCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Mobility measurement by analysis of fluorescence photobleaching recovery kinetics
Axelrod, D., Koppel, D. E., Schlessinger, J., Elson, E., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85755-4 · Cited by 2,714
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753 · cited 3×
“For example, Wenger et al. [120] used dualcolor FCCS to study the kinetics of enzymatic cleavage reaction at 2-μM DNA oligonucleotide concentration.”
BackgroundDirect observation of the nanoscale dynamics of membrane lipids in a living cell
Eggeling, C., Ringemann, C., Medda, R., Schwarzmann, G., Sandhoff, K., Polyakova, S., Belov, V. N., Hein, B., von Middendorff, C., Schönle, A., et al. (2009) · Nature · doi:10.1038/nature07596 · Cited by 1,520 · cited 1×
“[98] applied STEDFCS to the study of living cell membranes, and proved that STEDFCS is capable of detecting the anomalous or heterogeneous diffusion in the membrane [75, 99].”
MethodFluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Single particle tracking. Analysis of diffusion and flow in two-dimensional systems
Qian, H., Sheetz, M. P., & Elson, E. L. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82125-7 · Cited by 1,174
Microscopy and its focal switch
Hell, S. W. (2009) · Nature Methods · doi:10.1038/nmeth.1291 · Cited by 986
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959 · cited 1×
“[79, 80] The excited fluorescence is collected by a microscopic objective and used for correlation analysis, from which the quantitative dynamic parameters of the sample can be obtained [81].”
Sorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956 · cited 2×
“The concept of dual-color FCCS was first proposed by Eigen and Rigler [30], and was implemented experimentally by Schwille et al. [31] In dual-color FCCS, two species of interest are labeled with two different types of spectrally distinct fluorophores, indicated with the subscript r (red) and g (green) for simplicity.”
MethodSchwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817 · cited 1×
“[31] In dual-color FCCS, two species of interest are labeled with two different types of spectrally distinct fluorophores, indicated with the subscript r (red) and g (green) for simplicity.”
Background
Cited by
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Synthesis and Characterization of MOF‐Derived Structures: Recent Advances and Future Perspectives
Payam, A. F., Khalil, S., & Chakrabarti, S. (2024) · Small · doi:10.1002/smll.202310348 · Cited by 208
Metadata
- Authors
- Yu, L., Lei, Y., Ma, Y., Liu, M., Zheng, J., Dan, D., & Gao, P.
- Venue
- Frontiers in Physics
- Publisher
- Frontiers Media SA
- Published
- 2021-04-12
- Volume
- 9
- ISSN
- 2296-424X (ISSN-L)
- OpenAlex
- W3155967852
- Cited by
- 216
- References
- 118
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comprehensive Review of Fluorescence Correlation Spectroscopy. https://app.cochat.ai/papers/10.3389/fphy.2021.644450
- The paper
- Yu, L., Lei, Y., Ma, Y., Liu, M., Zheng, J., Dan, D., & Gao, P. (2021). A Comprehensive Review of Fluorescence Correlation Spectroscopy. Frontiers in Physics. https://doi.org/10.3389/fphy.2021.644450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.