CoChat

SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction

Open access
Adamowicz, Marek, Szewczyk, Janusz · 2020 · Energies

The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.

Abstract

The design of rolling stock plays a key role in the attractiveness of the rail transport. Train design must strictly meet the requirements of rail operators to ensure high quality and cost-effective services. Semiconductor power devices made from silicon carbide (SiC) have reached a level of technology enabling their widespread use in traction power converters. SiC transistors offering energy savings, quieter operation, improved reliability and reduced maintenance costs have become the choice for the next-generation railway power converters and are quickly replacing the IGBT technology which has been used for decades. The paper describes the design and development of a novel SiC-based DC power electronic traction transformer (PETT) intended for electric multiple units (EMUs) operated in 3 kV DC rail traction. The details related to the 0.5 MVA peak power medium voltage prototype, including the electrical design of the main building blocks are presented in the first part of the paper. The second part deals with the implementation of the developed SiC-based DC PETT into a regional train operating on a 3 kV DC traction system. The experimental results obtained during the testing are presented to demonstrate the performance of the developed 3 kV DC PETT prototype.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en13215573

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Conventional electric drive of 3 kV DC traction rolling stock with asynchronous traction motor and 6.5 kV IGBT-based two-level inverter: Lf, Cf -inductance and capacitance of the traction line filter; TM&G -traction motor and gear, w -wheels ( a ); Typical collector-emitter voltage (1) and Figure 1. Conventional electric drive of 3 kV DC traction rolling stock with asynchronous traction motor and 6.5 kV IGBT-based two-level inverter: Lf , Cf -inductance and capacitance of the traction line filter; TM&G-traction motor and gear, w-wheels ( a ); Typical collector-emitter voltage (1) and collector current (2) transients during switching of the 6.5 kV IGBT, 4 µ s / div ( b ); Typical drain-source voltage (1) and drain current (2) transients during switching of the 10 kV SiC MOSFET, 500 ns / div ( c ) (comparison in the text).
Figure 1 Conventional electric drive of 3 kV DC traction rolling stock with asynchronous traction motor and 6.5 kV IGBT-based two-level inverter: Lf, Cf -inductance and capacitance of the traction line filter; TM&G -traction motor and gear, w -wheels ( a ); Typical collector-emitter voltage (1) and Figure 1. Conventional electric drive of 3 kV DC traction rolling stock with asynchronous traction motor and 6.5 kV IGBT-based two-level inverter: Lf , Cf -inductance and capacitance of the traction line filter; TM&G-traction motor and gear, w-wheels ( a ); Typical collector-emitter voltage (1) and collector current (2) transients during switching of the 6.5 kV IGBT, 4 µ s / div ( b ); Typical drain-source voltage (1) and drain current (2) transients during switching of the 10 kV SiC MOSFET, 500 ns / div ( c ) (comparison in the text).CC-BY · From the PDF
Figure 2 The EN81 series 3 kV DC electric passenger railcar used for the field trial with the roofmounted SiC-based DC power electronic traction transformer (PETT) prototype. Figure 2. TheEN81series3kVDCelectricpassengerrailcar used for the field trial with the roof-mounted SiC-based DC power electronic traction transformer (PETT) prototype.
Figure 2 The EN81 series 3 kV DC electric passenger railcar used for the field trial with the roofmounted SiC-based DC power electronic traction transformer (PETT) prototype. Figure 2. TheEN81series3kVDCelectricpassengerrailcar used for the field trial with the roof-mounted SiC-based DC power electronic traction transformer (PETT) prototype.CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Figure 4 Assembly of power electronic cells of the DC PETT on the roof surface: ( a ) overall view of the whole device from the CAD program; detailed view of the 4QC-DAB-DC/AC power electronic cells and the LCL filter in the middle at the bottom ( b ); photos of the prototype ( c ) and ( d ). Figure 4. Assembly of power electronic cells of the DC PETT on the roof surface: ( a ) overall view of the whole device from the CAD program; detailed view of the 4QC-DAB-DC / ACpower electronic cells and the LCL filter in the middle at the bottom ( b ); photos of the prototype ( c ) and ( d ).
Figure 4 Assembly of power electronic cells of the DC PETT on the roof surface: ( a ) overall view of the whole device from the CAD program; detailed view of the 4QC-DAB-DC/AC power electronic cells and the LCL filter in the middle at the bottom ( b ); photos of the prototype ( c ) and ( d ). Figure 4. Assembly of power electronic cells of the DC PETT on the roof surface: ( a ) overall view of the whole device from the CAD program; detailed view of the 4QC-DAB-DC / ACpower electronic cells and the LCL filter in the middle at the bottom ( b ); photos of the prototype ( c ) and ( d ).CC-BY · From the PDF
Figure 5 The 1.2 kV SiC MOSFET power module, part no. CAS120M12BM2, used in the project, with a rated current of 138 A (left) and a 36% smaller 1.2 kV SiC MOSFET power module, part no. CAB450M12XM3, with a rated current of 409A, available on the market from mid-2019. Figure 5. The 1.2 kV SiC MOSFET power module, part no. CAS120M12BM2, used in the project, with a rated current of 138 A (left) and a 36% smaller 1.2 kV SiC MOSFET power module, part no. CAB450M12XM3, with a rated current of 409A, available on the market from mid-2019.
Figure 5 The 1.2 kV SiC MOSFET power module, part no. CAS120M12BM2, used in the project, with a rated current of 138 A (left) and a 36% smaller 1.2 kV SiC MOSFET power module, part no. CAB450M12XM3, with a rated current of 409A, available on the market from mid-2019. Figure 5. The 1.2 kV SiC MOSFET power module, part no. CAS120M12BM2, used in the project, with a rated current of 138 A (left) and a 36% smaller 1.2 kV SiC MOSFET power module, part no. CAB450M12XM3, with a rated current of 409A, available on the market from mid-2019.CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 SiC MOSFET drain-source voltage (1), 100 V/div and the primary MFT current (2), 25 A/div of the developed DAB DC-DC converter during commutation of 700V DC voltage, 400 ns/div. Figure 7. SiC MOSFET drain-source voltage (1), 100 V / div and the primary MFT current (2), 25 A / div of the developed DAB DC-DC converter during commutation of 700V DC voltage, 400 ns / div.
Figure 7 SiC MOSFET drain-source voltage (1), 100 V/div and the primary MFT current (2), 25 A/div of the developed DAB DC-DC converter during commutation of 700V DC voltage, 400 ns/div. Figure 7. SiC MOSFET drain-source voltage (1), 100 V / div and the primary MFT current (2), 25 A / div of the developed DAB DC-DC converter during commutation of 700V DC voltage, 400 ns / div.CC-BY · From the PDF
Figure 8 Main dimensions ( a ); and the overall view ( b ) of the first developed MFT with concentric windings of cylindrical shape (auxiliary inductor visible in the right top corner). Figure 8. Main dimensions ( a ); and the overall view ( b ) of the first developed MFT with concentric windings of cylindrical shape (auxiliary inductor visible in the right top corner).
Figure 8 Main dimensions ( a ); and the overall view ( b ) of the first developed MFT with concentric windings of cylindrical shape (auxiliary inductor visible in the right top corner). Figure 8. Main dimensions ( a ); and the overall view ( b ) of the first developed MFT with concentric windings of cylindrical shape (auxiliary inductor visible in the right top corner).CC-BY · From the PDF
Figure 9 Primary MFT current i TR (25 A/div) and drain-source voltage v DS (100 V/div) of the SiC MOSFET of the DAB DC-DC converter operating with 20 kHz switching frequency and the DPS modulation (20 µs/div) ( a ); temperature measurement of the amorphous alloy core and observed heating of individual coils as a result of the proximity effect at rated power ( b ). Figure 9. Primary MFT current i TR (25 A / div) and drain-source voltage v DS (100 V / div) of the SiC MOSFET of the DAB DC-DC converter operating with 20 kHz switching frequency and the DPS modulation (20 µ s / div) ( a ); temperature measurement of the amorphous alloy core and observed heating of individual coils as a result of the proximity e ect at rated power ( b ). Energies 2020 , 13 , x FOR PEER REVIEW
Figure 9 Primary MFT current i TR (25 A/div) and drain-source voltage v DS (100 V/div) of the SiC MOSFET of the DAB DC-DC converter operating with 20 kHz switching frequency and the DPS modulation (20 µs/div) ( a ); temperature measurement of the amorphous alloy core and observed heating of individual coils as a result of the proximity effect at rated power ( b ). Figure 9. Primary MFT current i TR (25 A / div) and drain-source voltage v DS (100 V / div) of the SiC MOSFET of the DAB DC-DC converter operating with 20 kHz switching frequency and the DPS modulation (20 µ s / div) ( a ); temperature measurement of the amorphous alloy core and observed heating of individual coils as a result of the proximity e ect at rated power ( b ). Energies 2020 , 13 , x FOR PEER REVIEWCC-BY · From the PDF
Image 10
CC-BY · From the PDF
Figure 11 Temperature measurement of the second developed MFT with split windings at power of Figure 11. Temperature measurement of the second developed MFT with split windings at power of 45 kW without forced cooling.
Figure 11 Temperature measurement of the second developed MFT with split windings at power of Figure 11. Temperature measurement of the second developed MFT with split windings at power of 45 kW without forced cooling.CC-BY · From the PDF
Figure 12 The overall control scheme for the DC PETT input stage. Figure 12. The overall control scheme for the DC PETT input stage.
Figure 12 The overall control scheme for the DC PETT input stage. Figure 12. The overall control scheme for the DC PETT input stage.CC-BY · From the PDF
Figure 13 The single DAB DC-DC converter and its control system. Figure 13. The single DAB DC-DC converter and its control system.
Figure 13 The single DAB DC-DC converter and its control system. Figure 13. The single DAB DC-DC converter and its control system.CC-BY · From the PDF
Figure 14 Measured waveforms of the DAB DC-DC converter with the second MFT prototype: primary transformer current i TR_pri (1), 25 A/div; primary voltage v TR_pri (2), 500 V/div; secondary voltage v TR_sec (3), 500 V/div at the rated load. Time scale 4 µs/div. ( a ) and 1 µs/div. ( b ). Figure 14. Measured waveforms of the DAB DC-DC converter with the second MFT prototype: primary transformer current i TR_pri (1), 25 A / div; primary voltage v TR_pri (2), 500 V / div; secondary voltage v TR_sec (3), 500 V / div at the rated load. Time scale 4 µ s / div. ( a ) and 1 µ s / div. ( b ).
Figure 14 Measured waveforms of the DAB DC-DC converter with the second MFT prototype: primary transformer current i TR_pri (1), 25 A/div; primary voltage v TR_pri (2), 500 V/div; secondary voltage v TR_sec (3), 500 V/div at the rated load. Time scale 4 µs/div. ( a ) and 1 µs/div. ( b ). Figure 14. Measured waveforms of the DAB DC-DC converter with the second MFT prototype: primary transformer current i TR_pri (1), 25 A / div; primary voltage v TR_pri (2), 500 V / div; secondary voltage v TR_sec (3), 500 V / div at the rated load. Time scale 4 µ s / div. ( a ) and 1 µ s / div. ( b ).CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Figure 16 Measured efficiency versus output power of the DAB DC-DC converter with the second MFT prototype. Figure 16. Measured e ciency versus output power of the DAB DC-DC converter with the second MFT prototype.
Figure 16 Measured efficiency versus output power of the DAB DC-DC converter with the second MFT prototype. Figure 16. Measured e ciency versus output power of the DAB DC-DC converter with the second MFT prototype.CC-BY · From the PDF
Figure 17 The basic structure of the multiscalar model based control system for the traction motor. Figure 17. The basic structure of the multiscalar model based control system for the traction motor.
Figure 17 The basic structure of the multiscalar model based control system for the traction motor. Figure 17. The basic structure of the multiscalar model based control system for the traction motor.CC-BY · From the PDF
Figure 18 MASTER controller board consisting of main ADSP-21363 based control card and the auxiliary STM32F407IGT6 Arm Cortex based control card ( a ); one of nine STM32F407IGT6 Arm Cortex based SLAVE controller boards controlling nine 4QC-DAB-DC/AC power electronic cells ( b ). Figure 18. MASTER controller board consisting of main ADSP-21363 based control card and the auxiliary STM32F407IGT6 Arm Cortex based control card ( a ); one of nine STM32F407IGT6 Arm Cortex based SLAVE controller boards controlling nine 4QC-DAB-DC / AC power electronic cells ( b ).
Figure 18 MASTER controller board consisting of main ADSP-21363 based control card and the auxiliary STM32F407IGT6 Arm Cortex based control card ( a ); one of nine STM32F407IGT6 Arm Cortex based SLAVE controller boards controlling nine 4QC-DAB-DC/AC power electronic cells ( b ). Figure 18. MASTER controller board consisting of main ADSP-21363 based control card and the auxiliary STM32F407IGT6 Arm Cortex based control card ( a ); one of nine STM32F407IGT6 Arm Cortex based SLAVE controller boards controlling nine 4QC-DAB-DC / AC power electronic cells ( b ).CC-BY · From the PDF
Figure 19 The route of test runs with a length of 600 m on the Bydgoszcz-Towarowa railway siding. Figure 19. The route of test runs with a length of 600 m on the Bydgoszcz-Towarowa railway siding.
Figure 19 The route of test runs with a length of 600 m on the Bydgoszcz-Towarowa railway siding. Figure 19. The route of test runs with a length of 600 m on the Bydgoszcz-Towarowa railway siding.CC-BY · From the PDF
Figure 20 Track test results: Recorded waveforms during start-up of the train with the DC PETT based asynchronous traction drive to a speed of 45 km/h and immediate braking. Top to bottom: (1) train speed; (2) traction motor torque; (3) DC PETT input power; (4) DC PETT input current; (5) traction DC voltage; (6) primary DC bus voltage of a single 4QC-DAB-DC/AC power electronic cell. Figure 20. Track test results: Recorded waveforms during start-up of the train with the DC PETT based asynchronous traction drive to a speed of 45 km / h and immediate braking. Top to bottom: (1) train speed; (2) traction motor torque; (3) DC PETT input power; (4) DC PETT input current; (5) traction DC voltage; (6) primary DC bus voltage of a single 4QC-DAB-DC / AC power electronic cell.
Figure 20 Track test results: Recorded waveforms during start-up of the train with the DC PETT based asynchronous traction drive to a speed of 45 km/h and immediate braking. Top to bottom: (1) train speed; (2) traction motor torque; (3) DC PETT input power; (4) DC PETT input current; (5) traction DC voltage; (6) primary DC bus voltage of a single 4QC-DAB-DC/AC power electronic cell. Figure 20. Track test results: Recorded waveforms during start-up of the train with the DC PETT based asynchronous traction drive to a speed of 45 km / h and immediate braking. Top to bottom: (1) train speed; (2) traction motor torque; (3) DC PETT input power; (4) DC PETT input current; (5) traction DC voltage; (6) primary DC bus voltage of a single 4QC-DAB-DC / AC power electronic cell.CC-BY · From the PDF
Figure 21 Traction motor stator current and output PWM voltage waveforms obtained during three operation modes of the DC PETT: start-up and acceleration mode ( a ); braking ( b ); phase voltage and Figure 21. Traction motor stator current and output PWM voltage waveforms obtained during three operation modes of the DC PETT: start-up and acceleration mode ( a ); braking ( b ); phase voltage and phase current of the traction motor steady-state operation ( c ).
Figure 21 Traction motor stator current and output PWM voltage waveforms obtained during three operation modes of the DC PETT: start-up and acceleration mode ( a ); braking ( b ); phase voltage and Figure 21. Traction motor stator current and output PWM voltage waveforms obtained during three operation modes of the DC PETT: start-up and acceleration mode ( a ); braking ( b ); phase voltage and phase current of the traction motor steady-state operation ( c ).CC-BY · From the PDF
Figure 22 Measured efficiency versus output power of the three power stages and the entire 3kV DC PETT prototype. Figure 22. Measured e ciency versus output power of the three power stages and the entire 3kV DC PETT prototype.
Figure 22 Measured efficiency versus output power of the three power stages and the entire 3kV DC PETT prototype. Figure 22. Measured e ciency versus output power of the three power stages and the entire 3kV DC PETT prototype.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 6

  1. Brenna, M.; Foiadelli, F.; Zaninelli, D. Electrical Railway Transportation Systems; IEEE Press Series on Power Engineering; John Wiley & Sons, Inc.: Hoboken, NJ, USA, 2018.
  2. Dangl, F.; Neudorfer, H. Impact of Additional Losses due to Inverter Supply on the Thermal Behaviour of Induction Machines for Traction Drives. Elektrotechnik Inf. 2016, 1, 27-35.
  3. Soltau, N.; Wiesner, E.; Hatori, K.; Uemura, H. 3.3 kV Full SiC MOSFETs-Towards High-Performance Traction Inverters. Bodos Power Syst. 2018, 1, 22-24.
  4. Morel, F.; Stackler, C.; Ladoux, P.; Fouineau, A.; Wallart, F.; Evans, N.; Dworakowski, P. Power electronic traction transformers in 25 kV/50 Hz systems: Optimisation of DC/DC Isolated Converters with 3.3 kV SiC MOSFETs. In Proceedings of the International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management (PCIM Europe 2019), Nurnberg, Germany, 7-9 May 2019; pp. 1-9.
  5. Doebbelin, R.; Teichert, C.; Benecke, M.; Lindemann, A. Computerized calculation of leakage inductance values of transformers. Piers Online 2009, 5, 721-726.
  6. Wilamowski, B.M.; Irwin, J.D. (Eds.) The Industrial Electronics Handbook. Power Electronics and Motor Drives, 2nd ed.; CRC Press, Taylor & Francis Group: Boca Raton, FL, USA, 2011.

Cited by

Metadata

Authors
Adamowicz, M., & Szewczyk, J.
Affiliations
  • Gdańsk University of Technology (PL)
  • MMB Drives Ltd., Maszynowa 26, 80-298 Gdańsk, Poland
Corresponding author
Adamowicz, Marek
Venue
Energies
Publisher
MDPI AG
Published
2020-10-24
Volume
13
Issue
21
Pages
5573
ISSN
1996-1073 (ISSN-L)
OpenAlex
W3094166223
Cited by
24
References
35
Citations by year
2026: 3 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 1
FWCI
0.94
Type
journal article
Language
en
Open access
Locations
  • Energies (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Narodowe Centrum Badań i Rozwoju (POIR.01.02.00-00-0193/16-00)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Social Sciences › Transportation › Railway Systems and Energy Efficiency
Keywords
silicon carbide, electric multiple units, SiC transistors, regional trains

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.