Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review
Open accessThe DOI matches its Crossref record; 306 of the 315 references it cites were found in a registry or an index.
Abstract
Power systems are the most complex systems that have been created by men in history. To operate such systems in a stable mode, several control loops are needed. Voltage frequency plays a vital role in power systems which need to be properly controlled. To this end, primary and secondary frequency control loops are used to control the frequency of the voltage in power systems. Secondary frequency control, which is called Load Frequency Control (LFC), is responsible for maintaining the frequency in a desirable level after a disturbance. Likewise, the power exchanges between different control areas are controlled by LFC approaches. In recent decades, many control approaches have been suggested for LFC in power systems. This paper presents a comprehensive literature survey on the topic of LFC. In this survey, the used LFC models for diverse configurations of power systems are firstly investigated and classified for both conventional and future smart power systems. Furthermore, the proposed control strategies for LFC are studied and categorized into different control groups. The paper concludes with highlighting the research gaps and presenting some new research directions in the field of LFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 Comparison between different objective functions, i.e., IAE, ISE, ITAE, and ITSE: ( a ) frequency deviations in different control areas; ( b ) frequency overshoot; and ( c ) frequency settling time. IAE: Integral of absolute error; ISE: integral of squared error; ITAE: integral of time multiplied by absolute error; ITSE: integral of time multiplied by squared error [295].](https://figures.cochat.ai/paper-figures/5088e2370d0d492690748566492ddd25/challenges-and-opportunities-of-load-frequency-control-in-conventional-modern-figure-4.png)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A power system's operational point may eventually experience variations from the nominal system frequency and planned power exchanges to other places, which could have a negative impact [75].”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
The cited source says what the claim attributes to it.
In the citing paper
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [75]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223
Shamseer, L., Moher, D., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., Stewart, L. A., & the PRISMA-P Group (2015) · BMJ · doi:10.1136/bmj.g7647 · Cited by 13,120
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Demand Side Management: Demand Response, Intelligent Energy Systems, and Smart Loads
Palensky, P., & Dietrich, D. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2158841 · Cited by 2,927
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
(2009) · Cited by 2,062
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Robust Power System Frequency Control
Bevrani, H. (2009) · Springer eBooks · doi:10.1007/978-0-387-84878-5 · Cited by 1,164 · cited 3×
“LFC schemes for hydro power systems under deregulation are presented in [101,102].”
BackgroundMethodKirkham, J. J., Dwan, K. M., Altman, D. G., Gamble, C., Dodd, S., Smyth, R., & Williamson, P. R. (2010) · BMJ · doi:10.1136/bmj.c365 · Cited by 1,133
Kanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985
Autonomous control of microgrids
Piagi, P., & Lasseter, R. H. (2006) · 2006 IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2006.1708993 · Cited by 830
Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems
Elgerd, O., & Fosha, C. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292602 · Cited by 810 · cited 1×
“A feedback and loop gain is used in [153] to offset the disturbances.”
MethodThe Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory
Fosha, C., & Elgerd, O. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292603 · Cited by 693 · cited 2×
“In [189], a new feedback control law for two-area interconnected power systems with non-reheat thermal power plants is designed using the regulator problem of optimal control method and a state space variable model.”
MethodStabilization of Grid Frequency Through Dynamic Demand Control
Short, J. A., Infield, D. G., & Freris, L. L. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901489 · Cited by 650
Ekanayake, J., & Jenkins, N. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827712 · Cited by 641
Delay-Dependent Stability for Load Frequency Control With Constant and Time-Varying Delays
Jiang, L., Yao, W., Wu, Q. H., Wen, J. Y., & Cheng, S. J. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2172821 · Cited by 604
Intelligent Frequency Control in an AC Microgrid: Online PSO-Based Fuzzy Tuning Approach
Bevrani, H., Habibi, F., Babahajyani, P., Watanabe, M., & Mitani, Y. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2196806 · Cited by 599 · cited 1×
“The effects of communication channel delay on LFC in three-area interconnected power systems are investigated in [64].”
BackgroundParticipation of Doubly Fed Induction Wind Generators in System Frequency Regulation
de Almeida, R. G., & Pecas Lopes, J. A. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901096 · Cited by 576
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Frequency support from doubly fed induction generator wind turbines
Ramtharan, G., Jenkins, N., & Ekanayake, J. B. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060019 · Cited by 530
Unified Tuning of PID Load Frequency Controller for Power Systems via IMC
Tan, W. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036463 · Cited by 526 · cited 3×
“In addition, the two-degree-of-freedom internal model control method for tuning the PID controller is discussed in [81,269] for load frequency control in conventional environments.”
BackgroundMethodSimulation and optimization in an AGC system after deregulation
Donde, V., Pai, M. A., & Hiskens, I. A. (2001) · IEEE Transactions on Power Systems · doi:10.1109/59.932285 · Cited by 516
Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances
Kayikci, M., & Milanovic, J. V. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016062 · Cited by 462
Mohanty, B., Panda, S., & Hota, P. K. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.06.029 · Cited by 438
Control of DFIG-Based Wind Generation for Power Network Support
Hughes, F. M., Anaya-Lara, O., Jenkins, N., & Strbac, G. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857275 · Cited by 415
Adaptive fuzzy gain scheduling for load frequency control
Talaq, J., & Al-Basri, F. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.744505 · Cited by 370 · cited 2×
“Some other issues of a hydro–thermal systems are described in [213,219,220].”
BackgroundMethodAn adaptive controller for power system load-frequency control
Pan, C.-T., & Liaw, C.-M. (1989) · IEEE Transactions on Power Systems · doi:10.1109/59.32469 · Cited by 367 · cited 1×
“An adaptive controller with proportional integral control technique to confirm the hyper-stability conditions is presented in [9] for considering the changes of plant parameters.”
MethodLoad frequency control of a realistic power system with multi-source power generation
Parmar, K. P. S., Majhi, S., & Kothari, D. P. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.040 · Cited by 364
Sahu, R. K., Panda, S., & Rout, U. K. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.12.009 · Cited by 343 · cited 2×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
MethodDecentralized Sliding Mode Load Frequency Control for Multi-Area Power Systems
Mi, Y., Fu, Y., Wang, C., & Wang, P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2277131 · Cited by 337
Application of Linear Matrix Inequalities for Load Frequency Control With Communication Delays
Yu, X., & Tomsovic, K. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831670 · Cited by 333 · cited 2×
“The linear mixed inequalities for LFC problem is proposed in [66] by considering communication delays.”
BackgroundMasuta, T., & Yokoyama, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2194746 · Cited by 322 · cited 1×
“Likewise, a coordination model between electric vehicles and heat pump water heaters is suggested for LFC in future smart grids [142].”
BackgroundLoad frequency control issues in power system operations after deregulation
Christie, R. D., & Bose, A. (1996) · IEEE Transactions on Power Systems · doi:10.1109/59.535590 · Cited by 316
Rout, U. K., Sahu, R. K., & Panda, S. (2013) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2012.10.010 · Cited by 314
Load Frequency Control of a Multi-Area Power System: An Adaptive Fuzzy Logic Approach
Yousef, H. A., AL-Kharusi, K., Albadi, M. H., & Hosseinzadeh, N. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2297432 · Cited by 314
Fractional order PID controller for load frequency control
Sondhi, S., & Hote, Y. V. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.091 · Cited by 281
BFOA based design of PID controller for two area Load Frequency Control with nonlinearities
Ali, E. S., & Abd-Elazim, S. M. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.02.030 · Cited by 270 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundSharma, Y., & Saikia, L. C. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.06.005 · Cited by 257 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundVachirasricirikul, S., & Ngamroo, I. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2264921 · Cited by 254 · cited 1×
“LFC models considering the contribution of electric vehicles (EVs) are presented in [141].”
BackgroundSliding mode based load-frequency control in power systems
Vrdoljak, K., Perić, N., & Petrović, I. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2009.10.026 · Cited by 250 · cited 1×
“A four-area interconnected power system with different energy sources and turbines such as non-reheat thermal, reheat thermal, gas, and hydro power plants is presented in [77].”
BackgroundRobust load-frequency controller design for power systems
Wang, Y., Zhou, R., & Wen, C. (1993) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1993.0003 · Cited by 248 · cited 1×
“In [11], the requirements to design the robust load frequency controller based on Riccati equation as bounds of the system parameters are found.”
Hilloowala, R. M., & Sharaf, A. M. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.485813 · Cited by 247
Enhancing Frequency Response Control by DFIGs in the High Wind Penetrated Power Systems
Chang-Chien, L.-R., Lin, W.-T., & Yin, Y.-C. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2052402 · Cited by 237
A robust decentralized load frequency controller for interconnected power systems
Dong, L., Zhang, Y., & Gao, Z. (2012) · ISA Transactions · doi:10.1016/j.isatra.2012.02.004 · Cited by 225 · cited 3×
“The LFC for multi-source power systems in which thermal, gas, and hydro energy sources are considered is proposed in [60].”
BackgroundMethodA comprehensive state of the art literature survey on LFC mechanism for power system
Shankar, R., Pradhan, S. R., Chatterjee, K., & Mandal, R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.064 · Cited by 224 · cited 1×
“Discussion on the reduction of the frequency response model order to reduce its complexity is presented in [25,39,41].”
BackgroundLoad frequency control in two area power systems using fuzzy logic controller
Çam, E., & Kocaarslan, İ. (2005) · Energy Conversion and Management · doi:10.1016/j.enconman.2004.02.022 · Cited by 223 · cited 1×
“Stochastic nature of electrical load is considered for LFC models in [31,32].”
BackgroundRay, P. K., Mohanty, S. R., & Kishor, N. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.11.011 · Cited by 222 · cited 1×
“The small signal analysis for a hybrid system is used to design a PI controller in [165].”
MethodTuning of PID load frequency controller for power systems
Tan, W. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2009.02.024 · Cited by 220 · cited 1×
“In addition, the two-degree-of-freedom internal model control method for tuning the PID controller is discussed in [81,269] for load frequency control in conventional environments.”
MethodAGC simulator for price-based operation. I. A model
Kumar, J., Ng, K.-H., & Sheble, G. (1997) · IEEE Transactions on Power Systems · doi:10.1109/59.589593 · Cited by 216
AGC of a multi-area thermal system under deregulated environment using a non-integer controller
Debbarma, S., Saikia, L. C., & Sinha, N. (2013) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.09.008 · Cited by 214 · cited 1×
“, three-area power systems [90,91,98], and four-area power systems [99,100].”
BackgroundFuzzy logic controller in interconnected electrical power systems for load-frequency control
Kocaarslan, İ., & Çam, E. (2005) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2005.06.003 · Cited by 212 · cited 3×
“Stochastic nature of electrical load is considered for LFC models in [31,32].”
BackgroundMethodPham, T. N., Trinh, H., & Hien, L. V. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2449877 · Cited by 211 · cited 1×
“HVDC transmission links between the different control areas in four-area interconnected power system are considered in [82,87], while DC transmission links are used to tie the different control area in five-area power system in [87].”
MethodDenial-of-Service (dos) attacks on load frequency control in smart grids
Liu, S., Liu, X. P., & El Saddik, A. (2013) · 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt.2013.6497846 · Cited by 208 · cited 1×
“The problems of possible cyber-attacks to LFC systems in future smart grids are discussed in [144,145].”
BackgroundThe Provision of Frequency Control Reserves From Multiple Microgrids
Yuen, C., Oudalov, A., & Timbus, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041139 · Cited by 205
A new control scheme for PID load frequency controller of single-area and multi-area power systems
Padhan, D. G., & Majhi, S. (2013) · ISA Transactions · doi:10.1016/j.isatra.2012.10.003 · Cited by 202
Investigation of domestic load control to provide primary frequency response using smart meters
Samarakoon, K., Ekanayake, J., & Jenkins, N. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2173219 · Cited by 200 · cited 1×
“Dynamic demand response which is considered as a key feature of smart grids has been developed for LFC in [138,139,149].”
BackgroundA new PID controller design for automatic generation control of hydro power systems
Khodabakhshian, A., & Hooshmand, R. (2010) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2009.11.006 · Cited by 195
Sahu, B. K., Pati, S., & Panda, S. (2014) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2014.0097 · Cited by 195
Abdelaziz, A. Y., & Ali, E. S. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.05.050 · Cited by 192 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundKhooban, M. H., & Niknam, T. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.03.017 · Cited by 191
Panda, S., & Yegireddy, N. K. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.04.003 · Cited by 190 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Load frequency control of power system under deregulated environment using optimal firefly algorithm
Chandra Sekhar, G. T., Sahu, R. K., Baliarsingh, A. K., & Panda, S. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.07.025 · Cited by 186 · cited 2×
“LFC schemes for hydro power systems under deregulation are presented in [101,102].”
BackgroundShankar, R., Chatterjee, K., & Bhushan, R. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.12.029 · Cited by 179 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
Development of Energy Storage Systems for Power Network Reliability: A Review
Mohamad, F., Teh, J., Lai, C.-M., & Chen, L.-R. (2018) · Energies · doi:10.3390/en11092278 · Cited by 178
Haes Alhelou, H., Hamedani Golshan, M. E., & Askari-Marnani, J. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.02.013 · Cited by 175 · cited 1×
“Renewable energy resources uncertainties are taken into account for LFC model in [40].”
BackgroundSelf-citationParmar, K. P. S., Majhi, S., & Kothari, D. P. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.11.058 · Cited by 171 · cited 2×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
BackgroundArya, Y., & Kumar, N. (2017) · Swarm and Evolutionary Computation · doi:10.1016/j.swevo.2016.08.002 · Cited by 169 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Ma, M., Zhang, C., Liu, X., & Chen, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2613923 · Cited by 168 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Datta, M., Senjyu, T., Yona, A., Funabashi, T., & Kim, C.-H. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2008870 · Cited by 168
Bias Due to Changes in Specified Outcomes during the Systematic Review Process
Kirkham, J. J., Altman, D. G., & Williamson, P. R. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009810 · Cited by 164
Chaudhuri, B., Pal, B. C., Zolotas, A. C., Jaimoukha, I. M., & Green, T. C. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811311 · Cited by 164
Multiobjective design of load frequency control using genetic algorithms
Daneshfar, F., & Bevrani, H. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.024 · Cited by 163 · cited 1×
“Frequency response model of three-area thermal power systems are proposed in [65,66].”
BackgroundSahu, R. K., Panda, S., & Padhan, S. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.01.020 · Cited by 160 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundArya, Y. (2017) · Energy · doi:10.1016/j.energy.2017.03.129 · Cited by 159 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
PID controller adjustment using chaotic optimisation algorithm for multi-area load frequency control
Farahani, M., Ganjefar, S., & Alizadeh, M. (2012) · IET Control Theory & Applications · doi:10.1049/iet-cta.2011.0405 · Cited by 158
Naidu, K., Mokhlis, H., & Bakar, A. H. A. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.10.022 · Cited by 157 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundOptimized multi area AGC simulation in restructured power systems
Bhatt, P. J., Roy, R., & Ghoshal, S. P. (2009) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2009.09.002 · Cited by 154 · cited 1×
“, three-area power systems [90,91,98], and four-area power systems [99,100].”
BackgroundSudha, K. R., & Santhi, R. V. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.12.027 · Cited by 151
Sahu, R. K., Gorripotu, T. S., & Panda, S. (2015) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2015.07.011 · Cited by 149
Linear Regulator Design for a Load and Frequency Control
Ćalović, M. S. (1972) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1972.293383 · Cited by 148 · cited 1×
“In [197], optimal linear regulator theory is used to design a linear regulator for load frequency control in power systems.”
BackgroundLu, C., Liu, C., & Wu, C. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.464882 · Cited by 148 · cited 1×
“LFC models for two-area power systems considering superconducting magnetic energy storage (SMES) system are proposed in [46,47].”
BackgroundAlhelou, H. H., Golshan, M. E. H., & Fini, M. H. (2018) · Electric Power Components and Systems · doi:10.1080/15325008.2018.1488895 · Cited by 148 · cited 10×
“IAE: Integral of absolute error; ISE: integral of squared error; ITAE: integral of time multiplied by absolute error; ITSE: integral of time multiplied by squared error [295].”
BackgroundMethodInfluentialSelf-citationOn Load–Frequency Regulation With Time Delays: Design and Real-Time Implementation
Bevrani, H., & Hiyama, T. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2003205 · Cited by 147 · cited 3×
“In order to regulate the frequency and tie-line power flow using communication links, decentralized proportional-integral control [162], dual mode proportional–integral (PI) controller [157] and PI control for hydropower system [158] have been proposed.”
BackgroundMethodA hybrid DE–PS algorithm for load frequency control under deregulated power system with UPFC and RFB
Sahu, R. K., Gorripotu, T. S., & Panda, S. (2015) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.03.011 · Cited by 143 · cited 1×
“Integral derivative (ID) controller for LFC is presented in [163,164].”
BackgroundRobust decentralised load-frequency control using an iterative linear matrix inequalities algorithm
Bevrani, H., Mitani, Y., & Tsuji, K. (2004) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:20040493 · Cited by 142 · cited 2×
“Thermal power system divided into three control areas are studied in [61,62].”
BackgroundKothari, M. L., Nanda, J., Kothari, D. P., & Das, D. (1989) · IEEE Transactions on Power Systems · doi:10.1109/59.193848 · Cited by 142 · cited 1×
“Discussion on discrete modeling of LFC in two-area power systems is presented in [28].”
BackgroundShimizu, K., Masuta, T., Ota, Y., & Yokoyama, A. (2010) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2010.5666064 · Cited by 141 · cited 1×
“Dynamic demand response which is considered as a key feature of smart grids has been developed for LFC in [138,139,149].”
BackgroundInfluence of photovoltaic power generation on required capacity for load frequency control
Asano, H., Yajima, K., & Kaya, Y. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.486595 · Cited by 140
Adaptive fuzzy logic load frequency control of multi-area power system
Yousef, H. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.074 · Cited by 138 · cited 1×
“LFC based on adaptive fuzzy approach is presented nto achieve better performance for several operating points [221].”
MethodChidambaram, I. A., & Paramasivam, B. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.02.004 · Cited by 138 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Chandrakala, K. R. M. V., Balamurugan, S., & Sankaranarayanan, K. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.05.009 · Cited by 137 · cited 1×
“Authors in [184,185] proposed a control method for LFC in power systems by using a variable structure control scheme.”
MethodDash, P., Saikia, L. C., & Sinha, N. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.10.015 · Cited by 136 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundBhatt, P. J., Roy, R., & Ghoshal, S. P. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.12.015 · Cited by 133 · cited 1×
“Two-area power system frequency response models consisting of reheat-thermal turbines connected by AC/DC links are presented in [35,42,43].”
BackgroundContribution of DFIG-based wind farms to power system short-term frequency regulation
Anaya‐Lara, O., Hughes, F. M., Jenkins, N., & Štrbac, G. (2006) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:20050264 · Cited by 133 · cited 1×
“Frequency response models suitable for power systems with high penetration of renewable energy sources are suggested in [112,113,122].”
BackgroundMorsali, J., Zare, K., & Hagh, M. T. (2016) · Engineering Science and Technology an International Journal · doi:10.1016/j.jestch.2016.06.002 · Cited by 133 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
Automatic generation control of multi source power generation under deregulated environment
Hota, P. K., & Mohanty, B. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.09.003 · Cited by 127 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
Fini, M. H., Yousefi, G. R., & Alhelou, H. H. (2016) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2015.1334 · Cited by 127 · cited 2×
“Recently, the objective function given in Equation (6) considering the damping of the frequency oscillations and the settling time of both frequency error and tie-lines error, such that the power balance is attained as soon as possible, is proposed for LFC [318].”
BackgroundMethodSelf-citationBhatt, P. J., Roy, R., & Ghoshal, S. P. (2009) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2009.09.004 · Cited by 126 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Jagatheesan, K., Anand, B., Samanta, S., Dey, N., Santhi, V., Ashour, A. S., & Bălaş, V. E. (2016) · Neural Computing and Applications · doi:10.1007/s00521-016-2361-1 · Cited by 124
Pappachen, A., & Fathima, A. P. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.04.032 · Cited by 123 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Zare, K., Hagh, M. T., & Morsali, J. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.10.009 · Cited by 119 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Robust PI control of smart controllable load for frequency stabilization of microgrid power system
Nandar, C. S. A. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.10.032 · Cited by 115
Dhundhara, S., & Verma, Y. P. (2018) · Energy · doi:10.1016/j.energy.2018.01.076 · Cited by 115 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced Dump Load
Doolla, S., & Bhatti, T. S. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.881157 · Cited by 112 · cited 1×
“In [14], a frequency response model of electric power systems consisting of hydro power plants is well-described.”
BackgroundSingh, B., & Kasal, G. K. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.918620 · Cited by 110
Decentralized load frequency control in deregulated environments
Tan, W., Zhang, H., & Yu, M. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.02.013 · Cited by 109 · cited 2×
“An internal model control method with two-degree-of-freedom is used in [99] to tune decentralized PID controller of the load frequency control in four-area power system.”
BackgroundMethodRobust decentralised load–frequency control of multi-area power systems
Lim, K. Y., Wang, Y., & Zhou, R. (1996) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19960452 · Cited by 108 · cited 3×
“A new robust decentralized load frequency controller based on the Riccati-equation is proposed in [226] for multi-area power systems considering the uncertainties of parameters.”
MethodInfluentialImpacts of Energy Storage System on Power System Reliability: A Systematic Review
Mohamad, F., & Teh, J. (2018) · Energies · doi:10.3390/en11071749 · Cited by 108
Robust analysis and design of power system load frequency control using the Kharitonov's theorem
Toulabi, M., Shiroei, M., & Ranjbar, A. M. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.08.014 · Cited by 105
Load-frequency control of interconnected power systems via constrained feedback control schemes
Aldeen, M., & Trinh, H. M. (1994) · Computers & Electrical Engineering · doi:10.1016/0045-7906(94)90008-6 · Cited by 104 · cited 1×
“The centralized control scheme is based on classes of disturbances of the system [154,202].”
MethodRobust analysis and design of load frequency controller for power systems
Tan, W., & Xu, Z. W. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2008.11.005 · Cited by 102
AGC simulator for price-based operation. II. Case study results
Kumar, J., Ng, K.-H., & Sheblé, G. B. (1997) · IEEE Transactions on Power Systems · doi:10.1109/59.589596 · Cited by 100
Optimal Decentralized Load Frequency Control
Feliachi, A. (1987) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.1987.4335137 · Cited by 98
AGC of two area power system interconnected by AC/DC links with diverse sources in each area
Ibraheem, Nizamuddin, & Bhatti, T. S. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.09.017 · Cited by 98
Adaptive neuro-fuzzy inference system based automatic generation control
Hosseini, S. H., & Etemadi, A. H. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2007.10.007 · Cited by 97
A load frequency control algorithm based on a generalized approach
Malik, O. P., Kumar, A., & Hope, G. S. (1988) · IEEE Transactions on Power Systems · doi:10.1109/59.192887 · Cited by 97
A new approach to the design of robust load-frequency controller for large scale power systems
Ray, G., Prasad, A. N., & Prasad, G. D. (1999) · Electric Power Systems Research · doi:10.1016/s0378-7796(98)00125-4 · Cited by 96 · cited 2×
“A robust control scheme is proposed in [224,225] based on the Riccati equation for a single area thermal power system.”
MethodMulti-area adaptive LFC developed for a comprehensive AGC simulator
Shoults, R. R., & Ibarra, J. (1993) · IEEE Transactions on Power Systems · doi:10.1109/59.260829 · Cited by 95 · cited 1×
“A reduced order adaptive controller for LFC is suggested in [212] and a multi-area adaptive load frequency control strategy is developed in [211].”
MethodThe optimal decentralized control of a large power system: Load and frequency control
Davison, E. J., & Tripathi, N. (1978) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1978.1101708 · Cited by 95
Morsali, J., Zare, K., & Hagh, M. T. (2015) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.11.012 · Cited by 94 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Adaptive automatic generation control with superconducting magnetic energy storage in power systems
Tripathy, S. C., Balasubramanian, R., & Nair, P. S. C. (1992) · IEEE Transactions on Energy Conversion · doi:10.1109/60.148563 · Cited by 93 · cited 2×
“LFC models for two-area power systems considering superconducting magnetic energy storage (SMES) system are proposed in [46,47].”
BackgroundMethodHierarchical plug-in EV control based on primary frequency response in interconnected smart grid
Alhelou, H. H., & Golshan, M. E. H. (2016) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2016.7585585 · Cited by 91
Self-citationDecentralised power system load frequency control beyond the limit of diagonal dominance
Yang, T., Ding, Z., & Yu, H. (2002) · International Journal of Electrical Power & Energy Systems · doi:10.1016/s0142-0615(01)00028-x · Cited by 90 · cited 1×
“A decentralized power system load frequency control method exceeding the diagonal dominance limit is described in [243,246,256].”
MethodDecentralised load-frequency controller design based on structured singular values
Yang, T. C., Çimen, H., & Zhu, Q. (1998) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19981716 · Cited by 89 · cited 3×
“A decentralized LFC based on structured singular values was proposed in [78].”
BackgroundMethodNew robust adaptive load-frequency control with system parametric uncertainties
Wang, Y. (1994) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19949757 · Cited by 88 · cited 2×
“A new adaptive LFC considering uncertainties of parameters is proposed in [12] with a combination of robust control, the Riccati equation and adaptive control.”
MethodMulti agent electric vehicle control based primary frequency support for future smart micro-grid
Alhelou, H. H., Golshan, M. E. H., & Fini, M. H. (2015) · Smart Grid Conference · doi:10.1109/sgc.2015.7857385 · Cited by 88
Self-citationOn robust control analysis and design for load frequency regulation
Stanković, A. M., Tadmor, G., & Sakharuk, T. A. (1998) · IEEE Transactions on Power Systems · doi:10.1109/59.667367 · Cited by 87 · cited 1×
“In [227], analysis and heuristic design guidelines of LFC based on quantitative feedback theory is suggested to offer an orderly methodology for control system synthesis.”
MethodDecentralized load frequency controller for a multi-area interconnected power system
Alrifai, M. T., Hassan, M. F., & Zribi, M. (2010) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.08.015 · Cited by 87 · cited 1×
“A decentralized load frequency control method for interconnected three-area power system is presented in [270].”
MethodDelayed inputs attack on load frequency control in smart grid
Sargolzaei, A., Yen, K. K., & Abdelghani, M. (2014) · IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt.2014.6816508 · Cited by 87 · cited 1×
“The problems of possible cyber-attacks to LFC systems in future smart grids are discussed in [144,145].”
BackgroundAlhelou, H. H., Hamedani-Golshan, M. E., Heydarian‐Forushani, E., Al‐Sumaiti, A. S., & Siano, P. (2018) · International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest.2018.8495858 · Cited by 86
Self-citationDecentralized load frequency control using a new robust optimal MISO PID controller
Yazdizadeh, A., Ramezani, H., & Hamedrahmat, E. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2011.09.007 · Cited by 85 · cited 1×
“Chaotic optimization algorithm is used for determining the parameters of PID controller in multi-area load frequency control in [168].”
MethodSahu, R. K., Gorripotu, T. S., & Panda, S. (2015) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2014.12.009 · Cited by 82
Robust multivariable predictive based load frequency control considering generation rate constraint
Shiroei, M., Toulabi, M., & Ranjbar, A. M. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.10.039 · Cited by 81
Robust analysis of decentralized load frequency control for multi-area power systems
Tan, W., & Zhou, H. L. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.05.063 · Cited by 81 · cited 2×
“The robust analysis for decentralized LFC for multi-area power system is described in [239] where a robustness analysis against variation of the structure and magnitude variation in the tie-line power flow network is proposed.”
MethodImpact of energy storage units on load frequency control of deregulated power systems
Selvaraju, R. K., & Ganapathy, S. (2016) · Energy · doi:10.1016/j.energy.2015.12.121 · Cited by 81 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
A New Combined Model for Simulation of Mutual Effects between LFC and AVR Loops
Rakhshani, E., Rouzbehi, K., & Sadeh, S. (2009) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2009.4918066 · Cited by 79 · cited 1×
“The interaction between the active and reactive power controls and their impacts on LFC models of single-area power systems are illustrated in [10].”
BackgroundLFC based adaptive PID controller using ANN and ANFIS techniques
Mosaad, M. I., & Salem, F. (2014) · Journal of Electrical Systems and Information Technology · doi:10.1016/j.jesit.2014.12.004 · Cited by 77
Area automatic generation control by multi-pass dynamic programming
Bechert, T. E., & Chen, N. (1977) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/t-pas.1977.32474 · Cited by 77
Optimal observer design for load-frequency control
Yamashita, K., & Taniguchi, T. (1986) · International Journal of Electrical Power & Energy Systems · doi:10.1016/0142-0615(86)90003-7 · Cited by 77 · cited 1×
“State estimator with decaying error using a nonlinear transformation based on optimal observer for AGC schemes is presented in [194].”
MethodGenetic algorithms applications in load frequency control
Abdel-Magid, Y. L. (1995) · doi:10.1049/cp:19951050 · Cited by 75 · cited 1×
“As a first work in this topic, genetic algorithm (GA) has been proposed as a promising technique for solving LFC problem and other power system problems in [271].”
MethodSecondary Load-Frequency Control for MicroGrids in Islanded Operation.
Madureira, A., Moreira, C., & Lopes, J. P. (2017) · Renewable Energy and Power Quality Journal · doi:10.24084/repqj03.335 · Cited by 75 · cited 1×
“Non-linear microgrid models for LFC studies are also suggested in [130,131].”
BackgroundAdaptive load-frequency control of the hungarian power system
Vajk, I., Vajta, M., Keviczky, L., Haber, R. E., Hetthéssy, J., & Kovacs, K. P. (1985) · Automatica · doi:10.1016/0005-1098(85)90108-6 · Cited by 74
Supervisory predictive control of power system load frequency control
Shiroei, M., & Ranjbar, A. M. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.03.020 · Cited by 73
A novel quasi-oppositional harmony search algorithm for automatic generation control of power system
Shiva, C. K., & Mukherjee, V. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.05.054 · Cited by 73 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundAn Optimal Photovoltaic Conversion System for Future Smart Grids
Makdisie, C. J., Haidar, B., & Alhelou, H. H. (2018) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-3935-3.ch018 · Cited by 71
Self-citationNaidu, K., Mokhlis, H., Bakar, A. H. A., Terzija, V. V., & Illias, H. A. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.05.055 · Cited by 70 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundImproved load-frequency self-tuning regulator
Sheirah, M. A., & ABD-EL-FATTAH, M. M. (1984) · International Journal of Control · doi:10.1080/00207178408933155 · Cited by 69
Wind Turbine Generator Interaction With Diesel Generators on an Isolated Power System
Scott, G. W., Wilreker, V. F., & Shaltens, R. K. (1984) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1984.318695 · Cited by 69 · cited 1×
“Frequency response models suitable for power systems with high penetration of renewable energy sources are suggested in [112,113,122].”
BackgroundMicroprocessor-based adaptive load-frequency control
Kanniah, J., Tripathy, S. C., Malik, O. P., & Hope, G. S. (1984) · IEE Proceedings C Generation Transmission and Distribution · doi:10.1049/ip-c.1984.0020 · Cited by 69
Liu, X., Kong, X., & Lee, K. Y. (2016) · IET Control Theory and Applications · doi:10.1049/iet-cta.2015.1021 · Cited by 67 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Das, D., Nanda, J., Kothari, M. L., & Kothari, D. P. (1990) · Electric Machines & Power Systems · doi:10.1080/07313569008909490 · Cited by 65
Robust automatic generation control
Azzam, M. (1999) · Energy Conversion and Management · doi:10.1016/s0196-8904(99)00040-0 · Cited by 65
Intelligent controllers for automatic generation control
Kumar, D. M. V. (2002) · doi:10.1109/tencon.1998.798284 · Cited by 64 · cited 1×
“Discussion on the reduction of the frequency response model order to reduce its complexity is presented in [25,39,41].”
BackgroundAutomatic generation control: Decentralized area-wise optimal solution
Ćalović, M. S. (1984) · Electric Power Systems Research · doi:10.1016/0378-7796(84)90021-x · Cited by 64 · cited 1×
“A decentralized controller for the load frequency control problem is presented in [70,241,242,246,253] using tunable”
MethodAdaptive Polar Fuzzy logic based Load Frequency Controller
Chaturvedi, D. K., Umrao, R., & Malik, O. P. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.10.024 · Cited by 63 · cited 1×
“A combination of AC transmission lines and HVDC/DC links is used to tie two control-area power system, which can be viewed in [83,84].”
BackgroundMultilevel load-frequency control of interconnected power systems
Bengiamin, N. N., & Chan, W. C. (1978) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1978.0126 · Cited by 63 · cited 1×
“Thermal power system divided into three control areas are studied in [61,62].”
BackgroundAn optimal tracking approach to load-frequency control
Kwatny, H. G., Kalnitsky, K. C., & Bhatt, A. (1975) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/t-pas.1975.32006 · Cited by 63 · cited 1×
“In [199], a survey of optimal linear regulator theory and its application for LFC is presented.”
BackgroundMahto, T., & Mukherjee, V. (2017) · Energy · doi:10.1016/j.energy.2017.04.155 · Cited by 63 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Hierarchical optimal robust load-frequency control for power systems
Rahmani, M., & Sadati, N. (2012) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2011.0544 · Cited by 62 · cited 1×
“LFC for three-area consisting of reheat thermal units connected by a tie-line to another hydro control area is presented in [57].”
BackgroundHsu, Y., & Chan, W. C. (1984) · International Journal of Electrical Power & Energy Systems · doi:10.1016/0142-0615(84)90004-8 · Cited by 62 · cited 1×
“Regarding to variable structure theory and optimal linear control, in [223] a LFC method for interconnected two-are hydro–thermal systems was proposed.”
MethodSelf-tuning algorithm for automatic generation control in an interconnected power system
Lee, K. A., Yee, H., & Teo, C. Y. (1991) · Electric Power Systems Research · doi:10.1016/0378-7796(91)90060-z · Cited by 61 · cited 1×
“In [214], a self-tuning method for the load frequency control problem of interconnected power systems is presented.”
MethodMulti area AGC scheme using imperialist competition algorithm in restructured power system
Kumar, N., Kumar, V., & Tyagi, B. (2016) · Applied Soft Computing · doi:10.1016/j.asoc.2016.07.005 · Cited by 61 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Automatic Generation Control Part II-Digital Control Techniques
deMello, F. P., Mills, R., & B'Rells, W. (1973) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1973.293777 · Cited by 60 · cited 1×
“By using modeling error compensation technique, the design of decentralized LFC method for power system consisting of two-area with a thermal generation, starting with stochastic state and output models is proposed in [251,252].”
MethodError Adaptive Control Computer for Interconnected Power Systems
Ross, C. W. (1966) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1966.291701 · Cited by 60 · cited 1×
“The adaptive control criteria and the practical difficulties found in LFC to achieve this criterion are presented in [209].”
BackgroundDecentralised load-frequency control
Geromel, J. C., & Peres, P. L. D. (1985) · IEE Proceedings D Control Theory and Applications · doi:10.1049/ip-d.1985.0039 · Cited by 60
Self-tuning load frequency control: multilevel adaptive approach
Rubaai, A. (1994) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:19949964 · Cited by 59 · cited 2×
“Some other issues of a hydro–thermal systems are described in [213,219,220].”
BackgroundNoninteracting Controls of Interconnected Electric Power Systems
Quazza, G. (1966) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1966.291700 · Cited by 59 · cited 2×
“The centralized control scheme is based on classes of disturbances of the system [154,202].”
MethodImproved particle swarm optimization based load frequency control in a single area power system
Gautam, S. K., & Goyal, N. (2010) · IEEE India Conference · doi:10.1109/indcon.2010.5712725 · Cited by 59 · cited 1×
“In [272,273], LFC problem in single-area power systems is solved by PSO.”
BackgroundTechniques for Improving the Control of Bulk Power Transfers on Interconnected Systems
Cohn, N. (1971) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1971.292851 · Cited by 55 · cited 1×
“The coordinated system-based technique for correcting the time error and unintentional interchange is presented for AGC in [187,188].”
MethodChaine, S., & Tripathy, M. (2015) · Journal of Electrical Systems and Information Technology · doi:10.1016/j.jesit.2015.03.001 · Cited by 55
Kanellos, F. D., & Hatziargyriou, N. D. (2008) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20080023 · Cited by 55
Marimuthu, P., Banakara, B., Dash, S. S., & Veerasamy, M. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.06.019 · Cited by 54 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Optimum Load-Frequency Sampled-Data Control with Randomly Varying System Disturbances
Bohn, E., & Miniesy, S. (1972) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1972.293519 · Cited by 54
Load-frequency control of isolated wind-diesel-microhydro hybrid power systems (WDMHPS)
Bhatti, T. S., Al-Ademi, A. A. F., & Bansal, N. K. (1997) · Energy · doi:10.1016/s0360-5442(96)00148-x · Cited by 54
Gholipour, E., & Nosratabadi, S. M. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.020 · Cited by 53 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundYamashita, K., & Miyagi, H. (1991) · IEE Proceedings D Control Theory and Applications · doi:10.1049/ip-d.1991.0025 · Cited by 52 · cited 1×
“A self-tuning regulator for LFC considering the interaction between voltage and frequency control loops is presented in [218].”
BackgroundShiva, C. K., & Mukherjee, V. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.11.051 · Cited by 52 · cited 2×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundMulti Area Load Frequency Control Using Particle Swarm Optimization and Fuzzy Rules
Dhillon, S. S., Lather, J. S., & Marwaha, S. (2015) · Procedia Computer Science · doi:10.1016/j.procs.2015.07.363 · Cited by 51
Xi, L., Yu, T., Yang, B. F., & Zhang, X. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.06.030 · Cited by 50
Optimal Decentralized Load Frequency Control Using HPSO Algorithms in Deregulated Power Systems
Taher, S. A., Hematti, R., Abdolalipo, A., & Tabei, S. H. (2008) · American Journal of Applied Sciences · doi:10.3844/ajassp.2008.1167.1174 · Cited by 49 · cited 1×
“The multivariable quantitative feedback theory is used in [266] for a load frequency controller in multi-area power systems with system parametric uncertainties.”
MethodIbraheem, & Kumar, P. (2003) · Electric Power Components and Systems · doi:10.1080/15325000390203638 · Cited by 44 · cited 1×
“A combination of AC transmission lines and HVDC/DC links is used to tie two control-area power system, which can be viewed in [83,84].”
BackgroundNgamroo, I., Tippayachai, J., & Dechanupaprittha, S. (2006) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2006.01.005 · Cited by 44 · cited 1×
“A robust decentralized frequency stabilizer design for static synchronous series compensators was proposed in [235] which considers the uncertainties of a three-area interconnected power system.”
BackgroundLoad following in a bilateral market with local controllers
Abraham, R. J., Das, D., & Patra, A. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2011.06.033 · Cited by 44
Kumar, A., Malik, O. P., & Hope, G. S. (1987) · IEE Proceedings C Generation Transmission and Distribution · doi:10.1049/ip-c.1987.0017 · Cited by 44
Kouba, N. E. Y., Menaa, M., Hasni, M., & Boudour, M. (2015) · International Conference on Systems and Control (ICSC) · doi:10.1109/icosc.2015.7152777 · Cited by 43
Automatic Generation Control Part I-Process Modeling
Mills, R., & B'Rells, W. (1973) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1973.293776 · Cited by 43 · cited 1×
“By using modeling error compensation technique, the design of decentralized LFC method for power system consisting of two-area with a thermal generation, starting with stochastic state and output models is proposed in [251,252].”
MethodLoad-frequency control and inadvertent interchange evaluation in restructured power systems
Delfino, B., Fornari, F., & Massucco, S. (2002) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:20020368 · Cited by 43
Identification-based power unit model for load-frequency control purposes
Hain, Y., Kulessky, R., & Nudelman, G. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.898107 · Cited by 43
Load frequency control using battery energy storage system in interconnected power system
Kalyani, S., Nagalakshmi, S., & Marisha, R. (2012) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt.2012.6396052 · Cited by 42 · cited 1×
“Integral of absolute error (IAE) [162,318], integral of time multiplied by absolute error (ITAE) [319], integral of squared error (ISE) [102,320] and integral of time multiplied by squared error (ITSE) [170,295,321] are the most important criteria used for designing load frequency controllers.”
MethodSolving LFC problem in an interconnected power system using superconducting magnetic energy storage
Farahani, M. A., & Ganjefar, S. (2013) · Physica C Superconductivity · doi:10.1016/j.physc.2013.02.005 · Cited by 41 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Regulation Error in Load Frequency Control
Bose, A., & Atiyyah, I. (1980) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1980.319656 · Cited by 41
Optimal transient droop compensator and PID tuning for load frequency control in hydro power systems
de Oliveira, E. J., Honório, L. D. M., Anzai, A. H., de Oliveira, L. W., & Costa, E. B. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.071 · Cited by 41
Considerations in the Regulation of Interconnected Areas
Cohn, N. (1967) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1967.291937 · Cited by 41 · cited 1×
“The coordinated system-based technique for correcting the time error and unintentional interchange is presented for AGC in [187,188].”
MethodDesign of Dual Mode PI Controller for Load Frequency Control
Chatterjee, K. (2010) · International Journal of Emerging Electric Power Systems · doi:10.2202/1553-779x.2452 · Cited by 40 · cited 1×
“In order to regulate the frequency and tie-line power flow using communication links, decentralized proportional-integral control [162], dual mode proportional–integral (PI) controller [157] and PI control for hydropower system [158] have been proposed.”
Optimal decentralized load frequency control
Park, Y. M., & Lee, K. Y. (1984) · Electric Power Systems Research · doi:10.1016/0378-7796(84)90012-9 · Cited by 40
Application of SMES coordinated with solid-state phase shifter to load frequency control
Ngamroo, I., Mitani, Y., & Tsuji, K. (1999) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.783300 · Cited by 39 · cited 1×
“In [48], a frequency control model for two-area power systems considering the contribution of batteries and SMES is described.”
MethodA novel classical controller for automatic generation control in thermal and hydrothermal systems
Nanda, J., Mishra, S., Mishra, P. G., & Sajith, K. V. (2010) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2010.5712439 · Cited by 39 · cited 1×
“Integral derivative (ID) controller for LFC is presented in [163,164].”
BackgroundShiva, C. K., & Mukherjee, V. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.06.016 · Cited by 38 · cited 1×
“For instance, differential evolution (DE) algorithm [170,276–279], firefly algorithm (FA) [173,280,281], bacterial foraging optimization (BFO) [282,283], artificial bee colony (ABC) [174,284], bat inspired algorithm (BIA) [285–287], quasi oppositional (QO) [54], quasi-oppositional harmony search (QOHS) algorithm [288,…”
BackgroundMULTI STAGE FUZZY PID LOAD FREQUENCY CONTROLLER IN A RESTRUCTURED POWER SYSTEM
Shayeghi, H., Shayanfar, H. A., & Jalili, A. (2007) · Cited by 38
Application of capacitive energy storage for transient performance improvement of power system
Mukherjee, V., & Ghoshal, S. P. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2008.06.013 · Cited by 36 · cited 1×
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Research works printed but not linked: 14
- Concordia, 1953, Tie-line power and frequency control of electric power systems, Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst., 72, 562
- Concordia, 1954, Tie-line power and frequency control of electric power systems-Part II, Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst., 73, 133
- Chokpanyasuwan, C. (2008, January 12–14). Robot Fuzzy logic-PID Controller for Wind-Diesel Power System using Particle Swarm Optimization. Proceedings of the GMSARN International Conference on Sustainable Development: Issues and Prospects for the GMS, Kunming, China.
- Hilloowala, R.M., and Sharaf, A.M. (1993, January 2–8). A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme. Proceedings of the Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting, Toronto, ON, Canada.
- Lasseter, R.H. (2002, January 27–31). Microgrids. Proceedings of the Power Engineering Society Winter Meeting, New York, NY, USA.
- Lakshmi, 2014, Pso based load frequency control for single area power system, Int. J. Sci. Eng. Res., 5, 12
- Velusami, 1997, Design of observer-based decentralized load-frequency controllers for interconnected power systems, Int. J. Power Energy Syst., 17, 152
- Feliachi, 1987, Load frequency control using reduced order models and local observers, Int. J. Energy Syst., 7, 72
- Rao, C.S. (2012, January 30–31). Adaptive Neuro Fuzzy based Load Frequency Control of multi area system under open market scenario. Proceedings of the 2012 International Conference on Advances in Engineering, Science and Management (ICAESM), Nagapattinam, India.
- Karrari, 1999, Design of H∞ controller load frequency control in electrical power systems, Amirkabir J. Sci. Technol., 11, 79
- Bevrani, H. (1999, January 22–27). Robust load frequency controller in a deregulated environment: A/spl mu/-synthesis approach. Proceedings of the 1999 IEEE International Conference on Control Applications, Kohala Coast, HI, USA.
- Bensenouci, A., and Ghany, A.A. (2007, January 9–12). Mixed H∞/H2 with pole-placement design of robust LMI-based output feedback controllers for multi-area load frequency control. Proceedings of the International Conference on “Computer as a Tool” (EUROCON 2007), Warsaw, Poland.
- Chidambaram, 2009, Genetic algorithm based decentralized controller for load-frequency control of interconnected power systems with RFB considering TCPS in the tie-line, Int. J. Electron. Eng. Res., 1, 299
- Balasundaram, 2012, ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB, Int. J. Eng. Innov. Technol., 1, 1
Cited by
A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges
Haes Alhelou, H., Hamedani-Golshan, M. E., Njenda, T. C., & Siano, P. (2019) · Energies · doi:10.3390/en12040682 · Cited by 643
“The ability of power systems to maintain stability and to ensure continuous supply of electrical power to customers in the event of a disturbance is of critical importance [5,14].”
BackgroundSelf-citationEnergy systems for climate change mitigation: A systematic review
Kang, J.-N., Wei, Y.-M., Liu, L.-C., Han, R., Yu, B.-Y., & Wang, J.-W. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114602 · Cited by 276
Alhamrouni, I., Abdul Kahar, N. H., Salem, M., Swadi, M., Zahroui, Y., Kadhim, D. J., Mohamed, F. A., & Alhuyi Nazari, M. (2024) · Applied Sciences · doi:10.3390/app14146214 · Cited by 217
“Alhelou et al. [75] mentioned that the solution to some AGC issues exhibits FL and ANN hybridization.”
BackgroundJi, W., Hong, F., Zhao, Y., Lu, L., Du, H., Hao, J., Fang, F., & Liu, J. (2024) · Renewable Energy · doi:10.1016/j.renene.2024.119975 · Cited by 176
Alhelou, H. H., Golshan, M. E. H., & Hatziargyriou, N. D. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2916558 · Cited by 151
“For interested readers, comprehensive surveys of various control strategies can be found in [4], [23]–[25].”
BackgroundSelf-citation
Metadata
- Authors
- Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P.
- Affiliations
- Latakia University (SY)
- Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- Isfahan University of Technology (IR)
- Esfahan Electricity Power Distribution Company (EEPDC), Isfahan 81737-51387, Iran
- University of Salerno (IT)
- Corresponding author
- Siano, Pierluigi
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2018-09-20
- Volume
- 11
- Issue
- 10
- Pages
- 2497
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2890216498
- Cited by
- 349
- References
- 315
- Citations by year
- 2026: 15 · 2025: 33 · 2024: 35 · 2023: 47 · 2022: 41 · 2021: 69 · 2020: 41 · 2019: 62 · 2018: 6
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Keywords
- load frequency control, secondary frequency control, primary frequency control, power system frequency stability, smart power systems, control strategy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.