CoChat

Automatic landmark detection and mapping for 2D/3D registration with BoneNet

Nguyen, Van, Alves Pereira, Luis F., Liang, Zhihua, Mielke, Falk, Van Houtte, Jeroen, Sijbers, Jan, De Beenhouwer, Jan · 2022 · Frontiers in Veterinary Science
Cited by 15

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The 3D musculoskeletal motion of animals is of interest for various biological studies and can be derived from X-ray fluoroscopy acquisitions by means of image matching or manual landmark annotation and mapping. While the image matching method requires a robust similarity measure (intensity-based) or an expensive computation (tomographic reconstruction-based), the manual annotation method depends on the experience of operators. In this paper, we tackle these challenges by a strategic approach that consists of two building blocks: an automated 3D landmark extraction technique and a deep neural network for 2D landmarks detection. For 3D landmark extraction, we propose a technique based on the shortest voxel coordinate variance to extract the 3D landmarks from the 3D tomographic reconstruction of an object. For 2D landmark detection, we propose a customized ResNet18-based neural network, BoneNet, to automatically detect geometrical landmarks on X-ray fluoroscopy images. With a deeper network architecture in comparison to the original ResNet18 model, BoneNet can extract and propagate feature vectors for accurate 2D landmark inference. The 3D poses of the animal are then reconstructed by aligning the extracted 2D landmarks from X-ray radiographs and the corresponding 3D landmarks in a 3D object reference model. Our proposed method is validated on X-ray images, simulated from a real piglet hindlimb 3D computed tomography scan and does not require manual annotation of landmark positions. The simulation results show that BoneNet is able to accurately detect the 2D landmarks in simulated, noisy 2D X-ray images, resulting in promising rigid and articulated parameter estimations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fvets.2022.923449

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 41

  1. Schaub, 2021, Three-dimensional kinematics of the pelvis and caudal lumbar spine in German shepherd dogs, Front Vet Sci, 8, 709966, 10.3389/fvets.2021.709966 · doi:10.3389/fvets.2021.709966
  2. Nyakatura, 2010, Three-dimensional kinematic analysis of the pectoral girdle during upside-down locomotion of two-toed sloths (Choloepus didactylus, Linné 1758), Front Zool, 7, 21, 10.1186/1742-9994-7-21 · doi:10.1186/1742-9994-7-21
  3. Fischer, 2018, Three-dimensional kinematics of canine hind limbs: in vivo, biplanar, high-frequency fluoroscopic analysis of four breeds during walking and trotting, Sci Rep, 8, 16982, 10.1038/s41598-018-34310-0 · doi:10.1038/s41598-018-34310-0
  4. Gatesy, 2010, Scientific rotoscoping: a morphology-based method of 3-D motion analysis and visualization, J Exp Zool A Ecol Genet Physiol, 313, 244, 10.1002/jez.588 · DOI · Paper page
  5. Maintz, 1996, An overview of medical image registration methods
  6. Akhbari, 2019, Accuracy of biplane videoradiography for quantifying dynamic wrist kinematics, J Biomech, 92, 120, 10.1016/j.jbiomech.2019.05.040 · doi:10.1016/j.jbiomech.2019.05.040
  7. Zvonarev, 2013, 2D/3D registration algorithm for lung brachytherapy, Med Phys, 40, 021913, 10.1118/1.4788663 · DOI
  8. Khamene, 2006, Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy, Med Image Anal, 10, 96, 10.1016/j.media.2005.06.002 · DOI
  9. Munbodh, 2009, 2D-3D registration for prostate radiation therapy based on a statistical model of transmission images, Med Phys, 36, 4555, 10.1118/1.3213531 · DOI · Paper page
  10. Staub, 2013, A digitally reconstructed radiograph algorithm calculated from first principles, Med Phys, 40, 011902, 10.1118/1.4769413 · DOI
  11. Baka, 2013, Statistical coronary motion models for 2D+t/3D registration of X-ray coronary angiography and CTA, Med Image Anal, 17, 698, 10.1016/j.media.2013.03.003 · DOI
  12. Ito, 2015, Direct assessment of 3D foot bone kinematics using biplanar X-ray fluoroscopy and an automatic model registration method, J Foot Ankle Res, 8, 21, 10.1186/s13047-015-0079-4 · DOI
  13. Haase, 2013, 2D and 3D analysis of animal locomotion from biplanar X-ray videos using augmented active appearance models, EURASIP J Image Video Process, 2013, 45, 10.1186/1687-5281-2013-45 · DOI
  14. Maharaj, 2020, The reliability of foot and ankle bone and joint kinematics measured with biplanar videoradiography and manual scientific rotoscoping, Front Bioeng Biotechnol, 8, 106, 10.3389/fbioe.2020.00106 · doi:10.3389/fbioe.2020.00106
  15. Rosskopf, 2019, 3D hindfoot alignment measurements based on low-dose biplanar radiographs: a clinical feasibility study, Skelet Radiol, 48, 707, 10.1007/s00256-018-3089-z · doi:10.1007/s00256-018-3089-z
  16. Cai, 2021, Adaptive weighting landmark-based group-wise registration on lung DCE-MRI images, IEEE Trans Med Imaging, 40, 673, 10.1109/TMI.2020.3035292 · DOI
  17. Nath, 2019, Using DeepLabCut for 3D markerless pose estimation across species and behaviors, Nat Protoc, 14, 2152, 10.1038/s41596-019-0176-0 · DOI · Paper page
  18. Laurence-Chasen, 2020, Integrating XMALab and DeepLabCut for high-throughput XROMM, 10.1242/jeb.226720 · DOI
  19. Peng, 2019, PVNet: pixel-wise voting network for 6DoF pose estimation, 10.1109/CVPR.2019.00469 · DOI · Paper page
  20. Rister, 2017, Volumetric image registration from invariant keypoints, IEEE Trans Image Process, 26, 4900, 10.1109/TIP.2017.2722689 · DOI
  21. Voglis, 2004, A rectangular trust region dogleg approach for unconstrained and bound constrained nonlinear optimization
  22. H Press, 2007, Numerical Recipes the Art of Scientific Computing
  23. Sibille, 2002, Interactive simulation of the human hand, 7
  24. Oberweger, 2018, Making deep heatmaps robust to partial occlusions for 3d object pose estimation, 119
  25. Tekin, 2018, Real-time seamless single shot 6d object pose prediction, 292
  26. Van Aarle, 2015, The ASTRA Toolbox: a platform for advanced algorithm development in electron tomography, Ultramicroscopy, 157, 35, 10.1016/j.ultramic.2015.05.002 · DOI · Paper page
  27. Van Aarle, 2016, Fast and flexible X-ray tomography using the ASTRA toolbox, Opt Exp, 24, 25129, 10.1364/OE.24.025129 · DOI · Paper page
  28. De Samber, 2021, FleXCT: a Flexible X-ray CT scanner with 10 degrees of freedom, Opt Exp, 29, 3438, 10.1364/OE.409982 · DOI
  29. 2018, MATLAB version 9.5 (R2018b)
  30. Arsigny, 2005, Polyrigid and polyaffine transformations: a novel geometrical tool to deal with non-rigid deformations - application to the registration of histological slices, Med Image Anal, 9, 507, 10.1016/j.media.2005.04.001 · DOI
  31. McKinley, 1998, Cubic spline interpolation, Coll Redwoods, 45, 1049
  32. Kingma, 2015, Adam: a method for stochastic optimization
  33. Murphy, 2012, Machine Learning: a Probabilistic Perspective
  34. da Costa, 2016, An empirical study on the effects of different types of noise in image classification tasks
  35. Liu, 2021, The impact of noise level mismatch between training and testing images for deep learning-based PET denoising
  36. Ziyadinov, 2022, Noise immunity and robustness study of image recognition using a convolutional neural network, Sensors, 22, 1241, 10.3390/s22031241 · DOI
  37. Deep Learning. MIT Press GoodfellowI BengioY CourvilleA 2016
  38. Neelakantan, 2015, Adding gradient noise improves learning for very deep networks
  39. Nazaré, 2018, Deep convolutional neural networks and noisy images., 416, 10.1007/978-3-319-75193-1_50 · DOI
  40. Andreozzi, 2021, Toward a priori noise characterization for real-time edge-aware denoising in fluoroscopic devices, BioMed Eng OnLine, 20, 36, 10.1186/s12938-021-00874-8 · DOI
  41. Sanctorum, 2019, Methods for characterization and optimisation of measuring performance of stereoscopic X-ray systems with image intensifiers, Measure Sci Technol, 30, 105701, 10.1088/1361-6501/ab23e7 · doi:10.1088/1361-6501/ab23e7

Cited by

Metadata

Authors
Nguyen, V., Alves Pereira, L. F., Liang, Z., Mielke, F., Van Houtte, J., Sijbers, J., & De Beenhouwer, J.
Venue
Frontiers in Veterinary Science
Published
2022-08-18
Volume
9
ISSN
2297-1769
Cited by
15
References
5

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.