Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review
Open accessThe DOI matches its Crossref record; 306 of the 315 references it cites were found in a registry or an index.
Abstract
Power systems are the most complex systems that have been created by men in history. To operate such systems in a stable mode, several control loops are needed. Voltage frequency plays a vital role in power systems which need to be properly controlled. To this end, primary and secondary frequency control loops are used to control the frequency of the voltage in power systems. Secondary frequency control, which is called Load Frequency Control (LFC), is responsible for maintaining the frequency in a desirable level after a disturbance. Likewise, the power exchanges between different control areas are controlled by LFC approaches. In recent decades, many control approaches have been suggested for LFC in power systems. This paper presents a comprehensive literature survey on the topic of LFC. In this survey, the used LFC models for diverse configurations of power systems are firstly investigated and classified for both conventional and future smart power systems. Furthermore, the proposed control strategies for LFC are studied and categorized into different control groups. The paper concludes with highlighting the research gaps and presenting some new research directions in the field of LFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 Comparison between different objective functions, i.e., IAE, ISE, ITAE, and ITSE: ( a ) frequency deviations in different control areas; ( b ) frequency overshoot; and ( c ) frequency settling time. IAE: Integral of absolute error; ISE: integral of squared error; ITAE: integral of time multiplied by absolute error; ITSE: integral of time multiplied by squared error [295].](https://figures.cochat.ai/paper-figures/5088e2370d0d492690748566492ddd25/challenges-and-opportunities-of-load-frequency-control-in-conventional-modern-figure-4.png)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A power system's operational point may eventually experience variations from the nominal system frequency and planned power exchanges to other places, which could have a negative impact [75].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
The cited source says what the claim attributes to it.
In the citing paper
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–306 of 306
AGC of a multi area gas-thermal system using firefly optimized IDF controller
Saikia, L. C., Chowdhury, A., Shakya, N., Shukla, S., & Soni, P. K. (2013) · IEEE India Conference · doi:10.1109/indcon.2013.6725998 · Cited by 36 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundOptimal control of interconnected, electric energy systems—A new formulation
Tacker, E. C., Lee, C. C., Reddoch, T. W., Tan, T.-S., & Julich, P. M. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8887 · Cited by 35
Hasan, N., Ibraheem, Kumar, P., & Nizamuddin (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.039 · Cited by 35 · cited 1×
“Suboptimal and near-optimal controls are presented in [201] and a suboptimal AGC regulator scheme for a two-area interconnected system in [205,206].”
BackgroundIbraheem, Kumar, P., Hasan, N., & Nizamuddin (2012) · Electric Power Components and Systems · doi:10.1080/15325008.2012.675802 · Cited by 35 · cited 1×
“Suboptimal and near-optimal controls are presented in [201] and a suboptimal AGC regulator scheme for a two-area interconnected system in [205,206].”
BackgroundVerma, Y. P., & Kumar, A. (2012) · Frontiers in Energy · doi:10.1007/s11708-012-0218-6 · Cited by 34 · cited 2×
“LFC scheme for hydro–hydro interconnected power systems considering the hydro power plants non-linearities is proposed in [38,44,45].”
BackgroundVerma, R., Pal, S., & Sathans, S. (2013) · International Conference on Communication Systems and Network Technologies · doi:10.1109/csnt.2013.119 · Cited by 33 · cited 2×
“LFC scheme for hydro–hydro interconnected power systems considering the hydro power plants non-linearities is proposed in [38,44,45].”
BackgroundMethodLiaw, C. M. (1994) · International Journal of Control · doi:10.1080/00207179408921510 · Cited by 33 · cited 1×
“A reduced order adaptive controller for LFC is suggested in [212] and a multi-area adaptive load frequency control strategy is developed in [211].”
MethodDamping effects of excitation control in load-frequency control system
Moorthi, V. R., & Aggarwal, R. P. (1974) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1974.0293 · Cited by 33 · cited 2×
“A more realistic LFC model is developed in [24] under different load conditions by considering the excitation system for voltage regulation and optimal responses.”
MethodSequential design of decentralized load frequency controllers using μ synthesis and analysis
Bevrani, H., Mitani, Y., & Tsuji, K. (2003) · Energy Conversion and Management · doi:10.1016/s0196-8904(03)00196-1 · Cited by 33 · cited 1×
“A design guideline of a decentralized robust LFC method is described in [238] based on u-synthesis in multi-area power systems where the information about the controllers design in the previous step is considered in the synthesis procedure, at each step.”
MethodBhatt, P. J., Ghoshal, S. P., Roy, R., & Ghosal, S. (2010) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2010.5712524 · Cited by 33 · cited 1×
“In [272,273], LFC problem in single-area power systems is solved by PSO.”
BackgroundSimulation of two-area AGC system in a competitive environment using reduced-order observer method
Rakhshani, E., & Sadeh, J. (2008) · doi:10.1109/eem.2008.4579082 · Cited by 32
Automatic generation control for hydro systems
Kusic, G. L., Sutterfield, J. A., Caprez, A. R., Haneline, J. L., & Bergman, B. R. (1988) · IEEE Transactions on Energy Conversion · doi:10.1109/60.4196 · Cited by 32 · cited 1×
“A mathematical dynamic model of frequency response for single-area power systems is discussed in [8,15,16].”
BackgroundLfc Design Of A Deregulated Power System With Tcps Using Pso
Shayeghi, H., Shayanfar, H. A., & Jalili, A. (2009) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1062781 · Cited by 31
Jagatheesan, K., Anand, B., Dey, N., & Amira, S. (2015) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2015.060727 · Cited by 31
Fault Detection and Isolation in Power Systems Using Unknown Input Observer
Alhelou, H. H. (2018) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-6989-3.ch002 · Cited by 31
Self-citationMulti-area load frequency control in a power system using optimal output feedback method
Parmar, K. P. S., Majhi, S., & Kothari, D. P. (2010) · doi:10.1109/pedes.2010.5712487 · Cited by 30
Suboptimal and near-optimal control of a load-frequency-control system
Moorthi, V. R., & Aggarwal, R. P. (1972) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1972.0329 · Cited by 30
Interaction modelling approach to distributed control with application to power systems
Aldeen, M. (1991) · International Journal of Control · doi:10.1080/00207179108953664 · Cited by 28
Design of decentralised load-frequency regulators for interconnected power systems
Hiyama, T. (1982) · IEE Proceedings C Generation Transmission and Distribution · doi:10.1049/ip-c.1982.0003 · Cited by 28
Prakash, S., Bhardwaj, A. K., & Sinha, S. K. (2012) · International Conference on Power, Control and Embedded Systems · doi:10.1109/icpces.2012.6508124 · Cited by 27 · cited 1×
“The uncertainties of power system parameters are taken into account by using a fuzzy control for a LFC model in [75].”
MethodChen, C., Zhang, K., Yuan, K., & Teng, X. (2017) · Energies · doi:10.3390/en10010078 · Cited by 27 · cited 1×
“Two-area power system frequency response models consisting of reheat-thermal turbines connected by AC/DC links are presented in [35,42,43].”
BackgroundDESIGN OF DECENTRALIZED ROBUST LFC IN A COMPETITIVE ELECTRICITY ENVIRONMENT
Shayeghi, H., & Shayanfar, H. A. (2005) · Cited by 26
Decentralised proportional-plus-integral design method for interconnected power systems
Aldeen, M., & Marsh, J. F. (1991) · IEE Proceedings C Generation Transmission and Distribution · doi:10.1049/ip-c.1991.0033 · Cited by 26 · cited 3×
“A decentralized controller for the load frequency control problem is presented in [70,241,242,246,253] using tunable”
MethodRobust controller design for automatic generation control based on Q-parameterization
Azzam, M., & Mohamed, Y. S. (2002) · Energy Conversion and Management · doi:10.1016/s0196-8904(01)00118-2 · Cited by 25 · cited 1×
“The Q-parameterization theory is used to design a robust controller to control the frequency deviations in [231] which led to a stable control.”
MethodKumari, N., & Jha, A. N. (2013) · UKSim International Conference on Computer Modelling and Simulation (UKSim) · doi:10.1109/uksim.2013.38 · Cited by 25
Load Frequency Control via Constant Limited-State Feedback
Choi, S. S., Sim, H. K., & Tan, K. (1981) · Electric Power Systems Research · doi:10.1016/0378-7796(81)90003-1 · Cited by 25
An Assessment of Load Frequency Control Impacts Caused by Small Wind Turbines
Curtice, D., & Reddoch, T. W. (1983) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1983.318012 · Cited by 25
Prakash, S., & Sinha, S. K. (2012) · Students Conference on Engineering and Systems · doi:10.1109/sces.2012.6199090 · Cited by 25
Thirunavukarasu, R., & Chidambaram, I. A. (2015) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.08.001 · Cited by 24 · cited 1×
“Authors in [183] presented the performances of different classical control approaches, e.”
BackgroundYamashita, K., & Miyagi, H. (1989) · International Journal of Control · doi:10.1080/00207178908559725 · Cited by 24
A Nonlinear Load-Frequency Control Design
Doraiswami, R. (1978) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1978.354611 · Cited by 23 · cited 1×
“An observer for nonlinear systems is also presented in [200].”
BackgroundControl of DFIG-based wind farms for power network frequency support
Zhang, X., Li, H., & Wang, Y. (2010) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2010.5666673 · Cited by 23
Rubaai, A., & Udo, V. E. (1992) · Electric Power Systems Research · doi:10.1016/0378-7796(92)90003-j · Cited by 23
A ROBUST DECENTRALIZED POWER SYSTEM LOAD FREQUENCY CONTROL
Shayeghi, H. (2008) · Cited by 23
AGC System after Deregulation Considering TCPS in Series with the Tie-Line
Abraham, R. J., Das, D., & Patra, A. (2015) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2013-0165 · Cited by 22 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Pati, T. K., Nayak, J. R., & Sahu, B. K. (2015) · IEEE International Conference on Signal Processing, Informatics, Communication and Energy Systems (SPICES) · doi:10.1109/spices.2015.7091560 · Cited by 21 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundFuzzy Logic Control Optimal Realization Using GA for Multi-Area AGC Systems
Du, X., & Li, P. (2008) · Cited by 21
Power-system model for large frequency disturbances
Ashmole, P., Battlebury, D. R., & Bowdler, R. K. (1974) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1974.0141 · Cited by 20 · cited 1×
“A mathematical dynamic model of frequency response for single-area power systems is discussed in [8,15,16].”
BackgroundObservability, controllability and decentralized control of interconnected power systems
Aldeen, M., & Marsh, J. F. (1990) · Computers & Electrical Engineering · doi:10.1016/0045-7906(90)90013-6 · Cited by 20 · cited 1×
“A decentralized controller for the load frequency control problem is presented in [70,241,242,246,253] using tunable”
MethodIntelligent automatic generation control: Multi-agent Bayesian networks approach
Bevrani, H., Daneshfar, F., & Daneshmand, P. R. (2010) · IEEE International Symposium on Intelligent Control · doi:10.1109/isic.2010.5612931 · Cited by 20
Suman, M., Rao, M. V. G., Ganugula, R. S. N. K., & Sekhar, O. C. (2014) · International Conference on Advances in Electrical Engineering · doi:10.1109/icaee.2014.6838530 · Cited by 19
Load frequency control using Lyapunov's second method: Bang-bang control of speed changer position
Shirai, G. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11491 · Cited by 19 · cited 1×
“Lyapunov’s second scheme applying minimum setting time theory is also introduced in [207] for AGC regulator design.”
MethodDecentralized load frequency based on H∞ control
Ishii, T., Shirai, G., & Fujita, G. (2001) · Electrical Engineering in Japan · doi:10.1002/eej.1062 · Cited by 19 · cited 1×
“A decentralized load frequency controller is proposed in [237] based on the optimal control which incorporated an observer.”
BackgroundFitri, I. R., Kim, J., & Song, H. (2017) · Energies · doi:10.3390/en10050595 · Cited by 19 · cited 1×
“A robust control scheme is proposed in [224,225] based on the Riccati equation for a single area thermal power system.”
MethodEffect of Power Plant Response on Optimum Load Frequency Control System Design
Barcelo, W. R. (1973) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1973.293621 · Cited by 18 · cited 1×
“A plant response time is designed using linear optimal control theory and its effect on the closed loop poles is investigated in [198].”
A variable structure-based controller with fuzzy tuning for load-frequency control
Ha, Q. P., & Trinh, H. M. (2000) · ResearchOnline - JCU (James Cook University) · Cited by 18
A Novel Neuro-Optimal Approach for Decentralized LFC Design in Multi-Area Power System
Ansarian, M., Hamed Shakouri, G., Nazarzadeh, J., & Sadeghzadeh, S. M. (2006) · IEEE International Conference on Power and Energy · doi:10.1109/pecon.2006.346640 · Cited by 18
Aggarwal, R., & Bergseth, F. R. (1968) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1968.292049 · Cited by 17 · cited 1×
“HVDC transmission links between the different control areas in four-area interconnected power system are considered in [82,87], while DC transmission links are used to tie the different control area in five-area power system in [87].”
MethodOptimal distribution of load-frequency control signal to hydro power plants
Vrdoljak, K., Perić, N., & Sepac, D. (2010) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2010.5637553 · Cited by 17 · cited 1×
“In order to regulate the frequency and tie-line power flow using communication links, decentralized proportional-integral control [162], dual mode proportional–integral (PI) controller [157] and PI control for hydropower system [158] have been proposed.”
BackgroundDavison, E. J., & Tripathi, N. (1979) · IEEE Conference on Decision and Control including the Symposium on Adaptive Processes (CDC) · doi:10.1109/cdc.1979.270073 · Cited by 17 · cited 2×
“A decentralized controller for the load frequency control problem is presented in [70,241,242,246,253] using tunable”
BackgroundMethodJagatheesan, K., & Anand, B. (2014) · IEEE International Conference on Computational Intelligence and Computing Research (ICCIC) · doi:10.1109/iccic.2014.7238280 · Cited by 17
Frequency control of multi-area power system network using PSO based LQR
Kumari, N., & Jha, A. N. (2014) · IEEE Power India International Conference · doi:10.1109/34084poweri.2014.7117761 · Cited by 17 · cited 1×
“Likewise, LFC problem in interconnected power systems with multiple sources such as thermal, hydro, and gas turbines has been handled by PSO in [274].”
BackgroundReview of Load Frequency Control methods, Part-I: Introduction and Pre-deregulation Scenario
Jain, S. K., Chakrabarti, S., & Singh, S. N. (2013) · doi:10.1109/care.2013.6733736 · Cited by 17
Hydrogenerator system identification using a simple genetic algorithm
Wrate, C. A., & Wozniak, L. (1997) · IEEE Transactions on Energy Conversion · doi:10.1109/60.577281 · Cited by 16 · cited 1×
“In [110], GA has been also suggested for AGC in hydro–thermal power systems.”
BackgroundGenetic fuzzy PID controller based on adaptive gain scheduling for load frequency control
Kumar, A., Kumar, A., & Chanana, S. (2010) · doi:10.1109/pedes.2010.5712377 · Cited by 16
Kouba, N. E. Y., Menaa, M., Hasni, M., & Boudour, M. (2015) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2015.7233025 · Cited by 15
A decentralized scheme of load frequency control of power system
Kawabata, H., & Kido, M. (1982) · Electrical Engineering in Japan · doi:10.1002/ecja.4391020414 · Cited by 15
Kamboj, V. K., Arora, K., & Khurana, P. (2012) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v2i4.305 · Cited by 15 · cited 1×
“The LFC models of multi-source two-area power system considering nonlinearities are marked out in [37].”
BackgroundRay, P. K., Mohanty, S. R., Kishor, N., & Mohanty, A. (2009) · doi:10.1109/icetet.2009.203 · Cited by 15 · cited 1×
“Frequency response models suitable for power systems with high penetration of renewable energy sources are suggested in [112,113,122].”
BackgroundSmart Automatic Generation Control
Chen, D., Kumar, S., York, M., & Wang, L. (2012) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2012.6345136 · Cited by 15
Combined modal and singular perturbation approach to decentralized control
Aldeen, M., & Trinh, H. M. (1992) · International Journal of Systems Science · doi:10.1080/00207729208949246 · Cited by 14 · cited 1×
“To realize the decoupling of the interconnection into its subsystem components, model and singular perturbation techniques are employed [204].”
MethodStudy of the Effect of the DC Link on Frequency Control in Interconnected AC Systems
Yoshida, Y., & Machida, T. (1969) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1969.292503 · Cited by 14
Automatic Generation Control of Multi Area Power Plants with the Help of Advanced Controller
Gondaliya, S., & Arora, K. (2015) · International Journal of Engineering Research and · doi:10.17577/ijertv4is040671 · Cited by 14
AGC of a multi-area interconnected system with FACTS and firefly optimized 2DOF PID controller
Dash, P., Saikia, L. C., & Sinha, N. (2014) · doi:10.1109/ciec.2014.6959118 · Cited by 14 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundAutomatic generation control of multi-area hydro system using classical controllers
Saikia, L. C., Bharali, A., Dixit, O., Malakar, T., Sharma, B., & Kouli, S. (2012) · International Conference on Power and Energy in NERIST (ICPEN) · doi:10.1109/icpen.2012.6492329 · Cited by 14 · cited 12×
“Keywords: automatic generation control (AGC); frequency deviation; interconnected power systems; load frequency control (LFC); supplementary frequency control; secondary frequency control; smart grids; tie-lines power deviation”
ResultInfluentialBayesian networks design of load-frequency control based on GA
Daneshfar, F., Bevrani, H., & Mansoori, F. N. A. (2011) · International Conference on Control, Instrumentation, and Automation · doi:10.1109/icciautom.2011.6356676 · Cited by 13 · cited 1×
“Unified PID tuning method [81] and optimal Multiple Input–Multiple output (MIMO-PID) control is used for LFC [167].”
MethodRegression model for tuning the PID controller with fractional order time delay system
Agnihotri, S. P., & Waghmare, L. M. (2014) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2014.04.007 · Cited by 13
PID controller adjustment for MA-LFC by using Imperialist Competitive Algorithm
Soheilirad, M., Farzan, P., Othman, M. L., Karami, K., & Hojabri, M. (2013) · IEEE International Power Engineering and Optimization Conference · doi:10.1109/peoco.2013.6564601 · Cited by 13
Ghatuari, I., Mishra, N. K., & Sahu, B. K. (2013) · International Conference on Energy Efficient Technologies for Sustainability · doi:10.1109/iceets.2013.6533568 · Cited by 13
NARMA-L2 controller for three-area load frequency control
Adaryani, M. R., & Afrakhte, H. (2011) · Iranian Conference on Electrical Engineering · Cited by 12
Coordinated Frequency and Voltage Control of Synchronous Generators
Hsu, Y., & Chan, W.-C. (1987) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1987.313352 · Cited by 12 · cited 2×
“In [22,23,30,31], load frequency control schemes for thermal–thermal two-area power system taking into account the delay in communication channels are proposed.”
BackgroundMinimum variance strategy for load-frequency control
Sheirah, M. A., Malik, O. P., & Hope, G. S. (1986) · International Journal of Electrical Power & Energy Systems · doi:10.1016/0142-0615(86)90006-2 · Cited by 12
Bensenouci, A., & Ghany, A. M. A. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4374619 · Cited by 12 · cited 1×
“Authors in [184,185] proposed a control method for LFC in power systems by using a variable structure control scheme.”
MethodMulti — Area AGC with AC/DC link and BES and Cuckoo Search optimized PID controller
Saikia, L. C., Das, S. K., Dash, P., & Raju, M. (2015) · International Conference on Computer, Communication, Control and Information Technology · doi:10.1109/c3it.2015.7060203 · Cited by 12
ANFIS based Neuro-Fuzzy Controller in LFC of Wind-Micro Hydro-Diesel Hybrid Power System
Dhanalakshmi, R., & Palaniswami, S. (2012) · International Journal of Computer Applications · doi:10.5120/5698-7745 · Cited by 12
Debbarma, S., Saikia, L. C., & Sinha, N. (2013) · IEEE PES Asia-Pacific Power and Energy Engineering Conference · doi:10.1109/appeec.2013.6837223 · Cited by 11
Zhao, H. C., Zhu, G., & Xu, C. (2012) · China International Conference on Electricity Distribution (CICED) · doi:10.1109/ciced.2012.6508526 · Cited by 10 · cited 1×
“PI control for micro source systems is presented in [156].”
BackgroundStep response of a governed hydrogenerator
Foord, T. R. (1978) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1978.0264 · Cited by 10 · cited 1×
“A mathematical dynamic model of frequency response for single-area power systems is discussed in [8,15,16].”
Background3-level load-frequency control of power systems interconnected by asynchronous tie lines
Bengiamin, N. N., & Chan, W. C. (1979) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1979.0205 · Cited by 10
Panda, S., Swain, S. C., & Mahapatra, S. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.11.026 · Cited by 10 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundPérez‐Díaz, J. I., & Sarasúa, J. I. (2015) · Energies · doi:10.3390/en81010584 · Cited by 10
Jagatheesan, K., Anand, B., & Dey, N. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-81-322-2757-1_20 · Cited by 10
An Analysis of Two Area Load Frequency Control with Different Types of Feedback Controllers
Hore, D. (2014) · Cited by 9
Aggregation of plug-in electric vehicles in distribution networks for primary frequency control
Izadkhast, S., García-González, P., Frías, P., Ramirez-Elizondo, L. M., & Bauer, P. (2014) · IEEE International Electric Vehicle Conference · doi:10.1109/ievc.2014.7056225 · Cited by 9 · cited 1×
“A new frequency response model of plug-in EVs is proposed for primary and secondary frequency control levels in [150].”
BackgroundLoad frequency control using a governor and voltage controls vis a new approach
Shirai, G. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.11132 · Cited by 9 · cited 1×
“A new decentralized load frequency control scheme is proposed in [254] by using the governor and voltage controls via a new approach based on Siljak’s theory for two-area thermal power systems.”
MethodVillena, J., Vigueras‐Rodríguez, A., Gómez‐Lázaro, E., Fuentes, J. A., Muñoz‐Benavente, I., & Molina‐García, Á. (2015) · Energies · doi:10.3390/en81112349 · Cited by 9 · cited 1×
“Dynamic demand response which is considered as a key feature of smart grids has been developed for LFC in [138,139,149].”
BackgroundRezvantalab, J., Kazemi, M. H., & Seddigh, A. K. (2009) · Cited by 9
Load frequency control in Microgrid
Singh, A. K. N. H. H. P., singh, C., & Yadav, N. K. (2013) · Cited by 8
Intelligent adaptive turbine controller
Jovanović, S., Hogg, B. W., & Fox, B. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.372587 · Cited by 8 · cited 2×
“To improve the performance of power system frequency controllers, a self-tuning steam turbine control strategy proposed in [111].”
BackgroundMethodMuñoz‐Benavente, I., Gómez‐Lázaro, E., García-Sánchez, T. M., Vigueras‐Rodríguez, A., & Molina‐García, Á. (2017) · Energies · doi:10.3390/en10020151 · Cited by 8
Particle swarm optimization sliding mode control on interconnected power system
Guo, X., & Liu, X. (2014) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2014.6896602 · Cited by 7
Fuzzy gain scheduled automatic generation control of two area multi unit power system
Verma, R., Pal, S., & Sathans (2013) · Students Conference on Engineering and Systems · doi:10.1109/sces.2013.6547558 · Cited by 7 · cited 1×
“LFC scheme for hydro–hydro interconnected power systems considering the hydro power plants non-linearities is proposed in [38,44,45].”
BackgroundDutta, A., & Debbarma, S. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352345 · Cited by 7 · cited 1×
“Reference [49] proposes LFC model of conventional two-area power systems combined with the participation of electric vehicles and energy storage systems.”
BackgroundKumar, T. A., & Ramana, N. V. (2015) · International Conference on Electrical, Electronics, Signals, Communication and Optimization · doi:10.1109/eesco.2015.7253883 · Cited by 5 · cited 1×
“Integral of absolute error (IAE) [162,318], integral of time multiplied by absolute error (ITAE) [319], integral of squared error (ISE) [102,320] and integral of time multiplied by squared error (ITSE) [170,295,321] are the most important criteria used for designing load frequency controllers.”
MethodIntelligent Decentralized Controllers for Multi Area Power Systems
Yadaiah, N., & Srinivas, P. S. (2006) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2006.257206 · Cited by 5
Load frequency sampled-data control via Lyapunov's second method
Shirai, G. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.11932 · Cited by 5
Zhou, H. L., Hao, Y., & Tan, W. (2014) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2014.7053508 · Cited by 5
Decentralized sliding mode stabilizer design for multi-area interconnected power systems
Yang, M.-S. (2002) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2000.930509 · Cited by 5
Kazemi, A., & Andami, H. (2004) · Cited by 5
Pandey, S. K., Mohanty, S. R., Kishor, N., & Payasi, R. P. (2013) · International Conference on Power, Energy and Control · doi:10.1109/icpec.2013.6527695 · Cited by 4
AGC of an interconnected multi-area hydrothermal system using a neuro-fuzzy controller
Saikia, L. C., Paul, A. T., Dash, P., & Choudhury, N. B. D. (2014) · International Conference on Control, Instrumentation, Energy & Communication · doi:10.1109/ciec.2014.6959120 · Cited by 4
A decentralized reliable automatic generation control
Mahmoud, M. S., & Ismail, A. (2009) · International Conference on Electric Power and Energy Conversion Systems · Cited by 4
Mola, S. M., & Jahed‐Motlagh, M. R. (2014) · International Conference on Intelligent Control and Information Processing · doi:10.1109/icicip.2014.7010323 · Cited by 3
Ganapathy, S., & Velusami, S. (2010) · International Journal of Computer Applications · doi:10.5120/186-322 · Cited by 3
A robust adaptive predictive load frequency controller to compensate for model mismatch
Siraj, S. F., Muin, M. Z. A., Nor, K. M., Rahim, S. R. A., Mohamad, M. F., & Mid, E. C. (2010) · IEEE International Power Engineering and Optimization Conference · doi:10.1109/peoco.2010.5559181 · Cited by 3 · cited 1×
“Some other issues of a hydro–thermal systems are described in [213,219,220].”
BackgroundKumar, P., Varshana, P., & Das, J. K. (2002) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.1998.797114 · Cited by 3 · cited 2×
“Discussion on the reduction of the frequency response model order to reduce its complexity is presented in [25,39,41].”
BackgroundMethod
Research works printed but not linked: 14
- Concordia, 1953, Tie-line power and frequency control of electric power systems, Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst., 72, 562
- Concordia, 1954, Tie-line power and frequency control of electric power systems-Part II, Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst., 73, 133
- Chokpanyasuwan, C. (2008, January 12–14). Robot Fuzzy logic-PID Controller for Wind-Diesel Power System using Particle Swarm Optimization. Proceedings of the GMSARN International Conference on Sustainable Development: Issues and Prospects for the GMS, Kunming, China.
- Hilloowala, R.M., and Sharaf, A.M. (1993, January 2–8). A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme. Proceedings of the Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting, Toronto, ON, Canada.
- Lasseter, R.H. (2002, January 27–31). Microgrids. Proceedings of the Power Engineering Society Winter Meeting, New York, NY, USA.
- Lakshmi, 2014, Pso based load frequency control for single area power system, Int. J. Sci. Eng. Res., 5, 12
- Velusami, 1997, Design of observer-based decentralized load-frequency controllers for interconnected power systems, Int. J. Power Energy Syst., 17, 152
- Feliachi, 1987, Load frequency control using reduced order models and local observers, Int. J. Energy Syst., 7, 72
- Rao, C.S. (2012, January 30–31). Adaptive Neuro Fuzzy based Load Frequency Control of multi area system under open market scenario. Proceedings of the 2012 International Conference on Advances in Engineering, Science and Management (ICAESM), Nagapattinam, India.
- Karrari, 1999, Design of H∞ controller load frequency control in electrical power systems, Amirkabir J. Sci. Technol., 11, 79
- Bevrani, H. (1999, January 22–27). Robust load frequency controller in a deregulated environment: A/spl mu/-synthesis approach. Proceedings of the 1999 IEEE International Conference on Control Applications, Kohala Coast, HI, USA.
- Bensenouci, A., and Ghany, A.A. (2007, January 9–12). Mixed H∞/H2 with pole-placement design of robust LMI-based output feedback controllers for multi-area load frequency control. Proceedings of the International Conference on “Computer as a Tool” (EUROCON 2007), Warsaw, Poland.
- Chidambaram, 2009, Genetic algorithm based decentralized controller for load-frequency control of interconnected power systems with RFB considering TCPS in the tie-line, Int. J. Electron. Eng. Res., 1, 299
- Balasundaram, 2012, ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB, Int. J. Eng. Innov. Technol., 1, 1
Cited by
A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges
Haes Alhelou, H., Hamedani-Golshan, M. E., Njenda, T. C., & Siano, P. (2019) · Energies · doi:10.3390/en12040682 · Cited by 643
“The ability of power systems to maintain stability and to ensure continuous supply of electrical power to customers in the event of a disturbance is of critical importance [5,14].”
BackgroundSelf-citationEnergy systems for climate change mitigation: A systematic review
Kang, J.-N., Wei, Y.-M., Liu, L.-C., Han, R., Yu, B.-Y., & Wang, J.-W. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114602 · Cited by 276
Alhamrouni, I., Abdul Kahar, N. H., Salem, M., Swadi, M., Zahroui, Y., Kadhim, D. J., Mohamed, F. A., & Alhuyi Nazari, M. (2024) · Applied Sciences · doi:10.3390/app14146214 · Cited by 217
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
BackgroundJi, W., Hong, F., Zhao, Y., Lu, L., Du, H., Hao, J., Fang, F., & Liu, J. (2024) · Renewable Energy · doi:10.1016/j.renene.2024.119975 · Cited by 176
Alhelou, H. H., Golshan, M. E. H., & Hatziargyriou, N. D. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2916558 · Cited by 151
“For interested readers, comprehensive surveys of various control strategies can be found in [4], [23]–[25].”
BackgroundSelf-citation
Metadata
- Authors
- Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P.
- Affiliations
- Latakia University (SY)
- Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- Isfahan University of Technology (IR)
- Esfahan Electricity Power Distribution Company (EEPDC), Isfahan 81737-51387, Iran
- University of Salerno (IT)
- Corresponding author
- Siano, Pierluigi
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2018-09-20
- Volume
- 11
- Issue
- 10
- Pages
- 2497
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2890216498
- Cited by
- 349
- References
- 315
- Citations by year
- 2026: 15 · 2025: 33 · 2024: 35 · 2023: 47 · 2022: 41 · 2021: 69 · 2020: 41 · 2019: 62 · 2018: 6
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Keywords
- load frequency control, secondary frequency control, primary frequency control, power system frequency stability, smart power systems, control strategy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.