Biofilm Detection by a Fiber-Tip Ball Resonator Optical Fiber Sensor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Bacterial biofilms are one of the most important challenges that modern medicine faces due to the difficulties of diagnosis, antibiotic resistance, and protective mechanisms against aggressive environments. For these reasons, methods that ensure the inexpensive and rapid or real-time detection of biofilm formation on medical devices are needed. This study examines the possibilities of using optical- and fiber-based biosensors to detect and analyze early bacterial biofilms. In this study, the biofilm-forming model organism Pseudomonas aeruginosa was inoculated on the surface of the optical sensor and allowed to attach for 2 h. The biosensors were made by a fiber-tip ball resonator, fabricated through a CO2 laser splicer on a single-mode fiber, forming a weak reflective spectrum. An optical backscatter reflectometer was used to measure the refractive index detected by the sensors during different growth periods. The early biofilm concentration was determined by crystal violet (CV) binding assay; however, such a concentration was lower than the detection limit of this assay. This work presents a new approach of biofilm sensing in the early attachment stage with a low limit of detection up to 10−4 RIU (refractive index units) or 35 ± 20 × 103 CFU/mL (colony formed units).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent improvements in fiber-tip ball resonator optical fiber sensors and speckle analysis provide accurate capabilities for biofilm identification [360,361].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [360]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proctor, R. A., von Eiff, C., Kahl, B. C., Becker, K., McNamara, P., Herrmann, M., & Peters, G. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1384 · Cited by 1,175
Research works printed but not linked: 38
- Venkatesan, 2015, Bacterial resistance in biofilm-associated bacteria, Future Microbiol., 10, 1743, 10.2217/fmb.15.69 · DOI · Paper page
- Bryers, 2008, Medical biofilms, Biotechnol. Bioeng., 100, 1, 10.1002/bit.21838 · DOI · Paper page
- Hassan, 2011, Evaluation of different detection methods of biofilm formation in the clinical isolates, Braz. J. Infect. Dis., 15, 305, 10.1016/S1413-8670(11)70197-0 · DOI · Paper page
- Costerton, 2004, Bacterial biofilms: From the Natural environment to infectious diseases, Nat. Rev. Genet., 2, 95, 10.1038/nrmicro821 · DOI · Paper page
- Rohanizadegan, 2020, Discrete attachment to a cellulolytic biofilm modeled by an Itô stochastic differential equation, Math. Biosci. Eng., 17, 2236, 10.3934/mbe.2020119 · DOI
- Monroe, D. (2007). Looking for Chinks in the Armor of Bacterial Biofilms. PLoS Biol., 5. · DOI · Paper page
- Xu, 2019, Sensing the unreachable: Challenges and opportunities in biofilm detection, Curr. Opin. Biotechnol., 64, 79, 10.1016/j.copbio.2019.10.009 · DOI · Paper page
- Motta, 2021, Gastrointestinal biofilms in health and disease, Nat. Rev. Gastroenterol. Hepatol., 18, 314, 10.1038/s41575-020-00397-y · DOI · Paper page
- Bjarnsholt, 2018, Biofilm formation—What we can learn from recent developments, J. Intern. Med., 284, 332, 10.1111/joim.12782 · DOI
- Luis, 2018, Expert Review of Anti-infective Therapy Biofilm-related disease, Expert Rev. Anti-Infect. Ther., 16, 51, 10.1080/14787210.2018.1417036 · DOI · Paper page
- Shresthar, 2018, Comparative evaluation of methods for the detection of biofilm formation in coagulase-negative staphylococci and correlation with antibiogram, Infect. Drug Resist., 11, 607, 10.2147/IDR.S159764 · DOI
- Houpikian, 2002, Traditional and Molecular Techniques for the Study of Emerging Bacterial Diseases: One Laboratory’s Perspective, Emerg. Infect. Dis., 8, 122, 10.3201/eid0802.010141 · DOI
- Huber, 2008, Light scattering by small particles, J. Water Supply Res. Technol., 47, 87, 10.1046/j.1365-2087.1998.00086.x · doi:10.1046/j.1365-2087.1998.00086.x
- Meyers, 2018, Direct optical density determination of bacterial cultures in microplates for high-throughput screening applications, Enzym. Microb. Technol., 118, 1, 10.1016/j.enzmictec.2018.06.016 · DOI
- Kurmoo, 2020, Real time monitoring of biofilm formation on coated medical devices for the reduction and interception of bacterial infections, Biomater. Sci., 8, 1464, 10.1039/C9BM00875F · DOI
- Yuan, 2016, Electrochemical Surface Plasmon Resonance Fiber-Optic Sensor: In Situ Detection of Electroactive Biofilms, Anal. Chem., 88, 7609, 10.1021/acs.analchem.6b01314 · DOI
- Guo, T., González-Vila, Á., Loyez, M., and Caucheteur, C. (2017). Plasmonic Optical Fiber-Grating Immunosensing: A Review. Sensors, 17. · DOI
- Chiavaioli, F., Gouveia, C.A.J., Jorge, P.A.S., and Baldini, F. (2017). Towards a Uniform Metrological Assessment of Grating-Based Optical Fiber Sensors: From Refractometers to Biosensors. Biosensors, 7. · DOI
- Santano, 2019, Trends in the design of wavelength-based optical fibre biosensors (2008–2018), Biosens. Bioelectron. X, 1, 100015
- Mallik, 2018, Whispering gallery mode micro resonators for multi-parameter sensing applications, Opt. Express, 26, 31829, 10.1364/OE.26.031829 · doi:10.1364/oe.26.031829
- Chiasera, 2009, Spherical whispering-gallery-mode microresonators, Laser Photon.-Rev., 4, 457, 10.1002/lpor.200910016 · DOI · Paper page
- Li, 2021, Optimization, fabrication, and performance analysis of SMF-/MMF-based microfiber ball structure, Appl. Opt., 60, 1196, 10.1364/AO.417358 · doi:10.1364/ao.417358
- Sumetsky, 2010, Optical microbubble resonator, Opt. Lett., 35, 898, 10.1364/OL.35.000898 · DOI
- Bekmurzayeva, 2021, Label-free fiber-optic spherical tip biosensor to enable picomolar-level detection of CD44 protein, Sci. Rep., 11, 19583, 10.1038/s41598-021-99099-x · doi:10.1038/s41598-021-99099-x
- Ayupova, 2021, Picomolar detection of thrombin with fiber-optic ball resonator sensor using optical backscatter reflectometry, Optik, 241, 166969, 10.1016/j.ijleo.2021.166969 · DOI
- Ayupova, 2019, Fiber Optic Refractive Index Distributed Multi-Sensors by Scattering-Level Multiplexing with MgO Nanoparticle-Doped Fibers, IEEE Sens. J., 20, 2504, 10.1109/JSEN.2019.2953231 · doi:10.1109/jsen.2019.2953231
- Shaimerdenova, M., Ayupova, T., Sypabekova, M., and Tosi, D. (2020). Fiber Optic Refractive Index Sensors Based on a Ball Resonator and Optical Backscatter Interrogation. Sensors, 20. · doi:10.3390/s20216199
- Jiang, 2020, Whispering-Gallery Sensors, Matter, 3, 371, 10.1016/j.matt.2020.07.008 · DOI · Paper page
- Xu, 2021, Development of a novel label-free all-fiber optofluidic biosensor based on Fresnel reflection and its applications, Anal. Chim. Acta, 1181, 338910, 10.1016/j.aca.2021.338910 · DOI
- LaBauve, 2012, Growth and Laboratory Maintenance of Pseudomonas aeruginosa, Curr. Protoc. Microbiol., 25, 6E.1.1, 10.1002/9780471729259.mc06e01s25 · DOI · Paper page
- Shukla, S.K., and Rao, T.S. (2017). An Improved Crystal Violet Assay for Biofilm Quantification in 96-Well Microtitre Plate. Biorxiv, 100214. · DOI
- Manandhar, S., Singh, A., Varma, A., Pandey, S., and Shrivastava, N. (2018). Evaluation of methods to detect in vitro biofilm formation by staphylococcal clinical isolates. BMC Res. Notes, 11. · DOI
- Adetunji, 2011, Crystal violet binding assay for assessment of biofilm formation by Listeria monocytogenes and Listeria spp on wood, steel and glass surfaces, Glob. Vet., 6, 6
- Kragh, 2019, Into the well—A close look at the complex structures of a microtiter biofilm and the crystal violet assay, Biofilm, 1, 100006, 10.1016/j.bioflm.2019.100006 · DOI · Paper page
- Peeters, 2008, Comparison of multiple methods for quantification of microbial biofilms grown in microtiter plates, J. Microbiol. Methods, 72, 157, 10.1016/j.mimet.2007.11.010 · DOI · Paper page
- Amador, 2021, High-throughput screening alternative to crystal violet biofilm assay combining fluorescence quantification and imaging, J. Microbiol. Methods, 190, 106343, 10.1016/j.mimet.2021.106343 · DOI
- Auman, 2014, A Textbook That Gets Students Excited about Microbiology. Review of: Microbiology: An Evolving Science, 3rd ed.; SlonczewskiJoan, L. and FosterJohn, W.; ( 2014). W.W. Norton & Company, Inc., New York, NY. 1184 pages, J. Microbiol. Biol. Educ., 15, 60, 10.1128/jmbe.v15i1.711 · doi:10.1128/jmbe.v15i1.711
- Kim, 2012, Relation of microbial biomass to counting units for Pseudomonas aeruginosa, Afr. J. Microbiol. Res., 6, 4620
Cited by
Understanding bacterial biofilms: From definition to treatment strategies
Zhao, A., Sun, J., & Liu, Y. (2023) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2023.1137947 · Cited by 743
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
Metadata
- Authors
- Rakhimbekova, A., Kudaibergenov, B., Moldabay, D., Zharylgap, A., Ajunwa, O. M., Marsili, E., & Tosi, D.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2022-06-30
- Volume
- 12
- Issue
- 7
- Pages
- 481
- ISSN
- 2079-6374
- Cited by
- 17
- References
- 1
- Language
- en
- Funders
- Nazarbayev University (091019CRP2117, 021220CRP0522, 240919FD3908)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biofilm Detection by a Fiber-Tip Ball Resonator Optical Fiber Sensor. https://app.cochat.ai/papers/10.3390/bios12070481
- The paper
- Rakhimbekova, A., Kudaibergenov, B., Moldabay, D., Zharylgap, A., Ajunwa, O. M., Marsili, E., & Tosi, D. (2022). Biofilm Detection by a Fiber-Tip Ball Resonator Optical Fiber Sensor. Biosensors. https://doi.org/10.3390/bios12070481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.