The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Advances in biosensors: Principle, architecture and applications
Abstract
The ability to detect pathogenic and physiologically relevant molecules in the body with high sensitivity and specificity offers a powerful opportunity in the early diagnosis and treatment of diseases. Early detection and diagnosis can be used to greatly reduce the cost of patient care associated with the advanced stages of many diseases. However, despite their widespread clinical use, these techniques have a number of potential limitations. For example, a number of diagnostic devices have slow response times and are burdensome to patients. Furthermore, these assays are expensive and cost the health care industry billions of dollars every year. Therefore, there is a need to develop more efficient and reliable sensing and detection technologies. A biosensor is commonly defined as an analytical device that uses a biological recognition system to target molecules or macromolecules. Biosensors can be coupled to a physiochemical transducer that converts this recognition into a detectable output signal. Typically biosensors are comprised of three components: (1) the detector, which identifies the stimulus; (2) the transducer, which converts this stimulus to a useful output; and (3) the signal processing system, which involves amplification and display of the output in an appropriate format. The goal of this combination is to utilize the high sensitivity and selectivity of biological sensing for analytical purposes in various fields of research and technology. We review here some of the main advances in this field over the past few years, explore the application prospects, and discuss the issues, approaches, and challenges, with the aim of stimulating a broader interest in developing biosensors and improving their applications in medical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Cited by
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Supraja, P., Sudarshan, V., Tripathy, S., Agrawal, A., & Singh, S. G. (2019) · Analytical Methods · doi:10.1039/c8ay02617c · Cited by 45
Nanomaterial-based electrochemical biosensors for food safety and quality assessment
Dridi, F., Marrakchi, M., Gargouri, M., Saulnier, J., Jaffrezic-Renault, N., & Lagarde, F. (2017) · Nanobiosensors · doi:10.1016/b978-0-12-804301-1.00005-9 · Cited by 40
Metadata
- Authors
- Perumal, V., & Hashim, U.
- Venue
- Journal of Applied Biomedicine
- Published
- 2014-01-01
- Volume
- 12
- Issue
- 1
- Pages
- 1-15
- ISSN
- 1214-021X (ISSN-L)
- 1214-0287
- OpenAlex
- W2062982252
- Cited by
- 606
- References
- 1
- FWCI
- 17.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in biosensors: Principle, architecture and applications. https://app.cochat.ai/papers/10.1016/j.jab.2013.02.001
- The paper
- Perumal, V., & Hashim, U. (2014). Advances in biosensors: Principle, architecture and applications. Journal of Applied Biomedicine. https://doi.org/10.1016/j.jab.2013.02.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.