Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Gradually Applying Weakly Supervised and Active Learning for Mass Detection in Breast Ultrasound Images

Open access
Yun, JooYeol, Oh, JungWoo, Yun, IlDong · 2020 · Applied Sciences

Abstract

We propose a method for effectively utilizing weakly annotated image data in an object detection tasks of breast ultrasound images. Given the problem setting where a small, strongly annotated dataset and a large, weakly annotated dataset with no bounding box information are available, training an object detection model becomes a non-trivial problem. We suggest a controlled weight for handling the effect of weakly annotated images in a two stage object detection model. We also present a subsequent active learning scheme for safely assigning weakly annotated images a strong annotation using the trained model. Experimental results showed a 24% point increase in correct localization (CorLoc) measure, which is the ratio of correctly localized and classified images, by assigning the properly controlled weight. Performing active learning after a model is trained showed an additional increase in CorLoc. We tested the proposed method on the Stanford Dog datasets to assure that it can be applied to general cases, where strong annotations are insufficient to obtain resembling results. The presented method showed that higher performance is achievable with lesser annotation effort.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app10134519

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Research works printed but not linked: 1

  1. Ragesh, N., Anil, A., and Rajesh, R. (2011, January 12). Digital image denoising in medical ultrasound images: A survey. Proceedings of the Icgst Aiml-11 Conference, Dubai, UAE.

Cited by

See all 7

Metadata

Authors
Yun, J., Oh, J., & Yun, I.
Affiliations
  • Korea University (KR)
  • Department of Computer and Electronic Systems Engineering, Hankuk University of Foreign Studies, Yongin 17035, Korea
Venue
Applied Sciences
Publisher
MDPI AG
Published
2020-06-29
Volume
10
Issue
13
Pages
4519
ISSN
2076-3417 (ISSN-L)
OpenAlex
W3038634042
Cited by
7
References
15
Citations by year
2025: 2 · 2024: 3 · 2023: 2
FWCI
0.20
Type
journal article
Language
en
Open access
Locations
  • Applied Sciences (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University)
Funders
Minestry of Education, Science, Technology (2019R1A2C1085113)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
  • Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
Keywords
breast ultrasound, mass detection, weakly supervised learning, active learning (machine learning), object detection, two-stage object detection, annotation cost reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gradually Applying Weakly Supervised and Active Learning for Mass Detection in Breast Ultrasound Images. https://app.cochat.ai/papers/10.3390/app10134519
The paper
Yun, J., Oh, J., & Yun, I. (2020). Gradually Applying Weakly Supervised and Active Learning for Mass Detection in Breast Ultrasound Images. Applied Sciences. https://doi.org/10.3390/app10134519

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.