CoChat

GaborPDNet: gabor transformation and deep neural network for Parkinson's disease detection using EEG signals

Open access
Loh, Hui Wen, Ooi, Chui Ping, Palmer, Elizabeth, Barua, Prabal Datta, Dogan, Sengul, Tuncer, Turker, Baygin, Mehmet, Acharya, U. Rajendra · 2021 · Electronics

The DOI matches its Crossref record; 58 of the 59 references it cites were found in a registry or an index.

Abstract

Parkinson’s disease (PD) is globally the most common neurodegenerative movement disorder. It is characterized by a loss of dopaminergic neurons in the substantia nigra of the brain. However, current methods to diagnose PD on the basis of clinical features of Parkinsonism may lead to misdiagnoses. Hence, noninvasive methods such as electroencephalographic (EEG) recordings of PD patients can be an alternative biomarker. In this study, a deep-learning model is proposed for automated PD diagnosis. EEG recordings of 16 healthy controls and 15 PD patients were used for analysis. Using Gabor transform, EEG recordings were converted into spectrograms, which were used to train the proposed two-dimensional convolutional neural network (2D-CNN) model. As a result, the proposed model achieved high classification accuracy of 99.46% (±0.73) for 3-class classification (healthy controls, and PD patients with and without medication) using tenfold cross-validation. This indicates the potential of proposed model to simultaneously automatically detect PD patients and their medication status. The proposed model is ready to be validated with a larger database before implementation as a computer-aided diagnostic (CAD) tool for clinical-decision support.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/electronics10141740

Cites

58 of 59 references verified0 citation errors · 1 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Figure 3 Workflow process from preprocessing of EEG recordings to classification by the proposed model. Figure 3. Workflow process from preprocessing of EEG recordings to classification by the proposed model.
Figure 3 Workflow process from preprocessing of EEG recordings to classification by the proposed model. Figure 3. Workflow process from preprocessing of EEG recordings to classification by the proposed model.CC-BY · From the PDF
Figure 4 Spectrograms of three respective groups of subjects. Figure 4. Spectrograms of three respective groups of subjects.
Figure 4 Spectrograms of three respective groups of subjects. Figure 4. Spectrograms of three respective groups of subjects.CC-BY · From the PDF
Figure 5 Model architecture of proposed 2D-CNN model. Figure 5. Model architecture of proposed 2D-CNN model.
Figure 5 Model architecture of proposed 2D-CNN model. Figure 5. Model architecture of proposed 2D-CNN model.CC-BY · From the PDF
Image 5
CC-BY · From the PDF
Figure 7 Cont.
Figure 7 Cont.CC-BY · From the PDF
Image 7
CC-BY · From the PDF
Workflow of cloud-based system to assist medical professionals to automatically detect PD using EEG recor Figure 8. Workflow of cloud-based system to assist medical professionals to automatically detect PD using EEG recordings.
Workflow of cloud-based system to assist medical professionals to automatically detect PD using EEG recor Figure 8. Workflow of cloud-based system to assist medical professionals to automatically detect PD using EEG recordings.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Research works printed but not linked: 1

  1. Scherzer, O., Ed.; Springer: New York, NY, USA, 2015; pp. 1717-1757. [CrossRef]

Cited by

See all 144

Metadata

Authors
Loh, H. W., Ooi, C. P., Palmer, E., Barua, P. D., Dogan, S., Tuncer, T., Baygin, M., & Acharya, U. R.
Affiliations
  • Singapore University of Social Sciences (SG)
  • UNSW Sydney (AU)
  • University of Technology Sydney (AU)
  • Department of Digital Forensics Engineering, College of Technology, Firat University, Elazig 23119, Turkey
  • Department of Computer Engineering, Faculty of Engineering, Ardahan University, Ardahan 75000, Turkey
  • Asia University (TW)
Corresponding author
Acharya, U. Rajendra
Venue
Electronics
Publisher
MDPI AG
Published
2021-07-20
Volume
10
Issue
14
Pages
1740
ISSN
2079-9292 (ISSN-L)
OpenAlex
W3185004711
Cited by
144
References
57
Citations by year
2026: 15 · 2025: 43 · 2024: 40 · 2023: 28 · 2022: 13 · 2021: 5
FWCI
11.30
Type
journal article
Language
en
Open access
Locations
  • Electronics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • DSpace - FIRAT (Fırat University) (submittedVersion, cc-by-nc-nd)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
Keywords
Parkinson's disease, EEG, Gabor transform, spectrogram, 2D convolutional neural network, automated diagnosis, computer-aided diagnosis, biomarkers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.