Design challenges of implantable pressure monitoring system
Open accessThe DOI matches its Crossref record.
Abstract
Pressure in various organs and body parts, such as blood vessels, heart, brain, eyes, bladder and GI tracts, is an important indication of health. Long term, continuous pressure monitoring is critically needed for a number of applications. When combined with existing neuro-prosthetics devices, they may provide better solutions to many neural disorders. First efforts toward a long-term implantable pressure monitoring system were initiated more than 40 years ago. However, a reliable, safe and implantable pressure sensor for long-term applications is not yet commercially available. This paper attempts to reveal the design challenges associated with the development of a long-term implantable pressure sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-speed recording of neural spikes in awake mice and flies with a fluorescent voltage sensor
Gong, Y., Huang, C., Li, J. Z., Grewe, B. F., Zhang, Y., Eismann, S., & Schnitzer, M. J. (2015) · Science · doi:10.1126/science.aab0810 · Cited by 462
Shin, J., Yan, Y., Bai, W., Xue, Y., Gamble, P., Tian, L., Kandela, I., Haney, C. R., Spees, W., Lee, Y., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0300-4 · Cited by 263
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
“, oxygen) can cause oxidation of interconnect metals such as solders, which in turn can lead to attachment failure [18].”
BackgroundPolymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 163
Tao, C., Yang, H., Zhu, Z., Ni, S., Jiang, J., Jiang, W., Zhou, Z., Sun, L., Liu, K., Tao, T. H., et al. (2024) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/2809/1/012001
Metadata
- Authors
- Jiang, G.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 4
- Pages
- 29-29
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2041486708
- Cited by
- 49
- References
- 0
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design challenges of implantable pressure monitoring system. https://app.cochat.ai/papers/10.3389/neuro.20.002.2010
- The paper
- Jiang, G. (2010). Design challenges of implantable pressure monitoring system. Frontiers in Neuroscience. https://doi.org/10.3389/neuro.20.002.2010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.