Deep Learning for Raman Spectroscopy: A Review
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy (RS) is a spectroscopic method which indirectly measures the vibrational states within samples. This information on vibrational states can be utilized as spectroscopic fingerprints of the sample, which, subsequently, can be used in a wide range of application scenarios to determine the chemical composition of the sample without altering it, or to predict a sample property, such as the disease state of patients. These two examples are only a small portion of the application scenarios, which range from biomedical diagnostics to material science questions. However, the Raman signal is weak and due to the label-free character of RS, the Raman data is untargeted. Therefore, the analysis of Raman spectra is challenging and machine learning based chemometric models are needed. As a subset of representation learning algorithms, deep learning (DL) has had great success in data science for the analysis of Raman spectra and photonic data in general. In this review, recent developments of DL algorithms for Raman spectroscopy and the current challenges in the application of these algorithms will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Backpropagation Applied to Handwritten Zip Code Recognition
LeCun, Y., Boser, B., Denker, J. S., Henderson, D., Howard, R. E., Hubbard, W., & Jackel, L. D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.541 · Cited by 11,891
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172 · cited 1×
“Therefore, enhancement techniques, such as coherent anti-Stokes Raman spectroscopy (CARS) [3] and surface-enhanced Raman spectroscopy (SERS) [4], were invented.”
Mater, A. C., & Coote, M. L. (2019) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.9b00266 · Cited by 565 · cited 1×
“With the rapid development of computer science, deep learning has changed numerous traditional research fields, including photonics [20], chemistry [21], and biology [22].”
Guo, S., Popp, J., & Bocklitz, T. (2021) · Nature Protocols · doi:10.1038/s41596-021-00620-3 · Cited by 361 · cited 2×
“…and implementation of the pre-processing (sequence) becomes a heavy burden [30]. normalisation as well as dimension reduction are always needed [2,29]. the computational complexity of the above-mentioned pre-processing sequence is high simply no universal pre-processing technique exists, the…”
Self-citationThrift, W. J., & Ragan, R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03599 · Cited by 89 · cited 4×
“For example, Thrift and Ragan tried a CNN-based single molecule SERS quantification method that transferred the knowledge from Rhodamine 800 (R800) domain to methylene blue (MB) domain.”
InfluentialPan, L., Pipitsunthonsan, P., Daengngam, C., Channumsin, S., Sreesawet, S., & Chongcheawchamnan, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3059849 · Cited by 29 · cited 1×
“Besides, Pan and his colleagues even increased the Raman data dimension from 1D to 2D by wavelet transform before classification [49,50].”
Cited by
A review on spectral data preprocessing techniques for machine learning and quantitative analysis
Yan, C. (2025) · iScience · doi:10.1016/j.isci.2025.112759 · Cited by 193
Benavides-Hernández, J., & Dumeignil, F. (2024) · ACS Catalysis · doi:10.1021/acscatal.3c06293 · Cited by 190
Hyperspectral unmixing for Raman spectroscopy via physics-constrained autoencoders
Georgiev, D., Fernández-Galiana, Á., Vilms Pedersen, S., Papadopoulos, G., Xie, R., Stevens, M. M., & Barahona, M. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2407439121 · Cited by 50
RamanFormer: A Transformer-Based Quantification Approach for Raman Mixture Components
Koyun, O. C., Keser, R. K., Şahin, S. O., Bulut, D., Yorulmaz, M., Yücesoy, V., & Töreyin, B. U. (2024) · ACS Omega · doi:10.1021/acsomega.3c09247 · Cited by 32
Metadata
- Authors
- Luo, R., Popp, J., & Bocklitz, T.
- Venue
- Analytica
- Publisher
- MDPI AG
- Published
- 2022-07-19
- Volume
- 3
- Issue
- 3
- Pages
- 287-301
- ISSN
- 2673-4532 (ISSN-L)
- OpenAlex
- W4285796506
- Cited by
- 244
- References
- 9
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.