The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Critical Design Considerations for Longer-Term Wear and Comfort of On-Body Medical Devices
Open accessAbstract
The commercialization of a growing number of wearable devices has been enabled within recent years due to the availability of miniaturized sensor modalities, the development of new materials, and the scalability of flexible electronics. With the increase in resource shortages within healthcare, there is a demand to translate wearable devices from the commercial consumer stand-point to the medical field. Clinical-grade signal quality, wearability, and comfort all need to be tailored to a wearable design. Wear and comfort for user compliance and durability for longer-term use are commonly overlooked. In this study, the relationship of on-body location and material layer composition is investigated. Five non-woven medical tapes noted for longer wear time are tested over a 7-day timeframe. The impact of material properties, such as elasticity, isotropy, and hysteresis, as well as the moisture vapor transmission rate (MVTR) and adhesive thickness, are evaluated in relation to skin properties on the lower torso of 30, high-activity-level volunteers. User perception was quantified via Likert-scale questionnaires and images were obtained for the material–skin interaction. The results indicate that critical characteristics, such as MVTR and elasticity, noted for positive skin interaction in commercial products, may not translate to improved user perception and durability over time. Future work will assess new design options to manipulate material properties for improved wear and comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures











Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, flexible sensor materials often face the contradiction between mechanical performance degradation and signal stability reduction, especially under long-term wearing or complex dynamic environments 177,178 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [177]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
User acceptance of wearable devices: An extended perspective of perceived value
Yang, H., Yu, J., Zo, H., & Choi, M. (2016) · Telematics and Informatics · doi:10.1016/j.tele.2015.08.007 · Cited by 631
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Mechanical Behaviour of Skin: A Review
A, K., & A, L. (2016) · Journal of Material Science & Engineering · doi:10.4172/2169-0022.1000254 · Cited by 260
Multifunctional Smart Skin Adhesive Patches for Advanced Health Care
Hwang, I., Kim, H. N., Seong, M., Lee, S., Kang, M., Yi, H., Bae, W. G., Kwak, M. K., & Jeong, H. E. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800275 · Cited by 227
The Rise of Wearable Devices during the COVID-19 Pandemic: A Systematic Review
Channa, A., Popescu, N., Skibinska, J., & Burget, R. (2021) · Sensors · doi:10.3390/s21175787 · Cited by 209
Recent developments in sensors for wearable device applications
Cheng, Y., Wang, K., Xu, H., Li, T., Jin, Q., & Cui, D. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03602-2 · Cited by 174
Recent advances in smart wearable sensors for continuous human health monitoring
Kulkarni, M. B., Rajagopal, S., Prieto-Simón, B., & Pogue, B. W. (2024) · Talanta · doi:10.1016/j.talanta.2024.125817 · Cited by 173
Cited by
Bioinspired flexible photonic sensing chips for wearable multiparameter monitoring
Lin, Y., Huang, Y., Wang, T., Cai, S., Wu, Y., Li, L., Yang, Z., & Chen, J. (2025) · FlexMat. · doi:10.1002/flm2.70007 · Cited by 29
Exploring the Design for Wearability of Wearable Devices: A Scoping Review
Seo, Y. W., Marca, V. L., Tandon, A. A., Chiao, J. ‐., & Drummond, C. K. (2024) · Computers · doi:10.3390/computers13120326 · Cited by 26
“Issues related to design considerations for longer-term wear need to be considered in the device design process [32,33].”
Xu, D., Yang, Y., Numata, K., & Pang, B. (2026) · Nano-Micro Letters · doi:10.1007/s40820-025-02059-7 · Cited by 19
“…including PET, polyethylene naphthalate (PEN), polyimide (PI), and elastomeric ther-moplastic polyurethane (TPU)—even commercial products with high moisture vapor transmission rates and well-matched elasticity do not necessarily achieve improved user perception or long-term durability [75].”
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Stroke Rehabilitation, Novel Technology and the Internet of Medical Things
Costa, A., Schmalzried, E., Tong, J., Khanyan, B., Wang, W., Jin, Z., & Bergese, S. D. (2026) · Brain Sciences · doi:10.3390/brainsci16020124 · Cited by 8
“Physical tolerability is also a limiting factor; adhesive electrodes and prolonged skin contact can cause irritation, discomfort, and early discontinuation—issues that may be amplified in older adults and in patients with sensory changes [25].”
Metadata
- Authors
- Stuart, S., de Kok, M., O’Searcoid, B., Morrisroe, H., Serban, I. B., Jagers, F., Dulos, R., Houben, S., van de Peppel, L., & van den Brand, J.
- Affiliations
- Holst Centre (Netherlands) (NL)
- TNO, Holst Centre, High Tech Campus 31, 5656AE Eindhoven, The Netherlands
- Industrial Design and Artificial Intelligence Systems Institute, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands
- Netherlands Organisation for Applied Scientific Research (NL)
- Eindhoven University of Technology (NL)
- Corresponding author
- Stuart, Shavini
- Venue
- Bioengineering
- Publisher
- MDPI AG
- Published
- 2024-10-24
- Volume
- 11
- Issue
- 11
- Pages
- 1058
- ISSN
- 2306-5354 (ISSN-L)
- PMC
- PMC11591458
- OpenAlex
- W4403735054
- Cited by
- 14
- References
- 27
- Citations by year
- 2026: 8 · 2025: 5 · 2024: 1
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Bioengineering (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- TNO Repository (submittedVersion)
- TU/e Research Portal (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ITEA INNO4HEALTH (19008)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- wearable medical devices, user comfort, adhesive durability, water vapor transmission rate, hysteresis, user compliance, flexible electronics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.