Ensuring reliability of safety-critical clinical applications of computational cardiac models
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Computational models of cardiac electrophysiology have been used for over half a century to investigate physiological mechanisms and generate hypotheses for experimental testing, and are now starting to play a role in clinical applications. There is currently a great deal of interest in using models as diagnostic or therapeutic aids, for example using patient-specific whole-heart simulations to optimize cardiac resynchronization therapy, ablation therapy, and defibrillation. However, if models are to be used in safety-critical clinical decision making, the reliability of their predictions needs to be thoroughly investigated. In engineering and the physical sciences, the field of "verification, validation and uncertainty quantification" (VVUQ) [also known as "verification and validation" (V&V)] has been developed for rigorously evaluating the credibility of computational model predictions. In this article we first discuss why it is vital that cardiac models be developed and evaluated within a VVUQ framework, and then consider cardiac models in the context of each of the stages in VVUQ. We identify some of the major difficulties which may need to be overcome for cardiac models to be used in safely-critical clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayesian calibration of computer models
Kennedy, M. C., & O'Hagan, A. (2001) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00294 · Cited by 4,222
Verification and Validation in Scientific Computing
Oberkampf, W. L., & Roy, C. J. (2010) · doi:10.1017/cbo9780511760396 · Cited by 1,556
Noble, D. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006849 · Cited by 957
Verification of cardiac tissue electrophysiology simulators using an N -version benchmark
Niederer, S. A., Kerfoot, E., Benson, A. P., Bernabeu, M. O., Bernus, O., Bradley, C., Cherry, E. M., Clayton, R., Fenton, F. H., Garny, A., et al. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0139 · Cited by 275
Cited by
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932
Self-citationApplicability Analysis of Validation Evidence for Biomedical Computational Models
Pathmanathan, P., Gray, R. A., Romero, V. J., & Morrison, T. M. (2017) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4037671 · Cited by 68
Self-citationRecent developments in using mechanistic cardiac modelling for drug safety evaluation
Davies, M. R., Wang, K., Mirams, G. R., Caruso, A., Noble, D., Walz, A., Lavé, T., Schuler, F., Singer, T., & Polonchuk, L. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.02.003 · Cited by 66
Validation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology
Pathmanathan, P., & Gray, R. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00106 · Cited by 63
“In a previous publication we advocated that engineeringmodel assessmentmethodologies of verification, validation and uncertainty quantification (VVUQ) could be used to improve credibility of models (Pathmanathan and Gray, 2013).”
MethodSelf-citation
Metadata
- Authors
- Pathmanathan, P., & Gray, R. A.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2013
- Volume
- 4
- Pages
- 358-358
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2028685719
- Cited by
- 48
- References
- 4
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.