Detection of Cardiac Biomarkers Using Single Polyaniline Nanowire-Based Conductometric Biosensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The detection of myoglobin (Myo), cardiac troponin I (cTnI), creatine kinase-MB (CK-MB), and b-type natriuretic peptide (BNP) plays a vital role in diagnosing cardiovascular diseases. Here we present single site-specific polyaniline (PANI) nanowire biosensors that can detect cardiac biomarkers such as Myo, cTnI, CK-MB, and BNP with ultra-high sensitivity and good specificity. Using single PANI nanowire-based biosensors integrated with microfluidic channels, very low concentrations of Myo (100 pg/mL), cTnI (250 fg/mL), CK-MB (150 fg/mL), and BNP (50 fg/mL) were detected. The single PANI nanowire-based biosensors displayed linear sensing profiles for concentrations ranging from hundreds (fg/mL) to tens (ng/mL). In addition, devices showed a fast (few minutes) response satisfying respective reference conditions for Myo, cTnI, CK-MB, and BNP diagnosis of heart failure and for determining the stage of the disease. This single PANI nanowire-based biosensor demonstrated superior biosensing reliability with the feasibility of label free detection and improved processing cost efficiency due to good biocompatibility of PANI to monoclonal antibodies (mAbs). Therefore, this development of single PANI nanowire-based biosensors can be applied to other biosensors for cancer or other diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Charge Sensitivity of Silicon Nanowires: Size Dependence
Elfström, N., Juhasz, R., Sychugov, I., Engfeldt, T., Karlström, A. E., & Linnros, J. (2007) · Nano Letters · doi:10.1021/nl0709017 · Cited by 275
Cited by
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers
Fathil, M. F. M., Md Arshad, M. K., Gopinath, S. C. B., Hashim, U., Adzhri, R., Ayub, R. M., Ruslinda, A. R., Nuzaihan M.N., M., Azman, A. H., Zaki, M., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.037 · Cited by 277
Futuristic biosensors for cardiac health care: an artificial intelligence approach
Vashistha, R., Dangi, A. K., Kumar, A., Chhabra, D., & Shukla, P. (2018) · 3 Biotech · doi:10.1007/s13205-018-1368-y · Cited by 113
Supraja, P., Sudarshan, V., Tripathy, S., Agrawal, A., & Singh, S. G. (2019) · Analytical Methods · doi:10.1039/c8ay02617c · Cited by 45
Metadata
- Authors
- Lee, I., Luo, X., Huang, J., Cui, X. T., & Yun, M.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2012-05-14
- Volume
- 2
- Issue
- 2
- Pages
- 205-220
- ISSN
- 2079-6374 (ISSN-L)
- OpenAlex
- W2049592197
- Cited by
- 124
- References
- 1
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.