SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
Open accessThe DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Abstract
The design of rolling stock plays a key role in the attractiveness of the rail transport. Train design must strictly meet the requirements of rail operators to ensure high quality and cost-effective services. Semiconductor power devices made from silicon carbide (SiC) have reached a level of technology enabling their widespread use in traction power converters. SiC transistors offering energy savings, quieter operation, improved reliability and reduced maintenance costs have become the choice for the next-generation railway power converters and are quickly replacing the IGBT technology which has been used for decades. The paper describes the design and development of a novel SiC-based DC power electronic traction transformer (PETT) intended for electric multiple units (EMUs) operated in 3 kV DC rail traction. The details related to the 0.5 MVA peak power medium voltage prototype, including the electrical design of the main building blocks are presented in the first part of the paper. The second part deals with the implementation of the developed SiC-based DC PETT into a regional train operating on a 3 kV DC traction system. The experimental results obtained during the testing are presented to demonstrate the performance of the developed 3 kV DC PETT prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In Adamowicz and Szewczyk [9], the 3 kV DC/DC SST, including the traction inverter, was developed. This SST is intended for 3 kV DC rail traction in Poland. However, although a direct comparison is difficult due to the absence of the AC/DC conversion stage, efficiency is relatively low at peak 96.5%.”
From Development of medium voltage single‐phase solid‐state transformer for high‐speed railway vehicles: Reduced scale verification results (2025) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567 · cited 1×
“The working principle of the DAB DC-DC converter lies in the phase-shift δ, introduced between the rectangular AC voltages generated by the two active bridges [26,28].”
BackgroundPower Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 8×
“The use of MFTs developed in [19] allows for weight reduction and power density improvement (0.”
BackgroundMethodInfluentialLeibl, M., Ortiz, G., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2623679 · Cited by 306 · cited 1×
“Achieving the desired MFT design that will maximize power density and efficiency while maintaining space and weight restrictions requires a complicated optimization procedure [25].”
BackgroundDas, M. K., Capell, C., Grider, D. E., Leslie, S., Ostop, J., Raju, R., Schutten, M., Nasadoski, J., & Hefner, A. (2011) · 2011 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2011.6064129 · Cited by 226
Nonlinear Control of Induction Motor
Krzemiński, Z. (1987) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)55396-3 · Cited by 223 · cited 2×
“The multiscalar model based control [38,39] has been used to control the torque and excitation of the traction motor.”
MethodRonanki, D., Singh, S. A., & Williamson, S. S. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2703583 · Cited by 198 · cited 3×
“Conventional line frequency transformers (LFTs) used in AC EMUs occupy up to 12% of the weight of rail vehicle and a corresponding part of the train space [2].”
BackgroundOptimum Number of Cascaded Cells for High-Power Medium-Voltage AC–DC Converters
Huber, J. E., & Kolar, J. W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2605702 · Cited by 191 · cited 3×
“, [20,21], cascaded cells converter systems, such as the CHB topology, are a very attractive solution to interface power electronic systems to MVAFigure 4.”
BackgroundPan, J., Ke, Z., Sabbagh, M. A., Li, H., Potty, K. A., Perdikakis, W., Na, R., Zhang, J., Wang, J., & Xu, L. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978657 · Cited by 98 · cited 4×
“As can be seen from Figure 22, the three-phase seven-level CHB traction inverter (7L CHB), considered separately, ch racterizes peak efficiency around 99%, which is comparable to the corresponding SiC based MV multilevel CHB inverters c nstructed from low-voltage SiC MOSFET transistors, presented in the literature [22…”
BackgroundInfluentialMultiphysical Characterization of Medium-Frequency Power Electronic Transformers
Villar, I. (2010) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-4622 · Cited by 86 · cited 13×
“The performance of DAB DC-DC converters and the entire DC PETT system is strongly affected by the design of the MFTs [26].”
BackgroundMethodInfluentialEfficiency Optimizing Control of Induction Motor Using Natural Variables
Dong, G., & Ojo, O. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885117 · Cited by 84 · cited 2×
“the arbitrary chosen efficiency optimizing formulation, which ensures the improved efficiency of the traction drive [40].”
BackgroundPerformance comparison of SiC Schottky diodes and silicon ultra fast recovery diodes
Adamowicz, M., Giziewski, S., Pietryka, J., & Krzemiński, Z. (2011) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2011.5942222 · Cited by 65 · cited 2×
“These loop inductances together with SiC MOSFET output capacitance create a resonant tank, which is the source of unwanted EMI emissions [23,24].”
BackgroundSelf-citationVillar, I., Mir, L., Etxeberria-Otadui, I., Colmenero, J., Agirre, X., & Nieva, T. (2012) · 2012 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342754 · Cited by 64
Haneda, R., & Akagi, H. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975256 · Cited by 62 · cited 1×
“However, in some justified cases, the use of additional auxiliary inductance may be unavoidable [33].”
BackgroundRufer, A., Schibli, N., Chabert, C., & Zimmermann, C. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.816191 · Cited by 60 · cited 3×
“The DC PETT described in [14] provides a higher quality of drive operation during DC voltage disturbances which normally occur in 3 kV DC traction, than conventional propulsion systems with two-level and three-level inverters.”
BackgroundInfluentialPeng, S., & Biela, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2636572 · Cited by 60
Taking into account all the parasitic effects in the design of magnetic components
Prieto, R., Cobos, J. A., García, O., Alou, P., & Uceda, J. (2002) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1998.647721 · Cited by 26 · cited 1×
“Split windings construction enables obtaining a higher leakage flux density and correspondingly higher leakage inductance compared to the cylindrical transformer with the same number of turns [35].”
BackgroundDesign Challenges of SiC Devices for Low- and Medium-Voltage DC-DC Converters
Engelmann, G., Sewergin, A., Neubert, M., & Doncker, R. W. D. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507485 · Cited by 26
Development of Rolling Stock Inverters Using SiC
Ishikawa, K., Kiyoshi, T., Sakai, T., Shinji, S., & Takayoshi, N. (2017) · Cited by 23
Modeling and Optimization of Bidirectional Dual Active Bridge AC-DC Converter Topologies
Everts, J. (2014) · TU/e Research Portal · Cited by 23
Solid-State Transformers in Locomotives Fed through AC Lines: A Review and Future Developments
Farnesi, S., Marchesoni, M., Passalacqua, M., & Vaccaro, L. (2019) · Energies · doi:10.3390/en12244711 · Cited by 22
Methods of calculating leakage inductance of transformer windings
Kantor, V. V. (2009) · Russian Electrical Engineering · doi:10.3103/s1068371209040105 · Cited by 15 · cited 3×
“The leakage inductance of two uniform, concentric windings, of equal height, for which the leakage field inside the windings can be assumed to be axial, can be determined from Rogowski approximation method [34] using the mean length per turn for the whole arrangement of coils lm:”
BackgroundMethodInfluentialLindahl, M., Velander, E., Johansson, M. H., Blomberg, A., & Nee, H. (2018) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2018.8604975 · Cited by 15 · cited 1×
“The most obvious benefit of SiC metal-oxide semiconductor field-effect transistors (MOSFETs) compared to IGBTs is a significant reduction in switching losses, up to 55%, and total power losses, up to 80% [6].”
BackgroundPower Electronics Technologies for Locomotives
Bakran, M., & Eckel, H.-G. (2007) · Power Conversion Conference · doi:10.1109/pccon.2007.373142 · Cited by 13 · cited 1×
“In the case of a drive inverter for rolling stock for 3 kV DC traction, it would be difficult to find any significant changes in the construction and control technology in the last decades [2,9,10].”
BackgroundOptimal sizing of a power electronic traction transformer for railway applications
Stackler, C., Morel, F., Ladoux, P., Fouineau, A., Wallart, F., & Evans, N. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591686 · Cited by 13 · cited 1×
“The works [15] and [16] present the method of optimal sizing of 25 kV/50 Hz-type PETTs using 3.”
MethodInput Filter for a Power Electronics Transformer in a Railway Traction Application
Aceiton, R., Weber, J., & Bernet, S. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2821621 · Cited by 12 · cited 2×
“The results presented in [13] have shown that the use of a passively-damped LCL filter for the input-side results in a significantly lighter solution, compared to a single-pole type (single inductor) reported in most cases.”
BackgroundResultSteczek, M., Szeląg, A., & Chatterjee, D. (2017) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.1515/bpasts-2017-0071 · Cited by 11
SiC-hybrid based railway inverter for metro application with 3.3kV low inductance power modules
Rujas, A., Lopez-Martin, V. M., Villar, I., Nieva, T., & Larzabal, I. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912684 · Cited by 11
Lewicki, A., & Morawiec, M. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5886 · Cited by 10 · cited 2×
“At each switching sequence only one H-bridge per phase provides a modulated output voltage, while the others are negatively/positively connected or bypassed [37].”
BackgroundMethodReliability and availability performances of a universal and flexible power management system
Magro, M. C., & Savio, S. (2010) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2010.5637723 · Cited by 9 · cited 3×
“, [20,21], cascaded cells converter systems, such as the CHB topology, are a very attractive solution to interface power electronic systems to MVAFigure 4.”
BackgroundSaeed, M., Rogina, M. R., Rodrı́guez, A., Arias, M., & Briz, F. (2020) · Energies · doi:10.3390/en13051198 · Cited by 9
Adamowicz, M. (2014) · Acta Energetica Power Engineering Quarterly · doi:10.12736/issn.2300-3022.2014401 · Cited by 7
Self-citationMüllner, F., Neudorfer, H., & Schmidt, E. (2011) · International Aegean Conference on Electrical Machines and Power Electronics · doi:10.1109/acemp.2011.6490634 · Cited by 3
J-F.Tremong, J.-F. T., Vulturescu, B., & Chamaret, A.-P. C. (2018) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1441022 · Cited by 1
Innovative Railway Traction System
Falco, M., Desportes, G., & Piton, M. (2018) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1451381 · Cited by 1
Research works printed but not linked: 6
- Brenna, M.; Foiadelli, F.; Zaninelli, D. Electrical Railway Transportation Systems; IEEE Press Series on Power Engineering; John Wiley & Sons, Inc.: Hoboken, NJ, USA, 2018.
- Dangl, F.; Neudorfer, H. Impact of Additional Losses due to Inverter Supply on the Thermal Behaviour of Induction Machines for Traction Drives. Elektrotechnik Inf. 2016, 1, 27-35.
- Soltau, N.; Wiesner, E.; Hatori, K.; Uemura, H. 3.3 kV Full SiC MOSFETs-Towards High-Performance Traction Inverters. Bodos Power Syst. 2018, 1, 22-24.
- Morel, F.; Stackler, C.; Ladoux, P.; Fouineau, A.; Wallart, F.; Evans, N.; Dworakowski, P. Power electronic traction transformers in 25 kV/50 Hz systems: Optimisation of DC/DC Isolated Converters with 3.3 kV SiC MOSFETs. In Proceedings of the International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management (PCIM Europe 2019), Nurnberg, Germany, 7-9 May 2019; pp. 1-9.
- Doebbelin, R.; Teichert, C.; Benecke, M.; Lindemann, A. Computerized calculation of leakage inductance values of transformers. Piers Online 2009, 5, 721-726.
- Wilamowski, B.M.; Irwin, J.D. (Eds.) The Industrial Electronics Handbook. Power Electronics and Motor Drives, 2nd ed.; CRC Press, Taylor & Francis Group: Boca Raton, FL, USA, 2011.
Cited by
A Review on Power Electronics Technologies for Power Quality Improvement
Afonso, J. L., Tanta, M., Pinto, J. G. O., Monteiro, L. F. C., Machado, L., Sousa, T. J. C., & Monteiro, V. (2021) · Energies · doi:10.3390/en14248585 · Cited by 119
Solid State Transformers: A Critical Review of Projects with Relevant Prototypes and Demonstrators
Cervero, D., Fotopoulou, M. C., Muñoz-Cruzado-Alba, J., Rakopoulos, D. C., Stergiopoulos, F., Nikolopoulos, N., Voutetakis, S. S., & Sanz, J. F. (2023) · Electronics · doi:10.3390/electronics12040931 · Cited by 70
Ravindran, R., & Massoud, A. M. (2025) · Microelectronic Engineering · doi:10.1016/j.mee.2025.112348 · Cited by 44
A Review of Wide Bandgap Semiconductors: Insights into SiC, IGZO, and Their Defect Characteristics
Shangguan, Q., Lv, Y., & Jiang, C. (2024) · Nanomaterials · doi:10.3390/nano14201679 · Cited by 42
Somkun, S., Sato, T., Chunkag, V., Pannawan, A., Nunocha, P., & Suriwong, T. (2021) · Energies · doi:10.3390/en14092407 · Cited by 33
“DAB DC-DC converters are normally applied in solid-state transformers (SSTs) for photovoltaic and wind energy systems [2–4], on-board battery chargers in electric vehicles [5], railway traction systems [6,7], electric aircraft applications [8], and grid energy storage systems [9–12].”
Background
Metadata
- Authors
- Adamowicz, M., & Szewczyk, J.
- Affiliations
- Gdańsk University of Technology (PL)
- MMB Drives Ltd., Maszynowa 26, 80-298 Gdańsk, Poland
- Corresponding author
- Adamowicz, Marek
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2020-10-24
- Volume
- 13
- Issue
- 21
- Pages
- 5573
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3094166223
- Cited by
- 24
- References
- 35
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowe Centrum Badań i Rozwoju (POIR.01.02.00-00-0193/16-00)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Social Sciences › Transportation › Railway Systems and Energy Efficiency
- Keywords
- silicon carbide, electric multiple units, SiC transistors, regional trains
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.