Distributed Generation and Renewable Energy Integration into the Grid: Prerequisites, Push Factors, Practical Options, Issues and Merits
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Power system operators are in search of proven solutions to improve the penetration levels of distributed generators (DGs) in the grid while minimizing cost. This transition is driven, among others, by global climate concerns, the growing power demand, the need for greater flexibility, the ageing grid infrastructure and the need to diversify sources of energy production. Distributed renewables would not easily substitute the conventional electric grid system, perhaps because the latter is a well-established technology and it would not be prudent to abandon it, while the new distributed renewable energy technologies are generally not adequately developed to support the total load. Thus, it is becoming increasingly necessary to consider sustainable options such as integrating renewable energy sources into the existing power grid. This study is a review that is mainly hinged on distributed generation (DG) classification, the challenges of DG to grid integration, practical options used in DG integration, lessons learned from some countries with successful DG to grid integration, push factors in the growth of DGs and the merits of DG to grid integration. These standpoints of DG to grid interconnection are critical in conducting grid planning and operational studies, which should be conducted in strict observance of aspects such as optimal technology selection, optimal capacity and a suitable connection point of DGs in the network. Therefore, the perspectives highlighted regarding DG can assist power system engineers, developers of DG plants and policymakers in developing a power network that is stable, efficient and reliable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distributed generation: a definition
Ackermann, T., Andersson, G., & Söder, L. (2001) · Electric Power Systems Research · doi:10.1016/s0378-7796(01)00101-8 · Cited by 2,502
Distributed generation: definition, benefits and issues
Pepermans, G., Driesen, J., Haeseldonckx, D., Belmans, R., & D’haeseleer, W. (2005) · Energy Policy · doi:10.1016/j.enpol.2003.10.004 · Cited by 1,592
An Approach to Quantify the Technical Benefits of Distributed Generation
Chiradeja, P., & Ramakumar, R. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827704 · Cited by 715 · cited 1×
“The authors in [19] have suggested some performance indicators to evaluate the benefits of DG units, focusing on voltage profile enhancement, lowering transmission line losses and reducing environmental impact.”
BackgroundMultiobjective Optimization for DG Planning With Load Models
Singh, D., Singh, D., & Verma, K. S. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2009483 · Cited by 553 · cited 1×
“Similar studies using technical indicators were conducted by [20,21] with the addition of line capacity.”
Solar PV Integration Challenges
Katiraei, F., & Aguero, J. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.940579 · Cited by 550 · cited 1×
“While proposing a new approach in assessing the impact of solar-based DG units, the researchers in [76] provided insights into the issue of reverse power flow that can occur during solar PV penetration into the grid.”
BackgroundFang, J., Tang, Y. K., Li, H., & Li, X. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2759256 · Cited by 463 · cited 1×
“This DG unit provides critical services such as running the transportation systems, managing emergency services and providing an internal security system for the county [69].”
BackgroundEffect of Load Models in Distributed Generation Planning
Singh, D., Misra, R. K., & Singh, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907582 · Cited by 434 · cited 1×
“The number and capacity of connected DGs to the network will determine the amount of impact on the power quality; huge and uncontrolled injection of power from these systems could have a negative effect on the power quality [34,36].”
BackgroundZeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Evaluating Distributed Generation Impacts With a Multiobjective Index
Ochoa, L. F., Padilha-Feltrin, A., & Harrison, G. P. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.860262 · Cited by 384 · cited 1×
“Similar studies using technical indicators were conducted by [20,21] with the addition of line capacity.”
Wang, Q., Zhang, C., Ding, Y., Xydis, G., Wang, J., & Østergaard, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.10.048 · Cited by 379 · cited 1×
“Power networks comprising distributed generators around load centers with varying power demands present challenges in terms of the operation and control of the entire system [42].”
Background
Cited by
Sustainable Energy Policies in Developing Countries: A Review of Challenges and Opportunities
Falcone, P. M. (2023) · Energies · doi:10.3390/en16186682 · Cited by 242
Ejuh Che, E., Roland Abeng, K., Iweh, C. D., Tsekouras, G. J., & Fopah-Lele, A. (2025) · Energies · doi:10.3390/en18030689 · Cited by 160
Self-citation
Metadata
- Authors
- Iweh, C. D., Gyamfi, S., Tanyi, E., & Effah-Donyina, E.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2021-08-29
- Volume
- 14
- Issue
- 17
- Pages
- 5375
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3198488256
- Cited by
- 252
- References
- 41
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.