Digital Triplet Approach for Real-Time Monitoring and Control of an Elevator Security System
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
As Digital Twins gain more traction and their adoption in industry increases, there is a need to integrate such technology with machine learning features to enhance functionality and enable decision making tasks. This has lead to the emergence of a concept known as Digital Triplet; an enhancement of Digital Twin technology through the addition of an ’intelligent activity layer’. This is a relatively new technology in Industrie 4.0 and research efforts are geared towards exploring its applicability, development and testing of means for implementation and quick adoption. This paper presents the design and implementation of a Digital Triplet for a three-floor elevator system. It demonstrates the integration of a machine learning (ML) object detection model and the system Digital Twin. This was done to introduce an additional security feature that enabled the system to make a decision, based on objects detected and take preliminary security measures. The virtual model was designed in Siemens NX and programmed via Total Integrated Automation (TIA) portal software. The corresponding physical model was fabricated and controlled using a Programmable Logic Controller (PLC) S7 1200. A control program was developed to mimic the general operations of a typical elevator system used in a commercial building setting. Communication, between the physical and virtual models, was enabled using the OPC-Unified Architecture (OPC-UA) protocol. Object recognition using “You only look once” (YOLOV3) based machine learning algorithm was incorporated. The Digital Triplet’s functionality was tested, ensuring the virtual system duplicated actual operations of the physical counterpart through the use of sensor data. Performance testing was done to determine the impact of the ML module on the real-time functionality aspect of the system. Experiment results showed the object recognition contributed an average of 1.083 s to an overall signal travel time of 1.338 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Twin in manufacturing: A categorical literature review and classification
Kritzinger, W., Karner, M., Traar, G., Henjes, J., & Sihn, W. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.08.474 · Cited by 3,612
Digital twin-driven product design, manufacturing and service with big data
Tao, F., Cheng, J., Qi, Q., Zhang, M., Zhang, H., & Sui, F. (2018) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-017-0233-1 · Cited by 2,920
Digital twin and big data towards smart manufacturing and Industry 4.0: 360 degree comparison
Qi, Q., & Tao, F. (2018) · IEEE Access · doi:10.1109/access.2018.2793265 · Cited by 1,716
Digital twin shop-floor: a new shop-floor paradigm towards smart manufacturing
Tao, F., & Zhang, M. (2017) · IEEE Access · doi:10.1109/access.2017.2756069 · Cited by 1,397 · cited 2×
“Integration of such features into the Digital Twin technology has been explored in various manufacturing scenarios, as demonstrated by [15–18].”
MethodThe Digital Twin: Realizing the Cyber-Physical Production System for Industry 4.0
Uhlemann, T. H.-J., Lehmann, C., & Steinhilper, R. (2017) · Procedia CIRP · doi:10.1016/j.procir.2016.11.152 · Cited by 994
Diez-Olivan, A., Del Ser, J., Galar, D., & Sierra, B. (2019) · Information Fusion · doi:10.1016/j.inffus.2018.10.005 · Cited by 633
The modelling and operations for the digital twin in the context of manufacturing
Bao, J., Guo, D., Li, J., & Zhang, J. (2019) · Enterprise Information Systems · doi:10.1080/17517575.2018.1526324 · Cited by 347
Plug-and-Simulate within Modular Assembly Line enabled by Digital Twins and the use of AutomationML
Um, J., Weyer, S., & Quint, F. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2360 · Cited by 88 · cited 1×
“When integrated in CPS most Digital Twin applications include but are not limited to, layout planning, preventive maintenance and production planning and control [7,9,10].”
Background
Cited by
Digital twin: origin to future
Singh, M., Fuenmayor, E., Hinchy, E., Qiao, Y., Murray, N., & Devine, D. (2021) · Applied System Innovation · doi:10.3390/asi4020036 · Cited by 1,038
Warke, V., Kumar, S., Bongale, A., & Kotecha, K. (2021) · Sustainability · doi:10.3390/su131810139 · Cited by 103
Reinpold, L. M., Wagner, L. P., Gehlhoff, F., Ramonat, M., Kilthau, M., Gill, M. S., Reif, J. T., Henkel, V., Scholz, L., & Fay, A. (2025) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-023-02278-y · Cited by 27
Metadata
- Authors
- Gichane, M. M., Byiringiro, J. B., Chesang, A. K., Nyaga, P. M., Langat, R. K., Smajic, H., & Kiiru, C. W.
- Venue
- Designs
- Publisher
- MDPI AG
- Published
- 2020-04-21
- Volume
- 4
- Issue
- 2
- Pages
- 9
- ISSN
- 2411-9660 (ISSN-L)
- OpenAlex
- W3018835799
- Cited by
- 41
- References
- 8
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.