CoChat

Mitochondrial Bioenergetics and Fiber Type Assessments in Microbiopsy vs. Bergstrom Percutaneous Sampling of Human Skeletal Muscle

Open access
Hughes, Meghan C., Ramos, Sofhia V., Turnbull, Patrick C., Nejatbakhsh, Ali, Baechler, Brittany L., Tahmasebi, Houman, Laham, Robert, Gurd, Brendon J., Quadrilatero, Joe, Kane, Daniel A., Perry, Christopher G. R. · 2015 · Frontiers in Physiology
Cited by 45

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Microbiopsies of human skeletal muscle are increasingly adopted by physiologists for a variety of experimental assays given the reduced invasiveness of this procedure compared to the classic Bergstrom percutaneous biopsy technique. However, a recent report demonstrated lower mitochondrial respiration in saponin-permeabilized muscle fiber bundles (PmFB) prepared from microbiopsies vs. Bergstrom biopsies. We hypothesized that ADP-induced contraction (rigor) of smaller length microbiopsy PmFB causes a greater reduction in maximal respiration vs. Bergstrom, such that respiration could be increased by a myosin II ATPase-inhibitor (Blebbistatin; BLEB). Eleven males and females each received a 2 mm diameter percutaneous microbiopsy and a 5 mm diameter Bergstrom percutaneous biopsy in opposite legs. Glutamate/malate (5/0.5 mM)-supported respiration in microbiopsy PmFB was lower than Bergstrom at submaximal concentrations of ADP. 5 μM BLEB reduced this impairment such that there were no differences relative to Bergstrom ± BLEB. Surprisingly, pyruvate (5 mM)-supported respiration was not different between either biopsy technique ±BLEB, whereas BLEB increased succinate-supported respiration in Bergstrom only. H2O2 emission was lower in microbiopsy PmFB compared to Bergstrom PmFB in the presence of BLEB. Microbiopsies contained fewer type I fibers (37 vs. 47%) and more type IIX fibers (20 vs. 8%) compared to Bergstrom possibly due to sampling site depth and/or longitudinal location. These findings suggest that smaller diameter percutaneous biopsies yield lower glutamate-supported mitochondrial respiratory kinetics which is increased by preventing ADP-induced rigor with myosin inhibition. Microbiopsies of human skeletal muscle can be utilized for assessing mitochondrial respiratory kinetics in PmFB when assay conditions are supplemented with BLEB, but fiber type differences with this method should be considered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fphys.2015.00360

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Hughes, M. C., Ramos, S. V., Turnbull, P. C., Nejatbakhsh, A., Baechler, B. L., Tahmasebi, H., Laham, R., Gurd, B. J., Quadrilatero, J., Kane, D. A., & Perry, C. G. R.
Venue
Frontiers in Physiology
Published
2015-12-18
Volume
6
Pages
360-360
ISSN
1664-042X (ISSN-L)
OpenAlex
W2218427693
Cited by
45
References
3
FWCI
0.51
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.