The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications
Open accessAbstract
As electrochemical measuring instruments, screen-printed electrodes (SPEs) are constructed via a technology called thick film deposition onto plastic or ceramic substrates, allowing for simple, inexpensive, and rapid on-site analysis with high reproducibility, sensitivity, and accuracy. Numerous substances such as gold, silver, platinum, and carbon are applied for electrode construction, enabling the analyst to design the best device based on its purpose to determine an analyte’s selectivity and sensitivity. Thus, in the current review, we report the latest results and analyses conducted over the past eight years (2015–2022) on the expansion of SPE electrochemical biosensors, including aptasensors, immunosensors, DNA sensors, and enzymatic biosensors. Such expansion has resulted in new possibilities for the identification, distinction, and quantification of biocompounds, drugs, enzymes, etc. Therefore, in this paper, we review the role of different nanomaterials in manufacturing on-screen electrode methods as well as strategies for the future stable diagnosis of biorecognition elements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098
Electrochemical Biosensors: Recommended Definitions and Classification
Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S. (1999) · Pure and Applied Chemistry · doi:10.1351/pac199971122333 · Cited by 909
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Graphene based materials for biomedical applications
Yang, Y., Asiri, A. M., Tang, Z., Du, D., & Lin, Y. (2013) · Materials Today · doi:10.1016/j.mattod.2013.09.004 · Cited by 653
Recent developments in the field of screen-printed electrodes and their related applications
Renedo, O. D., Alonso-Lomillo, M. A., & Martínez, M. J. A. (2007) · Talanta · doi:10.1016/j.talanta.2007.03.050 · Cited by 647
Banks, C. E., Crossley, A., Salter, C., Wilkins, S. J., & Compton, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200600033 · Cited by 618
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Recent developments and applications of screen-printed electrodes in environmental assays—A review
Li, M., Li, Y.-T., Li, D.-W., & Long, Y.-T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.018 · Cited by 550
Metadata
- Authors
- Paimard, G., Ghasali, E., & Baeza, M.
- Venue
- Chemosensors
- Publisher
- MDPI AG
- Published
- 2023-02-03
- Volume
- 11
- Issue
- 2
- Pages
- 113
- ISSN
- 2227-9040 (ISSN-L)
- OpenAlex
- W4319318392
- Cited by
- 255
- References
- 106
- FWCI
- 18.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications. https://app.cochat.ai/papers/10.3390/chemosensors11020113
- The paper
- Paimard, G., Ghasali, E., & Baeza, M. (2023). Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications. Chemosensors. https://doi.org/10.3390/chemosensors11020113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.