Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; none of the 20 sources its claims cite is checked for support yet.
Abstract
This study presents a novel approach for designing bipolar MVDC cables for lunar subsurface power transmission.
Overview
CoChat Summary
TL;DR
This study designs and analyzes coaxial bipolar MVDC cables for lunar subsurface power transmission using a COMSOL coupled electrothermal model, with Kapton® MT+ insulation and aluminum or copper conductors at ±5/±10 kV and 200 kW/1 MW/2 MW. It finds aluminum generally lowers weight at medium/high power, higher voltage ±10 kV improves design efficiency, and the designed cable is lighter and smaller than a Southwire 5 kV NL-EPR benchmark.
Key findings
- Aluminum conductors consistently show lower weight per unit length than copper at medium and high power. For 200 kW at ±10 kV, Al weighs 0.0608 kg/m, about 12% less than Cu; at 1 MW, Al is 0.3567 kg/m, about 39.41% lower than Cu; at 2 MW, Al is 1.0092 kg/m, about 82% lower than Cu’s 1.8383 kg/m.
- Higher voltage reduces weight: switching Al from ±10 kV to ±5 kV raises weight to 0.0879 kg/m at 200 kW (reported as ~44.57% increase), 0.9602 kg/m at 1 MW (~169% higher), and 2.8991 kg/m at 2 MW (~187% higher).
- Copper needs smaller cross-sectional area, while aluminum often gives lower combined weight-area parameter J. For 200 kW, Cu at ±10 kV has the smallest area, 22.602 mm² (~13.6% smaller than Al) and the lowest J, 1.5617 g.mm (~1.81% lower than Al). For 1 MW and 2 MW, Al at ±10 kV has the lowest J, 50.266 g.mm (~12.5% lower than Cu) and 392.69 g·mm (~17.6% lower than Cu), respectively.
- For 2 MW at ±5 kV, the designed coaxial cable weighs 5.7802 kg/m versus 7.7157 kg/m for the NL-EPR cable (~25% lower) and has 693.81 mm² area versus 1748.6 mm² (~60% lower). Maximum electric field is 2.24 × 10⁷ V/m, meeting the E_max < 0.2E_bd criterion, and cable surface temperature stabilizes around 260 °C.
Methods
- A coupled electrothermal model was built in COMSOL Multiphysics 6.1 using heat transfer, electric current, and magnetic field modules. The cable is placed 30 cm below the lunar surface; only conductive heat transfer is modeled. Surface temperature is held at 110.85 °C for 327.6 h and −171.1 °C for 327.6 h, with a 2000 h simulation; soil thermal conductivity is constant at 1.0 × 10⁻⁴ W/(cm·K). Mesh used 19,866 vertices and 39,474 triangular elements.
- The design is a coaxial bipolar MVDC cable using Kapton® MT+ insulation, a Teflon® PFA jacket, and a copper EMI screen, with Al or Cu core conductors. Kapton® MT+ is selected for its −269 to 400 °C range, 0.75 W/m·K thermal conductivity, and dielectric constant 4.2, compared with XLPE (0.46 W/m·K, 2.5) and NL-EPR (0.3 W/m·K, 2.5).
- Optimization determines insulation number, type, and thickness to minimize weight and volume while meeting electrical and thermal limits: E_max < 0.2E_bd and T_max < T_limit. The study covers 12 cases: 200 kW, 1 MW, and 2 MW at ±5 kV and ±10 kV, with Al or Cu. Results compare weight per unit length, cross-sectional area, and J = m·A, and benchmark against a Southwire 5 kV NL-EPR cable for 2 MW.
Limitations
- Stated: the simulation accounts only for conductive heat transfer, ignores pressure fluctuations, assumes micrometeoroid bombardment is less impactful at 30 cm depth, and assumes 30 cm depth protects against solar wind and SEPs while noting GCRs could still impact the cable. The specific impact of charged particles remains uncertain, and the insulation design does not address deep dielectric charging.
- Stated: cable lifespan was not directly assessed; the simulation ran for 2000 h, and without experimental testing the precise lifespan remains uncertain, requiring ongoing monitoring and further assessment.
- Evident from the text: no experimental validation is reported, and Kapton® MT+ and Teflon® PFA conductivities were approximated as polyimide (PI) and ethylene-tetrafluoroethylene (ETFE), respectively, due to lack of specific data. Some numerical statements in the provided text also appear duplicated or inconsistently worded, such as the 44.57% comparison.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 2 Not valid · 17 Not checked · 48 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For 200 kW power transmission, the aluminum conductor at ±10 kV exhibits the lowest weight per unit length, measuring 0.0608 kg/m.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This represents a significant increase of approximately 44.57% compared to the ±5 kV voltage level.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Additionally, elevated voltage levels (±10 kV) enhance cable design and power transfer efficiency.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For a 2 MW power transmission, again, aluminum conductors exhibit the lowest weight per unit length at ±10 kV voltage, measuring 1.0092 kg/m.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Core conductor diameter and insulation thickness were determined using COMSOL simulations, ensuring that the cable reaches the maximum allowable temperature of 260 • C for the specified power level while operating at a fixed current.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 3.2. Proposed Insulation Designs
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
29 more claims
Create a free account to see all 67 claims and every source verdict.
- It may state two separate claims as one. 25
- The quote only partly states this claim. 2
- Probably not a substantial claim. 8
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
“At a ±5 kV voltage level, the copper conductor still exhibits the lowest crosssectional area of 22.934 mm 2”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 5. Conclusions
“| 200 | Cu | 1.32 | 0.50 | 0.4283 | 0.225 | 5.40 |”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
“When the voltage is reduced from ±10 kV to ±5 kV, using the same core conductor material (aluminum), the weight of the conductor increases to 0.0879 kg/m.This represents a significant increase of approximately 44.57% compared to the ±5 kV voltage level.”
§ Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission > 4. Simulation Results
“For 200 kW power transmission, the aluminum conductor at ±10 kV exhibits the lowest weight per unit length, measuring 0.0608 kg/m.”
Citations
Cites
(1973) · NASA Technical Reports Server (NASA) · Cited by 98
(1972) · NASA Technical Reports Server (NASA) · Cited by 60
Optimal Bipolar MVDC Power Cable Designs for Future Wide-Body All Electric Aircraft
Saha, A., Azizi, A., & Ghassemi, M. (2024) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2024.3355033 · Cited by 46
Self-citationHigh Temperature Insulation Materials for DC Cable Insulation — Part I: Space Charge and Conduction
Baferani, M. A., Li, C., Shahsavarian, T., et al. (2021) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2020.009167 · Cited by 42 · cited 1×
“The electrical conductivity of PI and ETFE has been determined through curve fitting of the data from [25].”
MethodKhan, Z. (2006) · AIP Conference Proceedings · doi:10.1063/1.2169289 · Cited by 36 · cited 1×
“These systems are crucial for sustaining a long-term presence on the moon, supporting human activities, enabling research efforts, and powering vital technological activities [1–3].”
BackgroundSaha, A., & Ghassemi, M. (2024) · IEEE Access · doi:10.1109/access.2024.3368437 · Cited by 34
Self-citationVacuum Measurements on the Lunar Surface
Johnson, F. S., Carroll, J. M., & Evans, D. E. (1972) · Journal of Vacuum Science and Technology · doi:10.1116/1.1316652 · Cited by 26 · cited 1×
“The atmospheric pressure on the moon varies from around 10 − 8 torr during the day to 10 − 12 torr at night [9–11].”
BackgroundMoon: Electrical Properties of the Uppermost Layers
Strangway, D. W. (1969) · Science · doi:10.1126/science.165.3897.1012 · Cited by 23
Kirkici, H., Rose, M. F., & Chaloupka, T. (1996) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/94.485523 · Cited by 23 · cited 1×
“Experimental studies in [21,22] have demonstrated that simulated lunar soil under a pressure of 10 − 7 Pa serves as a reliable insulator.”
BackgroundCalculation of the cyclic and emergency current rating of cables
(2015) · doi:10.3403/bsiec60853 · Cited by 21
Research works printed but not linked: 5
- 5. IEC 60287-1-1:2006; Electric Cables-Calculation of the Current Rating-Part 1-1: Current Rating Equations (100% Load Factor) and Calculation of Losses-General. IEC: Geneva, Switzerland, 2006; pp. 1-136.
- 7. IEC 60986:2000; Short-Circuit Temperature Limits of Electric Cables with Rated Voltages from 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV). IEC: Geneva, Switzerland, 2000; pp. 1-19.
- 8. IEC TR 62095:2003; Electric Cables-Calculations for Current Ratings-Finite Element Method. IEC: Geneva, Switzerland, 2003; pp. 1-69.
- 9. Smith, R.E.; West, G.S. Space and Planetary Environment Criteria Guidelines for Use in Space Vehicle Development. Volume 1: 1982 Revision; 1983; Volume 83, p. 18816. Available online: https://ntrs.nasa.gov/api/citations/19830019790/downloads/1983001979 0.pdf (accessed on 13 April 2024).
- 22. Heiken, G.; Vaniman, D.; French, B.M. Lunar Sourcebook; Cambridge University Press: New York, NY USA, 1991.
Cited by
State-of-the-Art DC-DC Converters for Satellite Applications: A Comprehensive Review
Ravindran, R., & Massoud, A. M. (2025) · Aerospace · doi:10.3390/aerospace12020097 · Cited by 36
Designing High-Power Density MVDC Bipolar Power Cables for Power Transmission on the Moon
Saha, A., & Ghassemi, M. (2024) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2024.3513959 · Cited by 3
“We designed the cable only for the below-surface scenario, using Kapton MT + as the insulating material [21].”
Self-citationSedahmed, M. S. M., & Hassaan, M. M. E. (2025) · Fire · doi:10.3390/fire8050204 · Cited by 1
“The mesh plays a crucial role in the simulation process, possibly necessary for achieving the highest quality results in the shortest time [38–40].”
Ghassemi, M. (2024) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2024.10721383
Self-citationLunar surface energy infrastructure: from in-situ resource utilization to deep space exploration
Gao, Y., Shi, Q., Ding, L., Zhou, Y., Zhou, C., & Han, W. (2026) · npj Space Exploration · doi:10.1038/s44453-026-00053-w · Cited by 1
“Thesemethodscansupportpowertransferupto 1MWandavoidthestructuralcomplexityoftowers 105,106 .”
Lunar electrical grid development concepts
Williams, H. (2026) · Space and Planetary Resources · doi:10.1007/s44461-026-00016-9
“Wire material is another open question; copper was the first material used in long distance transmission, modern transmission cable is generally made of aluminum conductor steel reinforced cable, and multi-material solutions have been explored (Thrash 2014) (Saha, 2024).”
Metadata
- Authors
- Saha, A., & Ghassemi, M.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Ghassemi, Mona
- Venue
- Aerospace
- Publisher
- MDPI AG
- Published
- 2024-08-20
- Volume
- 11
- Issue
- 8
- Pages
- 685
- ISSN
- 2226-4310 (ISSN-L)
- OpenAlex
- W4401976955
- Semantic Scholar
- 496a68d45efa50d75f598a8d3960fb4364d664ad
- Cited by
- 8
- References
- 22
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 3
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Aerospace (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Thermal Analysis in Power Transmission
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Keywords
- aluminum conductors, copper conductors, lunar temperature, ionizing radiation, micrometeoroid impacts, power transfer efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.