The DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope
Open accessAbstract
The electrochemical biosensors are a class of biosensors which convert biological information such as analyte concentration that is a biological recognition element (biochemical receptor) into current or voltage. Electrochemical biosensors depict propitious diagnostic technology which can detect biomarkers in body fluids such as sweat, blood, feces, or urine. Combinations of suitable immobilization techniques with effective transducers give rise to an efficient biosensor. They have been employed in the food industry, medical sciences, defense, studying plant biology, etc. While sensing complex structures and entities, a large data is obtained, and it becomes difficult to manually interpret all the data. Machine learning helps in interpreting large sensing data. In the case of biosensors, the presence of impurity affects the performance of the sensor and machine learning helps in removing signals obtained from the contaminants to obtain a high sensitivity. In this review, we discuss different types of biosensors along with their applications and the benefits of machine learning. This is followed by a discussion on the challenges, missing gaps in the knowledge, and solutions in the field of electrochemical biosensors. This review aims to serve as a valuable resource for scientists and engineers entering the interdisciplinary field of electrochemical biosensors. Furthermore, this review provides insight into the type of electrochemical biosensors, their applications, the importance of machine learning (ML) in biosensing, and challenges and future outlook.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761
Support Vector Method for Function Approximation, Regression Estimation, and Signal Processing
Vapnik, V. N., Golowich, S. E., & Smola, A. J. (1997) · Cited by 2,757
Brain Tumor Segmentation Using Convolutional Neural Networks in MRI Images
Pereira, S., Pinto, A., Alves, V., & Silva, C. A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2538465 · Cited by 2,735
Machine Learning Algorithms - A Review
Mahesh, B. (2020) · International Journal of Science and Research (IJSR) · doi:10.21275/art20203995 · Cited by 2,510
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., & Adeli, H. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.09.017 · Cited by 1,647
Setio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2536809 · Cited by 1,258
An overview of foodborne pathogen detection: In the perspective of biosensors
Velusamy, V., Arshak, K., Korostynska, O., Oliwa, K., & Adley, C. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.12.004 · Cited by 1,185
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
Hollon, T. C., Pandian, B., Adapa, A. R., Urias, E., Save, A. V., Khalsa, S. S. S., Eichberg, D. G., D’Amico, R. S., Farooq, Z. U., Lewis, S., et al. (2020) · Nature Medicine · doi:10.1038/s41591-019-0715-9 · Cited by 790 · cited 1×
“Instead of predicting the model for electrochemical biosensor, the optical imaging method assisted by a convolutional neural network (CNN) was also developed to calculate the diagnostic consequences [14].”
MethodFrom squiggle to basepair: computational approaches for improving nanopore sequencing read accuracy
Rang, F. J., Kloosterman, W. P., & de Ridder, J. (2018) · Genome Biology · doi:10.1186/s13059-018-1462-9 · Cited by 672
Deep learning and artificial intelligence methods for Raman and surface-enhanced Raman scattering
Lussier, F., Thibault, V., Charron, B., Wallace, G. Q., & Masson, J.-F. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115796 · Cited by 666
Shin, H., Oh, S., Hong, S., Kang, M., Kang, D., Ji, Y.-G., Choi, B. H., Kang, K.-W., Jeong, H., Park, Y., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b09119 · Cited by 506
A transfer learning method with deep residual network for pediatric pneumonia diagnosis
Liang, G., & Zheng, L. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.06.023 · Cited by 491
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring
Kallenberg, M., Petersen, K., Nielsen, M., Ng, A. Y., Diao, P., Igel, C., Vachon, C. M., Holland, K., Winkel, R. R., Karssemeijer, N., et al. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2532122 · Cited by 439
Differentiation of bacterial and viral pneumonia in children
Virkki, R. (2002) · Thorax · doi:10.1136/thorax.57.5.438 · Cited by 382
Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acid
Chen, X., Wu, G., Cai, Z., Oyama, M., & Chen, X. (2014) · Microchimica Acta · doi:10.1007/s00604-013-1098-0 · Cited by 366
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
An Improved Photovoltaic Power Forecasting Model With the Assistance of Aerosol Index Data
Liu, J., Fang, W., Zhang, X., & Yang, C. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2381224 · Cited by 349
Liu, Q., Fang, L., Yu, G., Wang, D., Xiao, C.-L., & Wang, K. (2019) · Nature Communications · doi:10.1038/s41467-019-10168-2 · Cited by 324
Deep learning for vibrational spectral analysis: Recent progress and a practical guide
Yang, J., Xu, J., Zhang, X., Wu, C., Lin, T., & Ying, Y. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.012 · Cited by 299
Capacitance-modulated transistor detects odorant binding protein chiral interactions
Mulla, M. Y., Tuccori, E., Magliulo, M., Lattanzi, G., Palazzo, G., Persaud, K., & Torsi, L. (2015) · Nature Communications · doi:10.1038/ncomms7010 · Cited by 244
Arduini, F., Ricci, F., Tuta, C. S., Moscone, D., Amine, A., & Palleschi, G. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.07.052 · Cited by 241
Globally Coherent Text Generation with Neural Checklist Models
Kiddon, C., Zettlemoyer, L., & Choi, Y. (2016) · Proceedings of the 2016 Conference on Empirical Methods in Natural Language Processing · doi:10.18653/v1/d16-1032 · Cited by 219
Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection
Parrilla, M., Cuartero, M., Padrell Sánchez, S., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04877 · Cited by 209
Support Vector Machines: A Recent Method for Classification in Chemometrics
Yun Xu, A., Zomer, S., & Brereton, R. G. (2006) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600969486 · Cited by 206
Khosla, A., Shah, S., Shiblee, M. N. I., Mir, S. H., Nagahara, L. A., Thundat, T. G., Shekar, P. K., Kawakami, M., & Furukawa, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-30846-3 · Cited by 206
Self-citationRushworth, J. V., Ahmed, A., Griffiths, H. H., Pollock, N. M., Hooper, N. M., & Millner, P. A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.12.036 · Cited by 195
Self-citationBiosensing technology for sustainable food safety
Scognamiglio, V., Arduini, F., Palleschi, G., & Rea, G. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.07.007 · Cited by 192
Castillo, G., Spinella, K., Poturnayová, A., Šnejdárková, M., Mosiello, L., & Hianik, T. (2015) · Food Control · doi:10.1016/j.foodcont.2014.12.008 · Cited by 183
Review—Recent Advances in Tin Oxide Nanomaterials as Electrochemical/Chemiresistive Sensors
Sharma, A., Ahmed, A., Singh, A., Oruganti, S. K., Khosla, A., & Arya, S. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abdee8 · Cited by 177
Self-citationImaging Neuronal Activity with Genetically Encoded Calcium Indicators
Tian, L., Hires, S. A., & Looger, L. L. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top069609 · Cited by 173
Fast and Robust Training of Recurrent Neural Networks for Offline Handwriting Recognition
Doetsch, P., Kozielski, M., & Ney, H. (2014) · International Conference on Frontiers in Handwriting Recognition · doi:10.1109/icfhr.2014.54 · Cited by 169
Viswanathan, S., Rani, C., Vijay Anand, A., & Ho, J.-A. A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.006 · Cited by 167
Fluorescent-protein biosensors: New tools for drug discovery
Giuliano, K. A., & Taylor, D. L. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01166-9 · Cited by 164
Recent advances in nanowires-based field-effect transistors for biological sensor applications
Ahmad, R., Mahmoudi, T., Ahn, M.-S., & Hahn, Y.-B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.024 · Cited by 162
Recent developments in potentiometric biosensors for biomedical analysis
Koncki, R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.08.003 · Cited by 158
Sheng, Y., Zhang, T., Zhang, S., Johnston, M., Zheng, X., Shan, Y., Liu, T., Huang, Z., Qian, F., Xie, Z., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113027 · Cited by 155
Strambini, L. M., Longo, A., Scarano, S., Prescimone, T., Palchetti, I., Minunni, M., Giannessi, D., & Barillaro, G. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.11.010 · Cited by 148
Orij, R., Urbanus, M. L., Vizeacoumar, F. J., Giaever, G. N., Boone, C. M., Nislow, C., Brul, S., & Smits, G. J. (2012) · Genome biology · doi:10.1186/gb-2012-13-9-r80 · Cited by 148
Jampasa, S., Wonsawat, W., Rodthongkum, N., Siangproh, W., Yanatatsaneejit, P., Vilaivan, T., & Chailapakul, O. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.023 · Cited by 147
Zhu, X., Liu, P., Xue, T., Ge, Y., Ai, S., Sheng, Y., Wu, R., Xu, L., Tang, K., & Wen, Y. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.08.121 · Cited by 136
Casalini, S., Dumitru, A. C., Leonardi, F., Bortolotti, C. A., Herruzo, E. T., Campana, A., de Oliveira, R. F., Cramer, T., Garcia, R. A., & Biscarini, F. (2015) · ACS Nano · doi:10.1021/acsnano.5b00136 · Cited by 130
Wearable potentiometric tattoo biosensor for on-body detection of G-type nerve agents simulants
Mishra, R. K., Barfidokht, A., Karajić, A., Sempionatto, J. R., Wang, J., & Wang, J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.001 · Cited by 129
Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
Suprun, E. V., Evtugyn, G. A., Budnikov, H. C., Ricci, F., Moscone, D., & Palleschi, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0002-0 · Cited by 127
A novel automated flow-based biosensor for the determination of organophosphate pesticides in milk
Mishra, R. K., Dominguez, R. B., Bhand, S., Muñoz, R., & Marty, J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.028 · Cited by 127
Ahmad, R., Khan, M., Mishra, P., Jahan, N., Ahsan, M. A., Ahmad, I. N., Khan, M. R., Watanabe, Y., Syed, M. A., Furukawa, H., et al. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abd515 · Cited by 126
Self-citationTahir, A., Chowdhury, M. E. H., Khandakar, A. A., Al-Hamouz, S., Abdalla, M., Awadallah, S., Reaz, M. B. I., & Al-Emadi, N. A. (2020) · Sensors · doi:10.3390/s20040957 · Cited by 125
Comparison of sensing strategies in SPR biosensor for rapid and sensitive enumeration of bacteria
Torun, Ö., Boyacı, İ. H., Temür, E., & Tamer, U. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.04.034 · Cited by 124
Escherichia coli detection in vegetable food by a potentiometric biosensor
Ercole, C., Gallo, M. D., Mosiello, L., Baccella, S., & Lepidi, A. A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00083-2 · Cited by 123
Lee, M., Zine, N., Baraket, A., Zabala, M., Campabadal, F., Caruso, R., Trivella, M. G., Jaffrezic-Renault, N. J., & Errachid, A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.04.090 · Cited by 122
Application of Enzyme Biosensors in Analysis of Food and Beverages
Monošík, R., Streďanský, M., Tkáč, J., & Šturdík, E. (2011) · Food Analytical Methods · doi:10.1007/s12161-011-9222-4 · Cited by 120
Yang, G., Huang, J., Meng, W.-J., et al. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.008 · Cited by 114
Dies, H., Raveendran, J., Escobedo, C., et al. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.10.181 · Cited by 112
Monitoring the aging of beers using a bioelectronic tongue
Ghasemi‐Varnamkhasti, M., Rodríguez-Méndez, M. L., Mohtasebi, S. S., Apetrei, C., Lozano, J., Ahmadi, H., Razavi, S. H., & de Saja, J. A. (2011) · Food Control · doi:10.1016/j.foodcont.2011.10.020 · Cited by 110
Scognamiglio, V., Pezzotti, G., Pezzotti, I., Cano-Quintero, J. B., Buonasera, K., Giannini, D., & Giardi, M. T. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0313-5 · Cited by 109
Tucci, M., Grattieri, M., Schievano, A., Cristiani, P., & Minteer, S. D. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.02.007 · Cited by 103
Machine learning-based design of meta-plasmonic biosensors with negative index metamaterials
Moon, G., Choi, J., Lee, C., Oh, Y.-J., Kim, K. H., & Kim, D. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112335 · Cited by 100
Synthesis of Au–SnO2 nanoparticles for electrochemical determination of vitamin B12
Sharma, A., Arya, S. K., Chauhan, D., Solanki, P. R., Khajuria, S., & Khosla, A. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2020.10.024 · Cited by 100
Self-citationMultiple Feature Integration for Classification of Thoracic Disease in Chest Radiography
Ho, T. K., & Gwak, J. (2019) · Applied Sciences · doi:10.3390/app9194130 · Cited by 96
Support vector machine for optical diagnosis of cancer
Majumder, S. K., Ghosh, N., & Gupta, P. K. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1897396 · Cited by 95
Brain Tumor Segmentation Using a Fully Convolutional Neural Network with Conditional Random Fields
Zhao, X., Wu, Y., Song, G., Li, Z., Yong Fan, A., & Zhang, Y. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-55524-9_8 · Cited by 94
Ooi, K., GALATOWICZ, G. E., Towler, H. M. A., Lightman, S., & Calder, V. L. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0790 · Cited by 93
Barberis, A., Spissu, Y., Fadda, A., Azara, E., Bazzu, G., Marceddu, S., Angioni, A., Sanna, D., Schirra, M., & Serra, P. A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.019 · Cited by 92
Gold Nanoparticle-Modified Carbon Electrode Biosensor for the Detection of Listeria monocytogenes
Davis, D., Guo, X., Musavi, L. S., Lin, C., Chen, S.-H., & Wu, V. C. H. (2013) · Industrial Biotechnology · doi:10.1089/ind.2012.0033 · Cited by 90
Dynamic analysis of cytosolic glucose and ATP levels in yeast using optical sensors
Bermejo, C., Haerizadeh, F., Takanaga, H., Chermak, D., & Frommer, W. B. (2010) · Biochemical Journal · doi:10.1042/bj20100946 · Cited by 90
Development of bacteria-based bioassays for arsenic detection in natural waters
Diesel, E., Schreiber, M. E., & van der Meer, J. R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2785-x · Cited by 90
Thrift, W. J., & Ragan, R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03599 · Cited by 89
Green synthesis of high conductivity silver nanoparticle-reduced graphene oxide composite films
Dinh, D. A., Hui, K. S., Hui, K. S., Cho, Y. R., Zhou, W., Hong, X., & Chun, H.-H. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.01.101 · Cited by 88
Genome-Wide Analysis Reveals the Vacuolar pH-Stat of Saccharomyces cerevisiae
Brett, C. L., Kallay, L. M., Hua, Z., Green, R. R., Chyou, A., Zhang, Y., Graham, T. R., Donowitz, M., & Rao, R. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017619 · Cited by 88
Papp, S., Bojtár, M., Gyurcsányi, R. E., & Lindfors, T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01587 · Cited by 83
Morris, M. C. (2009) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-009-9070-7 · Cited by 82
Tram, N. D. T., Wang, H., Sugiarto, S., Li, T., Ang, W. H., Lee, C., & Pastorin, G. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.09.003 · Cited by 80
Imaging and Oncologic Drug Development
El‐Deiry, W. S., Sigman, C. C., & Kelloff, G. J. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.5623 · Cited by 78
Doty, K. C., & Lednev, I. K. (2017) · Forensic Science International · doi:10.1016/j.forsciint.2017.11.033 · Cited by 78
Watson, C. J., Ledwidge, M. T., Phelan, D. M. J., Collier, P. H., Byrne, J. C., Dunn, M. J., McDonald, K., & Baugh, J. A. (2011) · Circulation Heart Failure · doi:10.1161/circheartfailure.110.952200 · Cited by 76
Novel fluorescent proteins for high-content screening
Wolff, M., Wiedenmann, J., Nienhaus, G. U., Valler, M. J., & Heilker, R. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.09.005 · Cited by 73
Cinti, S., Arduini, F., Moscone, D., Palleschi, G., Gonzalez‐Macia, L., & Killard, A. J. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.054 · Cited by 70
Fluorescent biosensors — Probing protein kinase function in cancer and drug discovery
Morris, M. C. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.01.025 · Cited by 68
Goyal, M., Goyal, R., Reddy, P. V. R. K., & Lall, B. (2019) · Studies in computational intelligence · doi:10.1007/978-3-030-31760-7_1 · Cited by 67
Rea, G., Polticelli, F., Antonacci, A., Scognamiglio, V., Katiyar, P., Kulkarni, S. A., Johanningmeier, U., & Giardi, M. T. (2009) · Protein Science · doi:10.1002/pro.228 · Cited by 64
A Portable Nitrate Biosensing Device Using Electrochemistry and Spectroscopy
Vakilian, K. A., & Massah, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2809493 · Cited by 64
Maalouf, R., Chébib, H., Saïkali, Y., Vittori, O., Sigaud, M., & Jaffrezic-Renault, N. J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.11.003 · Cited by 61
Engineered CuO Nanofibers with Boosted Non-Enzymatic Glucose Sensing Performance
Khan, M., Nagal, V., Nakate, U. T., Khan, M. R., Khosla, A., & Ahmad, R. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ac030d · Cited by 61
Self-citationCaruso, R., Trunfio, S., Milazzo, F., Campolo, J., Maria, R. D., Colombo, T., Parolini, M., Cannata, A., Russo, C., Paino, R., et al. (2010) · ASAIO Journal · doi:10.1097/mat.0b013e3181de3049 · Cited by 58
Helali, S., Martelet, C., Abdelghani, A., Maaref, M. A., & Jaffrezic-Renault, N. J. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.03.086 · Cited by 58
Review—Recent Advances in the Development of Carbon Nanotubes Based Flexible Sensors
Kumar, S., Pavelyev, V. S., Tripathi, N., Платонов, В. И., Sharma, P., Ahmad, R., Mishra, P., & Khosla, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab7331 · Cited by 55
Self-citationMariani, S., Scarano, S., Spadavecchia, J., & Minunni, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.071 · Cited by 54
Zhao, L., Han, H., & Ma, Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.10.041 · Cited by 54
Gupta, J., Arya, S. K., Verma, S., Singh, A., Sharma, A., Singh, B., Prerna, P., & Sharma, R. K. (2019) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2019.121969 · Cited by 48
Self-citationReal-Time Speech Enhancement Using Equilibriated RNN
Takeuchi, D., Yatabe, K., Koizumi, Y., Oikawa, Y., & Harada, N. (2020) · ICASSP 2020 - 2020 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp40776.2020.9054597 · Cited by 48
Caruso, R., Verde, A., Cabiati, M., Milazzo, F., Boroni, C., Ry, S. D., Parolini, M., Vittori, C., Paino, R., Martinelli, L., et al. (2012) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.02.006 · Cited by 45
In vivobiochemistry: quantifying ion and metabolite levels in individual cells or cultures of yeast
Bermejo, C., Ewald, J. C., Lanquar, V., Jones, A. M., & Frommer, W. B. (2011) · Biochemical Journal · doi:10.1042/bj20110428 · Cited by 42
Corbett, P., & Boyle, J. (2018) · Database · doi:10.1093/database/bay066 · Cited by 40
Atomic Layer Deposited Hafnium Oxide Gate Dielectrics for Charge-Based Biosensors
Chen, Y. W., Liu, M., Kaneko, T., & McIntyre, P. C. (2010) · Electrochemical and Solid-State Letters · doi:10.1149/1.3280224 · Cited by 38
Amine oxidase-based biosensors for spermine and spermidine determination
Boffi, A., Favero, G., Federico, R., Macone, A., Antiochia, R., Tortolini, C., Sanzò, G., & Mazzei, F. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8324-4 · Cited by 36
Cánovas, R., Blondeau, P., & Andrade, F. J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112302 · Cited by 35
Classification of Machine Learning Algorithms
Taherdoost, H. (2022) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-981-16-8403-6_38 · Cited by 33
Carceller, J. M., Mifsud, M., Climent, M. J., Iborra, S., & Corma, A. (2020) · Green Chemistry · doi:10.1039/c9gc04127c · Cited by 32
Quantitative imaging using genetically encoded sensors for small molecules in plants
Okumoto, S. (2012) · The Plant Journal · doi:10.1111/j.1365-313x.2012.04910.x · Cited by 31
Chen, Y., Dong, F., Chun-yuan, B., Si-rong, Z., & Jian-guo, S. (2014) · Journal of Northeast Agricultural University (English edition) · doi:10.1016/s1006-8104(15)30023-4 · Cited by 30
Zhu, N., Lin, Y., Yu, P., Su, L., & Mao, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.05.017 · Cited by 29
Lee, M., Baraket, A., Zine, N., Zabala, M., Campabadal, F., Caruso, R., Trivella, M. G., Jaffrezic-Renault, N. J., & Errachid, A. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-0928-5_5 · Cited by 29
TOMASSETTI, M., Serone, M., Angeloni, R., Campanella, L., & Mazzone, E. (2015) · Sensors · doi:10.3390/s150203435 · Cited by 22
A New Low-Temperature Electrochemical Hydrocarbon and NOx Sensor
Sekhar, P. K., Moore, Z., Aravamudhan, S., & Khosla, A. (2017) · Sensors · doi:10.3390/s17122759 · Cited by 21
Self-citationGold-Coated Superparamagnetic Nanoparticles for Single Methyl Discrimination in DNA Aptamers
Tintoré, M., Mazzini, S., Polito, L., Marelli, M., Latorre, A., Somoza, Á., Aviñó, A. M., Fàbrega, C., & Eritja, R. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161126046 · Cited by 18
Circular Permutation of the Green Fluorescent Protein
Topell, S., & Glockshuber, R. (2003) · Humana Press eBooks · doi:10.1385/1-59259-280-5:031 · Cited by 18
Template Based Electrochemical Synthesis of Copper (Cu) Nanowires as CH2Cl2 Sensor
Gupta, J., Arya, S. K., Singh, A., Verma, S., Sharma, A., Singh, B., & Tomar, A. (2020) · Integrated ferroelectrics · doi:10.1080/10584587.2019.1674990 · Cited by 8
Self-citationPreparation and Characterization of Imunosensors for Disease Diagnosis
Ferreira, A. A. P., Fugivara, C. S., Yamanaka, H., & Vicente, A. (2011) · InTech eBooks · doi:10.5772/17265 · Cited by 6
Research works printed but not linked: 58
- Khosla, A. (2011). Micropatternable Multifunctional Nanocomposite Polymers for Flexible Soft MEMS Applications. [Ph.D. Thesis, Applied Science: School of Engineering Science, Simon Fraser University].
- Ahmad, 2020, Hydrothermally synthesiz0ed nickel oxide nanosheets for non-enzymatic electrochemical glucose detection, J. Electrochem. Soc., 167, 107504, 10.1149/1945-7111/ab9757 · doi:10.1149/1945-7111/ab9757
- Chullasat, 2011, Ultra trace analysis of small molecule by label-free impedi-metric immunosensor using multilayer modified electrode, Biosens. Bioelectron., 26, 4571, 10.1016/j.bios.2011.05.029 · doi:10.1016/j.bios.2011.05.029
- Canbaz, 2014, Electrochemical biosensor based on self-assembled monolayersmodifi ed with gold nanoparticles for detection of HER-3, Anal Chim. Acta., 814, 31, 10.1016/j.aca.2014.01.041 · doi:10.1016/j.aca.2014.01.041
- Kim, 2009, An impedimetric biosensor for real-time monitoring of bacterial growth in a microbial fermentor, Sens. Actuators B Chem., 138, 270, 10.1016/j.snb.2009.01.034 · doi:10.1016/j.snb.2009.01.034
- Srisomwat, 2020, Pop-up paper electrochemical device for label-free hepatitis B virus DNA detection, Sens. Actuators B Chem., 316, 128077, 10.1016/j.snb.2020.128077 · doi:10.1016/j.snb.2020.128077
- Sannini, 2015, An amperometric biosensor for the determination of lactic acid during malolactic fermentation, Chem. Eng. Trans., 44, 283
- Ciriello, 2015, Quantification of l-lysine in cheese by a novel amperometric biosensor, Food Chem., 169, 13, 10.1016/j.foodchem.2014.07.141 · DOI
- Habtamu, 2015, Miniaturized Enzymatic Biosensor via Biofunctionalization of the Insulator of Nanoelectrode Ensembles, Electroanalysis, 27, 2187, 10.1002/elan.201500115 · doi:10.1002/elan.201500115
- Malvano, 2015, Ethanol content in must grape by alcohol dehydrogenase biosensors based on doped Polyaniline modified screen printed electrodes, Chem. Eng. Trans., 43, 37
- Tortolini, 2016, Inhibition-based biosensor for atrazine detection, Sens. Actuators B Chem., 224, 552, 10.1016/j.snb.2015.10.095 · doi:10.1016/j.snb.2015.10.095
- Grattieri, 2015, Enzymatic Oxygen Microsensor Based on Bilirubin Oxidase Applied to Microbial Fuel Cells Analysis, Electroanalysis, 27, 327, 10.1002/elan.201400543 · DOI
- Silletti, 2015, An optical biosensor based on a multiarray of enzymes for monitoring a large set of chemical classes in milk, Sens. Actuators B Chem., 215, 607, 10.1016/j.snb.2015.03.092 · doi:10.1016/j.snb.2015.03.092
- Chiavaioli, 2015, Sol-Gel-Based Titania-Silica Thin Film Overlay for Long Period Fiber Grating-Based Biosensors, Anal. Chem., 87, 12024, 10.1021/acs.analchem.5b01841 · doi:10.1021/acs.analchem.5b01841
- Tardivo, 2015, Parallel optical read-out of micromechanical pillars applied to prostate specific membrane antigen detection, Biosens. Bioelectron., 72, 393, 10.1016/j.bios.2015.05.026 · doi:10.1016/j.bios.2015.05.026
- Scarano, 2015, Design of a dual aptamer-based recognition strategy for human matrix metalloproteinase 9 protein by piezoelectric biosensors, Anal. Chim. Acta, 897, 1, 10.1016/j.aca.2015.07.009 · doi:10.1016/j.aca.2015.07.009
- Ravalli, 2015, A label-free electrochemical affisensor for cancer marker detection: The case of HER2, Bioelectrochemistry, 106, 268, 10.1016/j.bioelechem.2015.07.010 · doi:10.1016/j.bioelechem.2015.07.010
- Benetti, 2015, A surface acoustic wave bio-electronic nose for detection of volatile odorant molecules, Biosens. Bioelectron., 67, 516, 10.1016/j.bios.2014.09.027 · doi:10.1016/j.bios.2014.09.027
- Cennamo, N., Giovanni, S.D., Varriale, A., Staiano, M., Di Pietrantonio, F., Notargiacomo, A., Zeni, L., and D’Auria, S. (2015). Easy to use plastic optical fiber-based biosensor for detection of butanal. PLoS ONE, 10. · doi:10.1371/journal.pone.0116770
- Compagnone, 2015, Quartz crystal microbalance gas sensor arrays for the quality control of chocolate, Sens. Actuators B Chem., 207, 1114, 10.1016/j.snb.2014.10.049 · doi:10.1016/j.snb.2014.10.049
- Zuccaro, 2015, Real-Time Label-Free Direct Electronic Monitoring of Topoisomerase Enzyme Binding Kinetics on Graphene, ACS Nano, 9, 11166, 10.1021/acsnano.5b05709 · doi:10.1021/acsnano.5b05709
- Lacina, 2018, Biosensing based on electrochemical impedance spectroscopy: Influence of the often-ignored molecular charge, Electrochem. Commun., 93, 183, 10.1016/j.elecom.2018.07.015 · doi:10.1016/j.elecom.2018.07.015
- Raoof, 2015, Genosensor for Point Mutation Detection of P53 Gene PCR Product Using Magnetic Particles, Electroanalysis, 27, 1378, 10.1002/elan.201400660 · doi:10.1002/elan.201400660
- Wu, 2017, Gold nanoparticles dotted reduction Graphene oxide Nanocomposite based electrochemical Aptasensor for selective, rapid, sensitive and congener-specific PCB77 detection, Sci. Rep., 7, 1
- Rodriguez, 2002, Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline–poly (n-butyl methacrylate) composites, Sens. Actuators B: Chem., 85, 19, 10.1016/S0925-4005(02)00045-X · doi:10.1016/s0925-4005(02)00045-x
- Li, 2011, Fabrication and testing of thermally responsive hydrogel-based actuators using polymer heater elements for flexible microvalves, Microfluidics, BioMEMS, and Medical Microsystems IX, Volume 7929, 79290G-1
- Ahmad, 2014, High performance cholesterol sensor based on ZnO nanotubes grown on Si/Ag electrodes, Electrochem. Commun., 38, 4, 10.1016/j.elecom.2013.10.028 · doi:10.1016/j.elecom.2013.10.028
- Ahmad, 2013, High-performance cholesterol sensor based on the solution-gated field effect transistor fabricated with ZnO nanorods, Biosens. Bioelectron., 45, 281, 10.1016/j.bios.2013.01.021 · doi:10.1016/j.bios.2013.01.021
- Wang, 2012, Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods, Talanta, 94, 263, 10.1016/j.talanta.2012.03.037 · doi:10.1016/j.talanta.2012.03.037
- Batra, 2015, ZnO-CuO composite matrix based reagentless biosensor for detection of total cholesterol, Biosens. Bioelectron., 67, 263, 10.1016/j.bios.2014.08.029 · doi:10.1016/j.bios.2014.08.029
- Oh, 2016, An ultrasensitive and incubation-free electrochemicalimmunosensor using a gold-nanocatalyst label mediating outer-spherereaction-philic and inner-sphere-reaction-philic species, Chem. Commun., 52, 5884, 10.1039/C6CC00353B · doi:10.1039/c6cc00353b
- Cai, 2016, Ratiometric electrochemical immunoassay based on internalreference value for reproducible and sensitive detection of tumor marker, Biosens. Bioelectron., 81, 173, 10.1016/j.bios.2016.02.066 · doi:10.1016/j.bios.2016.02.066
- Zhang, 2016, A novel electrochemical immunosensor based onnonenzymatic Ag@au-Fe3O4 nanoelectrocatalyst for protein biomarkerdetection, Biosens. Bioelectron., 85, 343, 10.1016/j.bios.2016.04.100 · doi:10.1016/j.bios.2016.04.100
- Xu, 2007, Biosensor based on self-assembling glucose oxidase and Dendrimer-encapsulated Pt nanoparticles on carbon nanotubes for glucosedetection, Electroanalysis, 19, 717, 10.1002/elan.200603805 · doi:10.1002/elan.200603805
- Gupta, 2017, Ultrasensitive transglutaminase based nanosensor for early detection of celiac dis- ease in human, Int. J. Biol. Macromol., 105, 905, 10.1016/j.ijbiomac.2017.07.126 · doi:10.1016/j.ijbiomac.2017.07.126
- Neves, 2012, Celiac disease detection using a transglutaminase electro-chemical immunosensor fabricated on nanohybrid screen-printed carbon electrodes, Biosens. Bioelectron., 31, 95, 10.1016/j.bios.2011.09.044 · doi:10.1016/j.bios.2011.09.044
- Hianik, 2005, Detection of aptamer—protein interactions using QCM and electrochemical indicator methods, Bioorg. Med. Chem., 15, 291, 10.1016/j.bmcl.2004.10.083 · doi:10.1016/j.bmcl.2004.10.083
- Arya, 2019, Comparative study of CuO, CuO@ Ag and CuO@ Ag: La nanoparticles for their photosensing properties, Mater. Res. Express, 6, 116313, 10.1088/2053-1591/ab49ab · doi:10.1088/2053-1591/ab49ab
- Marks, R.S., and Abdulhalim, I. (2015). Nanomaterials for Water Management: Signal Amplification for Biosensing from Nanostructures, CRC Press. · doi:10.1201/b18715
- Ly, 2011, Diagnosis of Helicobacter pylori bacterial infections using a voltammetric biosensor, J. Microbiol. Methods, 87, 44, 10.1016/j.mimet.2011.07.002 · doi:10.1016/j.mimet.2011.07.002
- Wang, J. (2006). Analytical Electrochemistry Hoboken, John Wiley & Sons, Inc.
- Elshafey, 2013, Electrochemical impedance immunosensor based on gold nanoparticles—protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue, Biosens. Bioelectron., 50, 143, 10.1016/j.bios.2013.05.063 · doi:10.1016/j.bios.2013.05.063
- Seven, 2013, Impedimetric biosensor for cancer cell detection, Electrochem. Commun., 37, 36, 10.1016/j.elecom.2013.10.003 · doi:10.1016/j.elecom.2013.10.003
- Chowdhury, 2012, Label free polyaniline based impedimetric biosensor for detection of E. coli O157: H7 Bacteria, Sens. Actuators B Chem., 171, 916, 10.1016/j.snb.2012.06.004 · doi:10.1016/j.snb.2012.06.004
- Shirsat, 2007, Amperometric glucose biosensor on layer bylayer assembled carbon nanotube and Polypyrrole multilayer film, Electroanalysis, 20, 150, 10.1002/elan.200704028 · doi:10.1002/elan.200704028
- Jakhar, 2018, Preparation, characterization and application of urease nanoparticles for construction of an improved potentiometric urea biosensor, Biosens. Bioelectron., 100, 242, 10.1016/j.bios.2017.09.005 · doi:10.1016/j.bios.2017.09.005
- Singh, 2021, Promising photocatalytic degradation of methyl orange dye via sol-gel synthesized Ag–CdS@ Pr-TiO2 core/shell nanoparticles, Phys. B Condens. Matter, 616, 413121, 10.1016/j.physb.2021.413121 · doi:10.1016/j.physb.2021.413121
- Chung, 2013, Investigations of flexible Ag/AgCl nanocomposite polymer electrodes for suitability in tissue electrical impedance scanning (EIS), J. Electrochem. Soc., 161, B3071, 10.1149/2.018402jes · doi:10.1149/2.018402jes
- Singh, A., Arya, S., Khanuja, M., Hafiz, A.K., Datt, R., Gupta, V., and Khosla, A. (2020). Eu doped NaYF 4@ Er: TiO 2 nanoparticles for tunable ultraviolet light based anti-counterfeiting applications. Microsyst. Technol., 1–10. · doi:10.1007/s00542-019-04734-3
- Choi, 1998, Evaluation of two types of biosensors for immunoassay of botulinum toxin, J. Biochem. Mol. Biol., 31, 101
- Gaffar, 2017, Voltammetric DNA biosensor using gold electrode modified by self assembled monolayer of Thiol for detection of mycobacterium tuberculosis, Procedia Technol., 27, 74, 10.1016/j.protcy.2017.04.034 · doi:10.1016/j.protcy.2017.04.034
- Jamal, 2018, A non enzymatic glutamate sensor based on nickel oxide nanoparticle, Microsyst. Technol., 24, 4217, 10.1007/s00542-018-3724-6 · doi:10.1007/s00542-018-3724-6
- Wang, 2017, Detection of extremely low concentration waterborne pathogen using a multiplexing selfreferencing SERS microfluidic biosensor, J. Biol. Eng., 11, 9, 10.1186/s13036-017-0051-x · doi:10.1186/s13036-017-0051-x
- Olano, 2015, The influence of sky conditions on the standardized calibration of pyranometers and on the measurement of global solar irradiation, Sol. Energy, 121, 116, 10.1016/j.solener.2015.07.031 · doi:10.1016/j.solener.2015.07.031
- Massah, 2013, An artificial neural network approach to identify fungal diseases of cucumber (Cucumis sativus L.) plants using digital image processing, Arch. Phytopathol. Plant Protect., 46, 1580, 10.1080/03235408.2013.772321 · doi:10.1080/03235408.2013.772321
- Bailer, C., Habtegebrial, T., Varanasi, K., and Stricker, D. (2018). Fast Feature Extraction with CNNs with Pooling Layers. arXiv.
- Lipton, Z.C., Berkowitz, J., and Elkan, C. (2015). A critical review of recurrent neural networks for sequence learning. arXiv.
- Williams, J.D., and Zweig, G. (2016). End-to-end lstm-based dialog control optimized with supervised and reinforcement learning. arXiv.
Cited by
Umapathi, R., Ghoreishian, S. M., Sonwal, S., Rani, G. M., & Huh, Y. S. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214305 · Cited by 547
Nanomaterials-based biosensor and their applications: A review
Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e19929 · Cited by 441
Metadata
- Authors
- Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2021-09-14
- Volume
- 11
- Issue
- 9
- Pages
- 336
- ISSN
- 2079-6374 (ISSN-L)
- OpenAlex
- W3200063015
- Cited by
- 579
- References
- 117
- FWCI
- 23.26
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Japan Society for the Promotion of Science (JP17H01224, JP18H0547, JP19H01122)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.