An Auto Adjustable Transimpedance Readout System for Wearable Healthcare Devices
Open accessAbstract
The objective of this work was to design a versatile readout circuit for patch-type wearable devices consisting of a Transimpedance Amplifier (TIA). The TIA performs Current to Voltage (I–V) conversion, the most widely used technique for amperometry and impedance measurement for various types of electrochemical sensors. The proposed readout circuit employs a digitally controllable feedback resistor (Rf) technique in the TIA to improve accuracy, which can be utilized in a variety of electrochemical sensors within a current range of 0.1 µA–100 µA. It is designed to accommodate multiple sensors simultaneously to track multiple target analytes for high accuracy and versatile usage. The readout circuit consists of low power operational amplifier (op–amp) and digital circuit blocks, is designed and fabricated with Magna 0.18 µm Complementary Metal Oxide Semiconductor (CMOS) technology, which provides low power consumption and a high degree of integration. The design has a small size of 0.282 mm2 and low power consumption of 0.38 mW with a 3.3 V power supply, which are desirable factors in wearable device applications.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861 · see citing works
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498 · see citing works
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326 · see citing works
A Technological Review of Wearable Cueing Devices Addressing Freezing of Gait in Parkinson’s Disease
Sweeney, D., Quinlan, L. R., Browne, P., Richardson, M., Meskell, P., & ÓLaighin, G. (2019) · Sensors · doi:10.3390/s19061277 · Cited by 103 · see citing works
Flagged first, then by citations
- Authors
- Park, H., Lakshminarayana, S., Pan, C., Chung, H.-J., & Jung, S.
- Affiliations
- The University of Texas at Arlington (US)
- Kumoh National Institute of Technology (KR)
- Corresponding author
- Chung, Hoon-Ju
- Jung, Sungyong
- Venue
- Electronics
- Publisher
- MDPI AG
- Published
- 2022-04-08
- Volume
- 11
- Issue
- 8
- Pages
- 1181
- ISSN
- 2079-9292 (ISSN-L)
- OpenAlex
- W4224223566
- Cited by
- 9
- References
- 4
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 1
- FWCI
- 0.58
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Electronics (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Kumoh National Institute of Technology (2018104115)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- transimpedance amplifier, readout circuit, wearable healthcare devices, current-to-voltage conversion, amperometric sensing, electrochemical sensor, low-power CMOS design, multi-analyte sensing, low-power operational amplifier
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review