Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.

Performance of Commercial Li-Ion Cells for Future NASA Missions and Aerospace Applications

Open access
Krause, F. C., Ruiz, J. P., Jones, S. C., Brandon, E. J., Darcy, E. C., Iannello, C. J., Bugga, R. V. · 2021 · Journal of The Electrochemical Society

Abstract

Li-ion batteries are being widely used in planetary missions, based on their impressive performance characteristics, including high specific energy, long life, and the ability to operate over a wide temperature range. Custom large-format Li-ion cells were used in the early planetary missions, e.g., Mars Rovers, Mars Landers, and Mars and Jupiter Orbiters. At the same time, several other robotic missions have utilized and are planning to utilize commercial 18650 lithium-ion cells, e.g., Mars Express, Lunar Reconnaissance Orbiter, Europa Clipper, as well as human-rated astronaut Extra-Vehicular Activities. Interest in commercial 18650 lithium-ion cells for NASA missions has increased in recent years due to distinct advantages over custom large-format cells, including higher specific energy and energy density, enhanced safety and reliability, modularity and redundancy in the battery design, and simpler charge methodology. Multiple commercial 18650 cells are available which can provide a specific energy of ∼250 Wh∙kg−1(20%–50% over custom cells) and a power density of ∼2 kW∙kg−1. Selected cell types with different chemistries and from multiple high-quality manufacturers, including the MJ1, M36, HG2 models from LG Chem; the 35E, 36 G and 30Q models from Samsung; the BJ and GA models from Sanyo/Panasonic; and the VC7 from Sony/Murata, were evaluated for their applicability in space applications. The performance tests included cycle life at different temperatures and depths of discharge, and high-power characterization at different temperatures; to supplement typical electrical measurements of voltage, capacity, and energy, Electrochemical Impedance Spectroscopy (EIS) was used to characterize the health of some cells on an ongoing basis. In addition, destructive physical analysis was carried out on these cells to analyze their electrode materials and correlate them with their performance characteristics. The demonstrated performance of several cells indicated their viability for further extensive space-qualification prior to their implementation in space missions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1945-7111/abf05f

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Research works printed but not linked: 3

  1. Nagaura, 1990, Prog. Batteries Sol. Cells, 9, 20
  2. Ohzuku, 2001, Chem. Lett., 5, 874
  3. Smart, 1999, Electrolytes for low‐temperature lithium batteries based on ternary mixtures of aliphatic carbonates, J. Electrochem. Soc., 146, 486, 10.1149/1.1391633 · DOI · Paper page

Cited by

See all 98

Metadata

Authors
Krause, F. C., Ruiz, J. P., Jones, S. C., Brandon, E. J., Darcy, E. C., Iannello, C. J., & Bugga, R. V.
Affiliations
  • California Institute of Technology (US)
  • Johnson Space Center (US)
  • Kennedy Space Center (US)
Corresponding author
Bugga, R. V.
Venue
Journal of The Electrochemical Society
Published
2021-04-01
Volume
168
Issue
4
Pages
040504
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W3139242209
Cited by
90
References
41
Citations by year
2026: 17 · 2025: 25 · 2024: 16 · 2023: 18 · 2022: 12 · 2021: 2
FWCI
3.90
Type
journal article
Language
en
Open access
Licence
Locations
Journal of The Electrochemical Society (publishedVersion, cc-by-nc-nd)
Funders
  • National Aeronautics and Space Administration (80NM0018D0004)
  • University of California, Santa Cruz
  • California Institute of Technology (80 NM0018D0004)
  • Jet Propulsion Laboratory (80NM0018D0004)
  • NASA Engineering and Safety Center
Topics
  • Physical Sciences › Engineering › Automotive Engineering › Battery Modeling and Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Battery Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Battery Materials and Technologies
Keywords
lithium-ion cells, 18650 cells, space power systems, planetary missions, cycle life, depth of discharge, temperature effects, electrochemical impedance spectroscopy, destructive physical analysis, electrode materials, battery health monitoring, NASA missions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Commercial Li-Ion Cells for Future NASA Missions and Aerospace Applications. https://app.cochat.ai/papers/10.1149/1945-7111/abf05f
The paper
Krause, F. C., Ruiz, J. P., Jones, S. C., Brandon, E. J., Darcy, E. C., Iannello, C. J., & Bugga, R. V. (2021). Performance of Commercial Li-Ion Cells for Future NASA Missions and Aerospace Applications. Journal of The Electrochemical Society. https://doi.org/10.1149/1945-7111/abf05f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.