Model Predictive Control (MPC) for Enhancing Building and HVAC System Energy Efficiency: Problem Formulation, Applications and Opportunities
Open accessThe DOI matches its Crossref record; 177 of the 178 references it cites were found in a registry or an index.
Abstract
In the last few years, the application of Model Predictive Control (MPC) for energy management in buildings has received significant attention from the research community. MPC is becoming more and more viable because of the increase in computational power of building automation systems and the availability of a significant amount of monitored building data. MPC has found successful implementation in building thermal regulation, fully exploiting the potential of building thermal mass. Moreover, MPC has been positively applied to active energy storage systems, as well as to the optimal management of on-site renewable energy sources. MPC also opens up several opportunities for enhancing energy efficiency in the operation of Heating Ventilation and Air Conditioning (HVAC) systems because of its ability to consider constraints, prediction of disturbances and multiple conflicting objectives, such as indoor thermal comfort and building energy demand. Despite the application of MPC algorithms in building control has been thoroughly investigated in various works, a unified framework that fully describes and formulates the implementation is still lacking. Firstly, this work introduces a common dictionary and taxonomy that gives a common ground to all the engineering disciplines involved in building design and control. Secondly the main scope of this paper is to define the MPC formulation framework and critically discuss the outcomes of different existing MPC algorithms for building and HVAC system management. The potential benefits of the application of MPC in improving energy efficiency in buildings were highlighted.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Numerous MPC studies have reported the potential to maintain the optimum/comfort range temperature while reducing energy consumption by 10-30% [7,14,15].”
From Energy-Saving Control Method for Factory Mushroom Room Air Conditioning Based on MPC (2023) · cites this paper as [15]
Citations
Cites
Control of systems integrating logic, dynamics, and constraints
Bemporad, A., & Morari, M. (1999) · Automatica · doi:10.1016/s0005-1098(98)00178-2 · Cited by 3,066 · cited 1×
“In this case, the optimization most commonly can be cast as a Mixed Integer Programming (MIP) problem, and the MPC formulation is commonly referred as hybrid MPC [54].”
Self-citationA review on the prediction of building energy consumption
Zhao, H.-X., & Magoulès, F. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.049 · Cited by 1,937 · cited 1×
“• Online predictions rely on the availability of an internet connection and the possibility to acquire forecasts from a third party modeling source, that can provide accurate prediction using complex models [50,57,60] (e.”
Camacho, E. F., & Bordons, C. (2007) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-0-85729-398-5 · Cited by 1,391
Theory and applications of HVAC control systems – A review of model predictive control (MPC)
Afram, A., & Janabi-Sharifi, F. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.016 · Cited by 1,310 · cited 3×
“To the best of authors’ knowledge, the work of Afram and Janabi-Sharifi [21] can be considered the most remarkable review on MPC due to the worthy scheme of MPC implementation that it offers, combined with clear classifications criteria.”
InfluentialUse of model predictive control and weather forecasts for energy efficient building climate control
Oldewurtel, F., Parisio, A., Jones, C. N., Gyalistras, D., Gwerder, M., Stauch, V., Lehmann, B., & Morari, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.09.022 · Cited by 1,222
Robust model predictive control: A survey
Bemporad, A., & Morari, M. (2007) · Lecture Notes in Control and Information Sciences · doi:10.1007/bfb0109870 · Cited by 1,066 · cited 1×
“An MPC is called robust MPC when the stability and the performance specifications are maintained for all possible model variations and a class of noise signals (uncertainty magnitude) within a specified range [48].”
Self-citationShaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866 · cited 2×
“Considering that usually indoor thermal comfort and building energy demand are contrasting needs, optimization procedures that aim at finding a trade-off between them are one of the primary goals of engineers and researchers worldwide [3].”
Dounis, A. I., & Caraiscos, C. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.015 · Cited by 851 · cited 2×
“The papers [10,39] are two preliminary surveys dealing with advanced control systems for energy and comfort management in buildings.”
State of the art in building modelling and energy performances prediction: A review
Foucquier, A., Robert, S., Suard, F., Stéphan, L., & Jay, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.004 · Cited by 832 · cited 1×
“The simplest method for offline predictions is based on a rule of thumb that states that “the conditions of the next hours would be only slightly different from those of the previous time period” [51,95,96].”
Experimental analysis of model predictive control for an energy efficient building heating system
Široký, J., Oldewurtel, F., Cigler, J., & Prívara, S. (2011) · Applied Energy · doi:10.1016/j.apenergy.2011.03.009 · Cited by 753 · cited 1×
“, boiler or heat pump response rate [112], valve/damper/pump/fan change rate [114]).”
Research works printed but not linked: 8
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) (2013). 2013 ASHRAE Handbook—Fundamentals (SI Edition), American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
- Curtiss, P.S. (July, January 28). Examples of Neural Networks Used for Building System Control and Energy Management. Proceedings of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Annual Meeting, Boston, MA, USA.
- Oldewurtel, F., Parisio, A., Jones, C.N., Morari, M., Gyalistras, D., Gwerder, M., Stauch, V., Lehmann, B., and Wirth, K. (July, January 30). Energy efficient building climate control using Stochastic Model Predictive Control and weather predictions. Proceedings of the American Control Conference (ACC), Baltimore, MD, USA.
- Dobre, C., and Xhafa, F. (2016). Enhancing energy efficiency in buildings through innovative data analytics technologies. Next Generation Platforms for Intelligent Data Collection, Elsevier.
- De Cursi, E.S., and Sampaio, R. (2015). Uncertainty Quantification and Stochastic Modeling with Matlab, ISTE Press—Elsevier. [1st ed.].
- Béguery, P., Industries, S., and Merlin, P.L. (2001, January 23–27). Model predictive control for energy management in buildings. Part 2: Distributed Model Predictive Control. Proceedings of the 4th IFAC Conference on Nonlinear Model Predictive Control, Noordwijkerhout, The Netherlands.
- Fanger, P. (1972). Thermal Comfort: Analysis and Applications in Environmental Engineering, McGraw-Hill.
- Cengel, Y.A., and Ghajar, A.J. (2014). Heat and Mass Transfer: Fundamentals and Applications, McGraw-Hill. [5th ed.].
Cited by
Items 401–500 of 674
Homod, R. Z., Mohammed, H. I., Sadeq, A. M., Alhasnawi, B. N., Al-Fatlawi, A. W., Rashid, F. L., Hussein, A. K., Alawi, O. A., Yadav, K. K., Togun, H., et al. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.113771 · Cited by 3
Achieving desirable control for non-inverter HVAC systems by dynamic set-temperature approach
Nia, M. F., Hu, E. J., & Ghayesh, M. H. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.104135 · Cited by 3
Sittas, K., Giama, E., & Panaras, G. (2025) · Energies · doi:10.3390/en19010066 · Cited by 3
Onwong’a, D., Kabeyi, M. J. B., Njoroge, K., & Olanrewaju, O. A. (2026) · Energies · doi:10.3390/en19040925 · Cited by 3
Zhang, H., Wang, Y., Zhao, H., Yao, W., Gao, W., Yang, G., Sun, L., & Jiang, Z. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114378 · Cited by 3
Li, G., O’Neill, Z. D., Fu, Y., & Pertzborn, A. J. (2026) · Applied Energy · doi:10.1016/j.apenergy.2026.127891 · Cited by 3
Chen, X., Li, X., Wang, W., Fu, Y., Wang, C., Pan, A., Li, Z., Zhou, Y., Lu, Y., Shi, Q., et al. (2026) · Renewable Energy · doi:10.1016/j.renene.2026.125902 · Cited by 4
Yu, Y., Lee, M., Lee, C., Cheon, Y., Baek, S., Kim, Y., Kim, K., Jung, H., Lim, D., Byun, H., et al. (2023) · Processes · doi:10.3390/pr11082229 · Cited by 3
Validation of a Model Predictive Control Strategy on a High Fidelity Building Emulator
Fop, D., Yaghoubi, A. R., & Capozzoli, A. (2024) · Energies · doi:10.3390/en17205117 · Cited by 5
“The MPC is a model-based controller that adjusts the input of a dynamic model to generate the optimal control strategy over a time frame that begins at the present and extends over a specified prediction horizon in the future [19,20].”
Self-citationHomod, R. Z., Mohammed, H. I., Dhaidan, N. S., Albahri, A. S., Al-Mousawi, F. N., Togun, H., Hussein, A. K., Alhasnawi, B. N., Rashid, F. L., & Yaseen, Z. M. (2025) · ASME Journal of Engineering for Sustainable Buildings and Cities · doi:10.1115/1.4069356 · Cited by 5
Cui, D., Mo, Y., Yuan, X., Ye, L., Wang, K., Shen, F., Wang, Y., Yang, C., & Gui, W. (2025) · Journal of Process Control · doi:10.1016/j.jprocont.2025.103542 · Cited by 3
gENESiS: Design, Operation and Integration of Smart Sustainable Buildings in Smart Power Grids
Avramidis, I.-I., Nagpal, H., Mehrtash, M., & Capitanescu, F. (2021) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med51440.2021.9480315 · Cited by 4
“In the context of buildings, MPC has been widely used in research on optimal operation of heating-ventilation-air-conditioning (HVAC) systems with various objectives such as reduction of energy cost, energy consumption, improvement of thermal comfort, peak-load shaving or achieving robustness against disturbances [9],…”
MethodLee, D., Ooka, R., Matsuda, Y., Ikeda, S., & Choi, W. (2021) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med51440.2021.9480324 · Cited by 5
A Comparative Review of Energy Management Controllers in Building
Ahmad, M., & Moubayed, N. (2021) · International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) · doi:10.1109/3ict53449.2021.9581665 · Cited by 3
Watari, D., Taniguchi, I., Catthoor, F., Marantos, C., Siozios, K., Shirazi, E., Soudris, D., & Onoye, T. (2022) · IEICE Transactions on Fundamentals of Electronics Communications and Computer Sciences · doi:10.1587/transfun.2022mai0001 · Cited by 3
Intelligent Model Hotel Energy Demand Forecasting by Means of LSTM and GRU Neural Networks
López, V., Casteleiro‐Roca, J., Gato, F. Z., Pérez, J. A. M., & ROLLE, J. L. C. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-23210-7_8 · Cited by 3
Дмитриевич, С. О. (2023) · Safety and Reliability of Power Industry · doi:10.24223/1999-5555-2023-16-2-73-78 · Cited by 3
Klinge, J., Wekerle, D., & Völtzer, K. (2023) · European Control Conference (ECC) · doi:10.23919/ecc57647.2023.10178369 · Cited by 3
“The application of optimal control in buildings, more precise model predictive control (MPC), has also increasingly been discussed in the scientific community [3], [4].”
BackgroundEnergy Efficiency Improvements Using a Rule-Based Look Ahead Controller for Mobile Air Conditioning
Palacio‐Torralba, J., Kapoor, S., Jaybhay, S. K., & Kulkarni, S. (2023) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2023-28-0009 · Cited by 3
Retracted: Deep learning-based energy inefficiency detection in the smart buildings
Huang, J., Koroteev, D. D., & Rynkovskaya, M. I. (2023) · Sustainable Computing Informatics and Systems · doi:10.1016/j.suscom.2023.100921 · Cited by 3
RetractedModel-based design of the temperature controller of a shrink tunnel
Previtali, D., Pitturelli, L., Ferramosca, A., & Previdi, F. (2024) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2024.08.312 · Cited by 4
“For example, the temperature controllers of HVAC systems must ensure a suitable level of indoor thermal comfort and minimize building energy demand while rejecting disparate disturbances, stemming from the climate, occupant behavior, and electrical grid fluctuations (Serale et al. (2018)).”
BackgroundPredictive and probabilistic modelling using machine learning for building indoor climate control
Abdufattokhov, S., Mahamatov, N., Ibragimova, K., & Gulyamova, D. (2022) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v26.i3.pp1306-1314 · Cited by 3
MPC Design for an Auditorium Building Using Data Driven Modeling
Paschke, F., Huang, C., & Seidel, S. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.09.079 · Cited by 2
Retracted: HVAC Hybrid Control methods for HEE in Buildings: Overview
Murade, G. B., Soni, B. P., & Mukherjee, A. (2021) · International Conference on Advances in Computing, Communication and Control (ICAC3) · doi:10.1109/icac353642.2021.9697201 · Cited by 2
RetractedIntelligent learning models for renewable energy forecasting
Jove, E., Michelena, Á., Timiraos, M., López, V., Quintián, H., & ROLLE, J. L. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15806-3.00005-x · Cited by 2
Esmaeilzadeh, A., & Hamdy, M. (2024) · IEEE International Conference on Smart Energy Grid Engineering (SEGE) · doi:10.1109/sege62220.2024.10739531 · Cited by 2
“Taking into account the role of Model Predictive Control (MPC) in building energy management [25], MPC has been developed based on a case study model and 1-year data simulation.”
MethodFlexibility Enhancement in Heat Pump-based Indoor Temperature MPC
Pepe, C., Ali, M. F., & Zanoli, S. M. (2024) · International Multi-Topic Conference · doi:10.1109/inmic64792.2024.11004345 · Cited by 2
“In the last years, MPC has been exploited also for enhancing buildings’ HVAC (Heating, Ventilation, and Air Conditioning) systems efficiency [1].”
Robust particle filtering-based nonlinear model predictive control: Application to PEMFC process
Zhang, Q., Lu, S., Xie, L., Su, H., & Shi, Y. (2025) · Chinese Journal of Chemical Engineering · doi:10.1016/j.cjche.2025.07.011 · Cited by 2
Hamda, A. S., Abo, L. D., Arumugasamy, S. K., & Jayakumar, M. (2025) · Process Integration and Optimization for Sustainability · doi:10.1007/s41660-025-00562-3 · Cited by 3
“Another review by Serale et al. (2018) focused on control problem formulation and highlighted computational complexity; this review expands on this by analyzing hardware acceleration and model order reduction techniques as emerging solutions.”
InfluentialAdaptive Control Design for Dual EV Charging Using Triple Active Bridge (TAB) Converter
Ahmad, A., Chelvan, I. T., & Hassan, W. (2025) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie62713.2025.11124717 · Cited by 2
Kalidindi, S. S. V., Banaee, H., Karlsson, H., & Loutfi, A. (2025) · Energy and AI · doi:10.1016/j.egyai.2025.100603 · Cited by 2
AI-enabled building energy model generation and domain randomization for control policy learning
Kuo, T. C., Manikkan, S., Liu, X., Devarapalli, H., Bilionis, I., & Karava, P. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113815 · Cited by 4
Extension and validation of a simplified building thermal comfort model
Lotfabadi, A. K., & Marshall, J. S. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116819 · Cited by 2
Esmaeilzadeh, A., Deal, B. M., & Hamdy, M. (2026) · Energy Reports · doi:10.1016/j.egyr.2026.109049 · Cited by 3
Wu, Q., Ni, Y., Fang, Z., Liu, S. W., & Jiang, Y. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117099 · Cited by 2
Ontology-driven digital twins for optimized recommissioning of hospital building operations
Thomsen, A., Bjørnskov, J., & Jradi, M. (2026) · Journal of Building Engineering · doi:10.1016/j.jobe.2026.115627 · Cited by 2
Alotaibi, B. S. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117268 · Cited by 2
Guan, L., Mark, D., Künzel, H. M., & Wallis, L. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117380 · Cited by 2
Optimal decoupling control of VAV air conditioning based on analytic method
Chen, D., Gong, Y., Chen, J., & He, R. (2026) · Journal of Building Engineering · doi:10.1016/j.jobe.2026.115928 · Cited by 3
Control strategies for HVAC systems
Kardos, T., Kutasi, D. N., & György, K. (2019) · IEEE International Symposium on Computational Intelligence and Informatics (CINTI) · doi:10.1109/cinti-macro49179.2019.9105198 · Cited by 2
A Supervisory Model Predictive Control Framework for Dual Temperature Setpoint Optimization
Plewe, K. E., Smith, A. D., & Liu, M. (2020) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc45564.2020.9147308 · Cited by 2
“Primarily driven by improved building simulation and control capabilities [6], MPC is becoming increasingly applicable to building control frameworks [7], [8].”
BackgroundAmiruddin, B. P., Kadir, R. E. A., & Santoso, A. (2021) · Jurnal Teknik ITS · doi:10.12962/j23373539.v10i1.59574 · Cited by 2
Building Energy Optimization with MPC Controller
Masdoua, Y., Boukhnifer, M., & Adjallah, K. H. (2021) · International Conference on System Theory, Control and Computing (ICSTCC) · doi:10.1109/icstcc52150.2021.9607246 · Cited by 2
The Temperature Control Methods for the Heat Supply System of Buildings and Structures
Tyutyunov, D., Pihtin, A., & Borodin, A. (2022) · Lecture notes in civil engineering · doi:10.1007/978-3-031-12703-8_17 · Cited by 2
Tyutyunov, D., Burtsev, A., Perepelitsa, N., & Burtsev, A. (2022) · Lecture notes in civil engineering · doi:10.1007/978-3-031-12703-8_18 · Cited by 2
Li, X., Wang, M., Wang, K., Liu, Z., & Li, G. (2023) · Optimal Control Applications and Methods · doi:10.1002/oca.2967 · Cited by 2
“(15) We consider the reference tracking and disturbance rejection of the following linear plant with an exogenous disturbance, denoted as G(s).”
BackgroundWang, M., Li, X., Wang, K., & Li, Y. (2022) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc55256.2022.10034380 · Cited by 2
“Model Predictive Control (MPC), as an advanced control strategy, has the characteristics of being applicable to nonlinear systems, explicit processing constraints, and strong robustness [12, 13], which has attracted wide attention from experts and scholars.”
BackgroundDistributed Data Center Cooling control based on Multi-Agent Reinforcement Learning
Chen, D., Wan, J., Li, L., & Liu, C. (2022) · IEEE International Conference on Frontiers Technology of Information and Computer (ICFTIC) · doi:10.1109/icftic57696.2022.10075260 · Cited by 2
“Gianluca Serale et al.[2] used the Model Predictive Control (MPC) method to manage the HVAC system of the building, which improves the energy efficiency of the building and emphasizes the advantages of MPC Method in building thermal management.”
MethodModel predictive control for smart buildings: a simulation approach within Indian context
Pandey, K., & Basu, B. (2023) · Facilities · doi:10.1108/f-11-2022-0141 · Cited by 2
ENHANCING AIR POLLUTION CONTROL WITH MACHINE LEARNING IN THE AUTOMATION FIELD
Nishat, N., Rahman, M. M., Mim, M. A., & Shoaib, A. S. M. (2024) · Academic journal on business administration, innovation & sustainability. · doi:10.69593/ajbais.v4i2.68 · Cited by 3
AI-Based MPC Controller for Energy-Efficient HVAC Systems
Al-Osta, M., Abobakr, S. A., Kaouachi, A. E., & Sboui, L. (2024) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece59415.2024.10667326 · Cited by 2
Black Box Hygrothermal Models for MPC Applications in Historical Buildings
Zehner, M., Cavaterra, A., & Lambeck, S. (2024) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit62066.2024.10708557 · Cited by 3
Online Comfort-Constrained HVAC Control via Feature Transfer
Yu, J., Zhang, T., Ardakanian, O., & Wierman, A. (2025) · ACM International Conference on Future Energy Systems (e-Energy) · doi:10.1145/3679240.3734592 · Cited by 3
Macias, E. L. M., Loor, W. D. C., Cobeña-Macías, D. A., Bermello-Moreira, N. S., & Ríos-Mera, N. P. (2025) · Revista Arquitectura + · doi:10.5377/arquitectura.v10i19.20561 · Cited by 2
Jezeh, H. O., & Moradi, H. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.128009 · Cited by 4
Göbel, S., Will, F., Stoffel, P., Vering, C., & Müller, D. (2025) · Energy Conversion and Management X · doi:10.1016/j.ecmx.2025.101306 · Cited by 2
Energy Network Modelling Approaches for Multi-Scale Building Performance Optimization
Tronchin, L., & Manfren, M. (2018) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2018.8494369 · Cited by 2
“The lack of flexibility can determine a potential additional effort for customization/adaptation of models, which may be a limiting factor for future development [8].”
BackgroundGabsi, F., Hamelin, F., Sauer, N., & Sauter, D. (2019) · Conference on Control and Fault-Tolerant Systems · doi:10.1109/systol.2019.8864733 · Cited by 3
“Model Predictive Control (MPC) is considered the most appropriate method to ensure user comfort while minimizing energy consumption [3], [4], [5].”
MethodModel Predictive Control for Virtual Inertia Synthesis
Kerdphol, T., Rahman, F. S., Watanabe, M., & Mitani, Y. (2020) · Power systems · doi:10.1007/978-3-030-57961-6_6 · Cited by 2
Thermal mode of a room with integrated regulation of cooling systems
Дмитриевич, С. О. (2021) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.34910/mce.103.12 · Cited by 2
Дмитриевич, С. О. (2021) · Safety and Reliability of Power Industry · doi:10.24223/1999-5555-2021-14-1-27-33 · Cited by 2
Data-Driven Robust MPC for Controlled Environment Agriculture
Chen, W., & You, F. (2021) · Computer-aided chemical engineering/Computer aided chemical engineering · doi:10.1016/b978-0-323-88506-5.50182-0 · Cited by 3
Solar Radiation Forecasting for Smart Building Applications
Notton, G., Faggianelli, G. A., Voyant, C., Ouédraogo, S., Pigelet, G., & Duchaud, J.-L. (2022) · Green energy and technology · doi:10.1007/978-3-030-96429-0_11 · Cited by 4
Model Predictive Control for Building Automation
Bolt, P., Jaeger, C., Zierbart, V., Ritzmann, R., Maier, O., & Füchslin, R. M. (2018) · EuroSun Conference · doi:10.18086/eurosun2018.11.05 · Cited by 2
Control Solutions for TES Applications
de Gracia, Á., Crespo, A., Vérez, D., Tarragona, J., & Cabeza, L. F. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-819723-3.00028-7 · Cited by 2
Koch, M., & Jones, C. N. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2302.04063 · Cited by 2
Mit Automatisierung gegen den Klimawandel
(2023) · doi:10.33968/2023.01 · Cited by 2
Coccia, G., Mugnini, A., Polonara, F., & Arteconi, A. (2020) · TECNICA ITALIANA-Italian Journal of Engineering Science · doi:10.18280/ti-ijes.642-412 · Cited by 1
Simulation-based assessment on stochastic load scheduling for building cooling systems
Huang, S., Huang, B., Katipamula, S., & Ma, X. (2022) · Science and Technology for the Built Environment · doi:10.1080/23744731.2022.2151271 · Cited by 1
“Based on a survey (Serale et al. 2018), the value of the prediction horizon is usually selected to be larger than 1 hour and less than 1 day while the control interval is usually selected from a range of 5 to 60min.”
BackgroundSupervisory optimal control using machine learning for building thermal comfort
Abdufattokhov, S., Mahamatov, N., Ibragimova, K., Gulyamova, D., & Yuldashev, D. (2022) · Badania Operacyjne i Decyzje/Operations Research and Decisions · doi:10.37190/ord220401 · Cited by 2
Development of gas turbine model interface for digital twin application
Sundararajan, A., Omar, M., Ibrahim, R., & Salehuddin, N. F. (2024) · AIP conference proceedings · doi:10.1063/5.0195494 · Cited by 1
Ganavi, P., & Jayasankar, V. N. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-4650-7_14 · Cited by 1
Data-Driven Domestic Flexible Demand: Observations from Experiments in Cold Climate
Reinhardt, D., Cai, W., & Gros, S. (2025) · Green energy and technology · doi:10.1007/978-3-031-69015-0_25 · Cited by 3
Impact of Wind Speed Look-Ahead Mismatch on Carbon Dioxide-based IAQ Nonlinear MPC
Pepe, C., Ali, M. F., & Zanoli, S. M. (2025) · International Carpathian Control Conference · doi:10.1109/iccc65605.2025.11022933 · Cited by 1
“In this field, modelling, optimization, control, monitoring and maintenance solutions are covering a key role; for example, Advanced Process Control (APC) and Model Predictive Control (MPC) techniques can be applied in order to find optimal trade-offs between different specifications [3], [4].”
Klanatsky, P., Veynandt, F., & Heschl, C. (2025) · MethodsX · doi:10.1016/j.mex.2025.103470 · Cited by 1
Robust co-design framework for buildings operated by predictive control
Falugi, P., O’Dwyer, E., Zagórowska, M., Kerrigan, E. C., Nie, Y., Štrbac, G., & Shah, N. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116144 · Cited by 1
Power-constrained VRF system optimization using symbolic regression for multiple zones environment
Thu, T. T., Kato, K., Zhao, D., Nishikawa, H., Taniguchi, I., & Onoye, T. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116264 · Cited by 2
He, N., Cheng, Z., Cheng, Q., Cai, C., & Li, R. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.113837 · Cited by 3
Alsaadi, F. E., Alharbi, N. S., & Al-Barakati, A. A. (2025) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2025.117590 · Cited by 1
Partovi, A., Farhadi, A., & Sharifzadeh, M. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3635390 · Cited by 1
Hasan, M. M., Dharmasena, P., & Nassif, N. (2025) · Energies · doi:10.3390/en19010082 · Cited by 1
Tang, L.-X., & Wang, M. (2026) · Symmetry · doi:10.3390/sym18030398 · Cited by 1
“The objective function is defined as [31]: where J denotes the objective function value, N p is the prediction horizon length, N c is the control horizon length, P cool ( k ) represents the cooling system power at step k (kW), T ( k ) denotes the predicted temperature vector at step k , T ref is…”
InfluentialMonghasemi, N., Vadiee, A., Vouros, S., & Kyprianidis, K. (2026) · Energy Informatics · doi:10.1186/s42162-026-00650-9 · Cited by 2
Hybrid Model Predictive Control for the regulation of carbon dioxide in plant growth chambers
Cimini, G., Pannico, A., Gatti, M., Bernardini, D., & Pascale, S. D. (2026) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2026.111650 · Cited by 1
Self-citationYevsieiev, V., & Голод, І. (2026) · Open Information and Computer Integrated Technologies · doi:10.32620/oikit.2026.107.07 · Cited by 1
Zhang, S., Lei, X., Shan, X., Li, T., & Wu, W. (2026) · Buildings · doi:10.3390/buildings16061269 · Cited by 1
Frahat, N. B., Abdelhady, M. I., Mohamed, E. N., & Ibrahim, O. M. O. (2026) · Journal of Architectural Engineering · doi:10.1061/jaeied.aeeng-2214 · Cited by 1
Phyu, N. S., Jiren, M., Yousif, M. Z., Kim, H., Song, J., & Lim, H.-C. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.107984 · Cited by 1
Sotubo, A. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1014198 · Cited by 1
Tsai, Y.-K., & Malak, R. (2026) · Journal of Mechanical Design · doi:10.1115/1.4071654 · Cited by 1
AI-driven climate-resilient HVAC control: A scalable framework for grid-Interactive buildings
Alhamami, A. H., Humaidan, O. A., Alshayeb, M. J., Almazam, K. A., & Dodo, Y. A. (2026) · Energy · doi:10.1016/j.energy.2026.141618 · Cited by 1
Zhao, B., Gammulle, H., Fernando, T., Fookes, C., & Morawska, L. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114917 · Cited by 1
A virtual reality study on the influence of indoor visual quality on thermal comfort perception
Bernagozzi, M., Siagkri, R., & Picco, M. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115372 · Cited by 1
Huang, C., Jia, X., Seidel, S., Paschke, F., & Bräunig, J. (2021) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa45728.2021.9613280 · Cited by 1
Model Predictive Control of Building Energy System including Thermal Energy Storage
Lee, D., Ooka, R., Ikeda, S., Choi, W., & Kwak, Y. (2020) · Building Simulation Conference proceedings · doi:10.26868/25222708.2019.210664 · Cited by 2
“In a previous publication (Serale et al., 2018), the authors stated that one of the advantages of MPC strategy is that it can consider future disturbances on the basis of its predictive nature and optimization process.”
BackgroundFEATURES OF THE USE OF MODEL-PREDICTIVE CONTROL IN BUILDING AUTOMATION
Захарченко, А. С., & Степанець, О. В. (2020) · Scientific notes of Taurida National V I Vernadsky University Series Technical Sciences · doi:10.32838/tnu-2663-5941/2020.6-1/12 · Cited by 1
Lorenzi, A. D., Gambarotta, A., Morini, M., & Saletti, C. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202123805001 · Cited by 1
Comfort Cognitive IoT for Efficient Monitoring and Predictive in Building Management Systems
Vinnarasi, A. P., & Sangeetha, M. (2021) · International Conference on Wireless Communications, Signal Processing and Networking (WiSPNET) · doi:10.1109/wispnet51692.2021.9419408 · Cited by 1
Дмитриевич, С. О. (2021) · Vestnik MGSU · doi:10.22227/1997-0935.2021.4.486-492 · Cited by 1
An IOT Based Building Occupancy Estimation Using SIMCA and KNN as Classification Models
Gupta, D., Biswas, S., Pramanik, A., Chatterjee, A., & Venkateswaran, P. (2021) · Lecture notes in networks and systems · doi:10.1007/978-981-16-4435-1_54 · Cited by 1
Metadata
- Authors
- Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A.
- Affiliations
- Politecnico di Torino (IT)
- University of Wollongong (AU)
- ODYS S.r.l., Via Pastrengo, 14, 20159 Milano, Italy
- IMT School for Advanced Studies Lucca (IT)
- Corresponding author
- Serale, Gianluca
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2018-03-12
- Volume
- 11
- Issue
- 3
- Pages
- 631
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2789880759
- Cited by
- 637
- References
- 178
- Citations by year
- 2026: 84 · 2025: 93 · 2024: 70 · 2023: 96 · 2022: 85 · 2021: 100 · 2020: 61 · 2019: 38 · 2018: 10
- FWCI
- 41.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- PORTO@Iris (submittedVersion, cc-by)
- Research Online (University of Wollongong) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion)
- Funders
- Politecnico di Torino
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Keywords
- model predictive control, building energy efficiency, HVAC systems, building thermal management, building thermal mass, indoor thermal comfort, building energy demand, building automation, disturbance prediction, multi-objective optimization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.