Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents
Open accessThe DOI matches its Crossref record; 49 of the 50 references it cites were found in a registry or an index.
Abstract
Stator winding faults are one of the most common faults of permanent magnet synchronous motors (PMSMs), and searching for methods to efficiently detect this type of fault and at an early stage of damage is still an ongoing, important topic. This paper deals with the selected methods for detecting stator winding faults (short-circuits) of a permanent magnet synchronous motor, which are based on the analysis of the stator phase current signal. These methods were experimentally verified and their effectiveness was carefully compared. The article presents the results of experimental studies obtained from the spectral analysis of the stator phase current, stator phase current envelope, and the discrete wavelet transform. The original fault indicators (FIs) based on the observation of the symptoms of stator winding fault were distinguished using the aforementioned methods, which clearly show which symptom is most sensitive to the incipient fault of the stator winding of PMSMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Greater sensitivity of this component to the stator winding fault compared to the FFT of the stator phase current is also emphasized.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [43]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [43]
The cited source says what the claim attributes to it.
In the citing paper
“In all of these papers, the Authors conclude that the increase of the 2fs component amplitude in the stator phase current space vector module spectrum is a symptom of a stator winding fault.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [43]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Application of wavelet transform and its advantages compared to fourier transform
Sifuzzaman, M., Islam, M. R., & Ali, M. Z. (2014) · Cited by 383
Rosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Kim, K.-H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2060463 · Cited by 184
Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system
Zidani, F., El Hachemi Benbouzid, M., Diallo, D., & Nait-Said, M. S. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.815832 · Cited by 183
Hang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 150
Reliable Detection of Stator Interturn Faults of Very Low Severity Level in Induction Motors
Gyftakis, K. N., & Cardoso, A. J. M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2978710 · Cited by 142
Wavelet transform and signal denoising using Wavelet method
Dautov, C. P., & Özerdem, M. S. (2018) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2018.8404418 · Cited by 129
Skowron, M., Orłowska-Kowalska, T., Wolkiewicz, M., & Kowalski, C. T. (2020) · Energies · doi:10.3390/en13061475 · Cited by 125
Self-citation
Research works printed but not linked: 1
- Huang, S.; Aggarwal, A.; Strangas, E.; Li, K.; Niu, F.; Huang, X. Robust Stator Winding Faults Detection in PMSMs with Respect to Current Controller Bandwith. IEEE Trans. Power Electron. 2020, 10, 1109.
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Self-citationFault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 139
Pietrzak, P., Wolkiewicz, M., & Orłowska-Kowalska, T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3189076 · Cited by 95
Self-citationPietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
Self-citationMethods of Condition Monitoring and Fault Detection for Electrical Machines
Kudelina, K., Asad, B., Vaimann, T., Rassõlkin, A., Kallaste, A., & Khang, H. V. (2021) · Energies · doi:10.3390/en14227459 · Cited by 66
Metadata
- Authors
- Pietrzak, P., & Wolkiewicz, M.
- Affiliations
- Department of Electrical Machines, Drives and Measurements, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
- Wrocław University of Science and Technology (PL)
- Corresponding author
- Wolkiewicz, Marcin
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2021-03-15
- Volume
- 14
- Issue
- 6
- Pages
- 1630
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3138139515
- Cited by
- 40
- References
- 50
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 10 · 2021: 6
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Narodowym Centrum Nauki (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, short-circuit faults, fault indicators, spectral analysis, discrete wavelet transform, incipient fault diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents. https://app.cochat.ai/papers/10.3390/en14061630
- The paper
- Pietrzak, P., & Wolkiewicz, M. (2021). Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents. Energies. https://doi.org/10.3390/en14061630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.