The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A Review of Heating and Temperature Control in Microfluidic Systems: Techniques and Applications
Open accessAbstract
This review presents an overview of the different techniques developed over the last decade to regulate the temperature within microfluidic systems. A variety of different approaches has been adopted, from external heating sources to Joule heating, microwaves or the use of lasers to cite just a few examples. The scope of the technical solutions developed to date is impressive and encompasses for instance temperature ramp rates ranging from 0.1 to 2,000 °C/s leading to homogeneous temperatures from −3 °C to 120 °C, and constant gradients from 6 to 40 °C/mm with a fair degree of accuracy. We also examine some recent strategies developed for applications such as digital microfluidics, where integration of a heating source to generate a temperature gradient offers control of a key parameter, without necessarily requiring great accuracy. Conversely, Temperature Gradient Focusing requires high accuracy in order to control both the concentration and separation of charged species. In addition, the Polymerase Chain Reaction requires both accuracy (homogeneous temperature) and integration to carry out demanding heating cycles. The spectrum of applications requiring temperature regulation is growing rapidly with increasingly important implications for the physical, chemical and biotechnological sectors, depending on the relevant heating technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and elitist multiobjective genetic algorithm: NSGA-II
Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T. (2002) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.996017 · Cited by 50,053
Multi-Objective Optimization Using Evolutionary Algorithms
Deb, K., & Kalyanmoy, D. (2001) · Andalas University Repository (Andalas University) · Cited by 14,918
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 1×
“However, micromixing in chambers remains challenging even though many in-line micromixers have been developed and successfully demonstrated [32,34].”
BackgroundElectrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Temperature Measurement in Microfluidic Systems Using a Temperature-Dependent Fluorescent Dye
Ross, D., Gaitan, M., & Locascio, L. E. (2001) · Analytical Chemistry · doi:10.1021/ac010370l · Cited by 631
The impact of microwave synthesis on drug discovery
Kappe, C. O., & Dallinger, D. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1926 · Cited by 610
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
A Short History of the Polymerase Chain Reaction
Bartlett, J. M. S., & Stirling, D. (2003) · PCR Protocols · doi:10.1007/978-1-4612-0055-0_1 · Cited by 420
Microfluidic Temperature Gradient Focusing
Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac025528w · Cited by 278
Multiplexed Real-Time Polymerase Chain Reaction on a Digital Microfluidic Platform
Hua, Z., Rouse, J. L., Eckhardt, A. E., Srinivasan, V., Pamula, V. K., Schell, W. A., Benton, J. L., Mitchell, T. G., & Pollack, M. G. (2010) · Analytical Chemistry · doi:10.1021/ac902510u · Cited by 248
Darhuber, A. A., Valentino, J. P., Troian, S. M., & Wagner, S. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820267 · Cited by 240
Soret Effect in Interacting Micellar Solutions
Piazza, R., & Guarino, A. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.208302 · Cited by 216
Photopatternable Conductive PDMS Materials for Microfabrication
Cong, H., & Pan, T. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701437 · Cited by 191
Cofabrication of Electromagnets and Microfluidic Systems in Poly(dimethylsiloxane)
Siegel, A. C., Shevkoplyas, S. S., Weibel, D. B., Bruzewicz, D. A., Martinez, A. W., & Whitesides, G. M. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602273 · Cited by 131
A microfluidic device based on droplet storage for screening solubility diagrams
Laval, P., Lisai, N., Salmon, J., & Joanicot, M. (2007) · Lab on a Chip · doi:10.1039/b700799j · Cited by 117
Thermocapillary actuation of liquid flow on chemically patterned surfaces
Darhuber, A. A., Davis, J. M., Troian, S. M., & Reisner, W. (2003) · Physics of Fluids · doi:10.1063/1.1562628 · Cited by 114
Thermally mediated control of liquid microdroplets at a bifurcation
Fatt, Y. Y., Tan, S. H., Nguyen, N., Murshed, S. M. S., Wong, T. N., & Yobaş, L. (2009) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/42/6/065503 · Cited by 107
Polydimethylsiloxane microfluidic chip with integrated microheater and thermal sensor
Wu, J., Cao, W., Wen, W., et al. (2009) · Biomicrofluidics · doi:10.1063/1.3058587 · Cited by 100
Petri dish PCR: laser-heated reactions in nanoliter droplet arrays
Kim, H., Vishniakou, S., & Faris, G. W. (2009) · Lab on a Chip · doi:10.1039/b817288a · Cited by 89
Optically driven fluid flow along arbitrary microscale patterns using thermoviscous expansion
Weinert, F. M., & Braun, D. (2008) · Journal of Applied Physics · doi:10.1063/1.3026526 · Cited by 72
Selva, B., Mirallès, V., Cantat, I., & Jullien, M.-C. (2010) · Lab on a Chip · doi:10.1039/c001900c · Cited by 70
Self-citationA large volume, portable, real-time PCR reactor
Qiu, X., Mauk, M. G., Chen, D., Liu, C., & Bau, H. H. (2010) · Lab on a Chip · doi:10.1039/c0lc00038h · Cited by 55
Temperature gradient focusing in a PDMS/glass hybrid microfluidic chip
Matsui, T., Franzke, J., Manz, A., & Janasek, D. (2007) · Electrophoresis · doi:10.1002/elps.200700272 · Cited by 52
Maltezos, G., Johnston, M. L., Taganov, K. D., Srichantaratsamee, C., Gorman, J., Baltimore, D., Chantratita, W., & Scherer, A. (2010) · Applied Physics Letters · doi:10.1063/1.3530452 · Cited by 49
Orrling, K. M., Nilsson, P., Gullberg, M. T., & Larhed, M. (2004) · Chemical Communications · doi:10.1039/b317049g · Cited by 48
Manufacturable plastic microfluidic valves using thermal actuation
Pitchaimani, K., Sapp, B. C., Winter, A., Gispanski, A., Nishida, T., & Fan, Z. H. (2009) · Lab on a Chip · doi:10.1039/b909742b · Cited by 43
Rapid microfluidic thermal cycler for polymerase chain reaction nucleic acid amplification
Mahjoob, S., Vafai, K., & Beer, N. R. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2007.11.014 · Cited by 43
Molecular Probes for Thermometry in Microfluidic Devices
Gosse, C., Bergaud, C., & Löw, P. (2009) · Topics in applied physics · doi:10.1007/978-3-642-04258-4_10 · Cited by 39
Optical manipulation and control of real-time PCR in cell encapsulating microdroplets by IR laser
Hettiarachchi, K., Kim, H., & Faris, G. W. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-1016-5 · Cited by 38
Fast and accurate temperature control of a PCR microsystem with a disposable reactor
Dinca, M. P., Gheorghe, M., Aherne, M., & Galvin, P. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/6/065009 · Cited by 27
Cited by
A review of chemical gradient systems for cell analysis
Somaweera, H., Ibraguimov, A., & Pappas, D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.008 · Cited by 98
Metadata
- Authors
- Miralles, V., Huerre, A., Malloggi, F., & Jullien, M.-C.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2013-01-15
- Volume
- 3
- Issue
- 1
- Pages
- 33-67
- ISSN
- 2075-4418 (ISSN-L)
- OpenAlex
- W1997089536
- Cited by
- 284
- References
- 34
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.