CoChat

Hamstring Architectural and Functional Adaptations Following Long vs. Short Muscle Length Eccentric Training

Open access
Guex, Kenny, Degache, Francis, Morisod, Cynthia, Sailly, Matthieu, Millet, Gregoire P. · 2016 · Frontiers in Physiology
Cited by 91

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Most common preventive eccentric-based exercises, such as Nordic hamstring do not include any hip flexion. So, the elongation stress reached is lower than during the late swing phase of sprinting. The aim of this study was to assess the evolution of hamstring architectural (fascicle length and pennation angle) and functional (concentric and eccentric optimum angles and concentric and eccentric peak torques) parameters following a 3-week eccentric resistance program performed at long (LML) vs. short muscle length (SML). Both groups performed eight sessions of 3-5 × 8 slow maximal eccentric knee extensions on an isokinetic dynamometer: the SML group at 0° and the LML group at 80° of hip flexion. Architectural parameters were measured using ultrasound imaging and functional parameters using the isokinetic dynamometer. The fascicle length increased by 4.9% (p < 0.01, medium effect size) in the SML and by 9.3% (p < 0.001, large effect size) in the LML group. The pennation angle did not change (p = 0.83) in the SML and tended to decrease by 0.7° (p = 0.09, small effect size) in the LML group. The concentric optimum angle tended to decrease by 8.8° (p = 0.09, medium effect size) in the SML and by 17.3° (p < 0.01, large effect size) in the LML group. The eccentric optimum angle did not change (p = 0.19, small effect size) in the SML and tended to decrease by 10.7° (p = 0.06, medium effect size) in the LML group. The concentric peak torque did not change in the SML (p = 0.37) and the LML (p = 0.23) groups, whereas eccentric peak torque increased by 12.9% (p < 0.01, small effect size) and 17.9% (p < 0.001, small effect size) in the SML and the LML group, respectively. No group-by-time interaction was found for any parameters. A correlation was found between the training-induced change in fascicle length and the change in concentric optimum angle (r = -0.57, p < 0.01). These results suggest that performing eccentric exercises lead to several architectural and functional adaptations. However, further investigations are required to confirm the hypothesis that performing eccentric exercises at LML may lead to greater adaptations than a similar training performed at SML.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fphys.2016.00340

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 91

Metadata

Authors
Guex, K., Degache, F., Morisod, C., Sailly, M., & Millet, G. P.
Venue
Frontiers in Physiology
Published
2016-08-03
Volume
7
Pages
340-340
ISSN
1664-042X (ISSN-L)
OpenAlex
W2488927599
Cited by
91
References
5
FWCI
9.98
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hamstring Architectural and Functional Adaptations Following Long vs. Short Muscle Length Eccentric Training. https://app.cochat.ai/papers/10.3389/fphys.2016.00340
The paper
Guex, K., Degache, F., Morisod, C., Sailly, M., & Millet, G. P. (2016). Hamstring Architectural and Functional Adaptations Following Long vs. Short Muscle Length Eccentric Training. Frontiers in Physiology. https://doi.org/10.3389/fphys.2016.00340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.