Artificial Intelligence-Enhanced Smartwatch ECG for Heart Failure-Reduced Ejection Fraction Detection by Generating 12-Lead ECG
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: We developed and validated an artificial intelligence (AI)-enabled smartwatch ECG to detect heart failure-reduced ejection fraction (HFrEF). Methods: This was a cohort study involving two hospitals (A and B). We developed the AI in two steps. First, we developed an AI model (ECGT2T) to synthesize ten-lead ECG from the asynchronized 2-lead ECG (Lead I and II). ECGT2T is a deep learning model based on a generative adversarial network, which translates source ECGs to reference ECGs by learning styles of the reference ECGs. For this, we included adult patients aged ≥18 years from hospital A with at least one digitally stored 12-lead ECG. Second, we developed an AI model to detect HFrEF using a 10 s 12-lead ECG. The AI model was based on convolutional neural network. For this, we included adult patients who underwent ECG and echocardiography within 14 days. To validate the AI, we included adult patients from hospital B who underwent two-lead smartwatch ECG and echocardiography on the same day. The AI model generates a 10 s 12-lead ECG from a two-lead smartwatch ECG using ECGT2T and detects HFrEF using the generated 12-lead ECG. Results: We included 137,673 patients with 458,745 ECGs and 38,643 patients with 88,900 ECGs from hospital A for developing the ECGT2T and HFrEF detection models, respectively. The area under the receiver operating characteristic curve of AI for detecting HFrEF using smartwatch ECG was 0.934 (95% confidence interval 0.913–0.955) with 755 patients from hospital B. The sensitivity, specificity, positive predictive value, and negative predictive value of AI were 0.897, 0.860, 0.258, and 0.994, respectively. Conclusions: An AI-enabled smartwatch 2-lead ECG could detect HFrEF with reasonable performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Statistical Modeling: The Two Cultures (with comments and a rejoinder by the author)
Breiman, L. (2001) · Statistical Science · doi:10.1214/ss/1009213726 · Cited by 4,340
Groenewegen, A., Rutten, F. H., Mosterd, A., & Hoes, A. W. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1858 · Cited by 2,043 · cited 1×
“Despite advances in treatment, HF remains as a high risk of morbidity and mortality and is the most common diagnosis in hospitalized patients aged over 65 years, with a 5-year survival rate of only 57% [3–5].”
BackgroundLarge-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Heart Failure With Reduced Ejection Fraction: A Review
Murphy, S. P., Ibrahim, N. E., & Januzzi, J. L. (2020) · JAMA · doi:10.1001/jama.2020.10262 · Cited by 769 · cited 1×
“Despite its poor prognosis and high economic burden, HFrEF awareness remains relatively low due to its insidious onset, varied presentation, and syndromic nature [8].”
BackgroundPassive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566 · cited 1×
“As there is a possibility of decreasing performance in daily living at home, we needed to validate this AI in a home setting [25].”
BackgroundPre-symptomatic detection of COVID-19 from smartwatch data
Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00640-6 · Cited by 463
Jonas, D. E., Reddy, S., Middleton, J. C., Barclay, C., Green, J., Baker, C., & Asher, G. N. (2018) · JAMA · doi:10.1001/jama.2018.6897 · Cited by 78 · cited 1×
“Electrocardiography (ECG) is a low-cost test frequently performed for a variety of purposes, especially basic examination and screening for cardio-vascular disease [10].”
Background
Cited by
Smart Wearables for the Detection of Cardiovascular Diseases: A Systematic Literature Review
Moshawrab, M., Adda, M., Bouzouane, A., Ibrahim, H., & Raad, A. (2023) · Sensors · doi:10.3390/s23020828 · Cited by 120
Moving towards vertically integrated artificial intelligence development
Zhang, J., Budhdeo, S., William, W., Cerrato, P., Shuaib, H., Sood, H., Ashrafian, H., Halamka, J., & Teo, J. T. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00690-x · Cited by 54
Artificial intelligence and the electrocardiogram: A modern renaissance
Palermi, S., Vecchiato, M., Ng, F. S., Attia, Z., Cho, Y., Anselmino, M., De Ferrari, G. M., Saglietto, A., Sau, A., Chiu, I.-M., et al. (2025) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2025.04.036 · Cited by 42
Automated HFrEF Diagnosis Using an Optimized TimeSformer Model in Echocardiography
Petmezas, G., Papageorgiou, V. E., Vassilikos, V., Pagourelias, E., Tachmatzidis, D., Tsaklidis, G., Katsaggelos, A. K., & Maglaveras, N. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01758-2 · Cited by 3
Metadata
- Authors
- Kwon, J.-M., Jo, Y.-Y., Lee, S. Y., Kang, S., Lim, S.-Y., Lee, M. S., & Kim, K.-H.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2022-03-08
- Volume
- 12
- Issue
- 3
- Pages
- 654
- ISSN
- 2075-4418 (ISSN-L)
- OpenAlex
- W4220683353
- Cited by
- 51
- References
- 10
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.