Distributed Generation and Renewable Energy Integration into the Grid: Prerequisites, Push Factors, Practical Options, Issues and Merits
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Power system operators are in search of proven solutions to improve the penetration levels of distributed generators (DGs) in the grid while minimizing cost. This transition is driven, among others, by global climate concerns, the growing power demand, the need for greater flexibility, the ageing grid infrastructure and the need to diversify sources of energy production. Distributed renewables would not easily substitute the conventional electric grid system, perhaps because the latter is a well-established technology and it would not be prudent to abandon it, while the new distributed renewable energy technologies are generally not adequately developed to support the total load. Thus, it is becoming increasingly necessary to consider sustainable options such as integrating renewable energy sources into the existing power grid. This study is a review that is mainly hinged on distributed generation (DG) classification, the challenges of DG to grid integration, practical options used in DG integration, lessons learned from some countries with successful DG to grid integration, push factors in the growth of DGs and the merits of DG to grid integration. These standpoints of DG to grid interconnection are critical in conducting grid planning and operational studies, which should be conducted in strict observance of aspects such as optimal technology selection, optimal capacity and a suitable connection point of DGs in the network. Therefore, the perspectives highlighted regarding DG can assist power system engineers, developers of DG plants and policymakers in developing a power network that is stable, efficient and reliable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distributed generation: a definition
Ackermann, T., Andersson, G., & Söder, L. (2001) · Electric Power Systems Research · doi:10.1016/s0378-7796(01)00101-8 · Cited by 2,502
Distributed generation: definition, benefits and issues
Pepermans, G., Driesen, J., Haeseldonckx, D., Belmans, R., & D’haeseleer, W. (2005) · Energy Policy · doi:10.1016/j.enpol.2003.10.004 · Cited by 1,592
An Approach to Quantify the Technical Benefits of Distributed Generation
Chiradeja, P., & Ramakumar, R. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827704 · Cited by 715 · cited 1×
“The authors in [19] have suggested some performance indicators to evaluate the benefits of DG units, focusing on voltage profile enhancement, lowering transmission line losses and reducing environmental impact.”
BackgroundMultiobjective Optimization for DG Planning With Load Models
Singh, D., Singh, D., & Verma, K. S. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2009483 · Cited by 553 · cited 1×
“Similar studies using technical indicators were conducted by [20,21] with the addition of line capacity.”
Solar PV Integration Challenges
Katiraei, F., & Aguero, J. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.940579 · Cited by 550 · cited 1×
“While proposing a new approach in assessing the impact of solar-based DG units, the researchers in [76] provided insights into the issue of reverse power flow that can occur during solar PV penetration into the grid.”
BackgroundFang, J., Tang, Y. K., Li, H., & Li, X. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2759256 · Cited by 463 · cited 1×
“This DG unit provides critical services such as running the transportation systems, managing emergency services and providing an internal security system for the county [69].”
BackgroundEffect of Load Models in Distributed Generation Planning
Singh, D., Misra, R. K., & Singh, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907582 · Cited by 434 · cited 1×
“The number and capacity of connected DGs to the network will determine the amount of impact on the power quality; huge and uncontrolled injection of power from these systems could have a negative effect on the power quality [34,36].”
BackgroundZeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Evaluating Distributed Generation Impacts With a Multiobjective Index
Ochoa, L. F., Padilha-Feltrin, A., & Harrison, G. P. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.860262 · Cited by 384 · cited 1×
“Similar studies using technical indicators were conducted by [20,21] with the addition of line capacity.”
Wang, Q., Zhang, C., Ding, Y., Xydis, G., Wang, J., & Østergaard, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.10.048 · Cited by 379 · cited 1×
“Power networks comprising distributed generators around load centers with varying power demands present challenges in terms of the operation and control of the entire system [42].”
BackgroundMahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377 · cited 1×
“These voltage fluctuations can further lead to wear and tear in customer electrical appliances and grid equipment [44,45].”
BackgroundDG allocation with application of dynamic programming for loss reduction and reliability improvement
Khalesi, N., Rezaei, N., & Haghifam, M. (2010) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.08.024 · Cited by 371 · cited 1×
“Since power generation from these sources varies with time and location, fluctuations in power output could lead to grid instability and low reliability [46].”
BackgroundNetwork integration of distributed power generation
Dondi, P., Bayoumi, D., Haederli, C., Julian, D., & Suter, M. (2002) · Journal of Power Sources · doi:10.1016/s0378-7753(01)01031-x · Cited by 302 · cited 1×
“According to [25], DGs could also be defined as a small source of power production for storage (usually within the range of less than a kW and tens of MW), which is not a portion of the huge, centralized power network and is located close to the load.”
BackgroundAdil, A. M., & Ko, Y. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.079 · Cited by 279 · cited 2×
“Institutions that are concerned with the protection of the environment have raised concerns regarding the deployment of onshore wind farms, citing noise and aesthetic inconvenience [12].”
BackgroundPaliwal, P., Patidar, N. P., & Nema, R. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.200 · Cited by 271
A review on issues and approaches for microgrid protection
Brearley, B. J., & Prabu, R. R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.047 · Cited by 256 · cited 1×
“For example, DGs that are connected to the grid via an inverter rarely add to the fault current compared to those with a direct connection to the grid, where significant quantities of fault current are added [56].”
BackgroundThe economics of distributed energy generation: A literature review
Allan, G., Eromenko, I., Gilmartin, M., Kockar, I., & McGregor, P. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.064 · Cited by 222 · cited 1×
“together with the growing global electricity consumption, have made DG technologies a sustainable power supply option for the near future [2].”
BackgroundColmenar‐Santos, A., Reino-Rio, C., Borge-Díez, D., & Fernández, E. C. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.023 · Cited by 183 · cited 2×
“Most scholars argue that the suitable location of a DG plant should be at the low-voltage (LV) network where consumers will easily utilize the energy at minimum system losses [13].”
BackgroundLatran, M. B., Teke, A., & Yoldaş, Y. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0531 · Cited by 176 · cited 1×
“Nonetheless, most recent inverters connecting DGs to the power network have the ability to actively shape their current output to an acceptable limit, although some of the injected harmonic currents can distort the voltage profile, which can spread throughout the entire grid [54,55].”
BackgroundZahedi, A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.074 · Cited by 164 · cited 6×
“The obtainable scientific information mainly focuses on general issues influencing the interconnection of distributed energy sources into the power grid [9,11,14].”
BackgroundInfluentialDistribution System Voltage Performance Analysis for High-Penetration Photovoltaics
Liu, E., & Bebic, J. (2008) · doi:10.2172/924648 · Cited by 159
Trichakis, P., Taylor, P. C., Lyons, P. F., & Hair, R. (2008) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20080012 · Cited by 150
The German experience with integrating photovoltaic systems into the low-voltage grids
Bayer, B., Matschoss, P., Thomas, H., & Marian, A. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.11.045 · Cited by 139 · cited 1×
“The voltage drop on these lines is low due to the large cross-section, and, consequently, the reduced voltage drop can significantly increase the hosting capacity of the MV network [41].”
BackgroundPossibilistic Evaluation of Distributed Generations Impacts on Distribution Networks
Soroudi, A., Ehsan, M., Caire, R., & Hadjsaïd, N. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2116810 · Cited by 137 · cited 1×
“[10] argued that distribution networks have been modeled in such a way that they can only manage the flow of power in one direction.”
BackgroundWang, Y., Tang, Y. K., Xu, Y. H., & Xu, Y. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2019.2891072 · Cited by 124 · cited 1×
“These methods are compensation of reactive power through controllers [66,67], the use of storage systems in the network [68–71], control techniques that mimic the operation of synchronous generators [72] and the management of changes in the power demand of thermostatic loads [73,74].”
BackgroundRoy, N. K., & Pota, H. R. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2305282 · Cited by 112 · cited 1×
“Moreover, when the capacity of a DG unit is properly sized, it reduces the capital cost of purchasing equipment in a supposedly oversized system and hence enhances the efficiency of the network [40].”
BackgroundZaheeruddin, & Manas, M. (2015) · Energy Reports · doi:10.1016/j.egyr.2015.06.003 · Cited by 108
Lopes, V. S., & Borges, C. L. T. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2335895 · Cited by 103 · cited 3×
“Lopes and Borges [11] have categorized the challenges of interconnecting DGs into three, namely technical, economic and regula- tory.”
BackgroundSperstad, I. B., & Korpås, M. (2019) · Energies · doi:10.3390/en12071231 · Cited by 99 · cited 1×
“These DG units continuously supplied inhabitants with reliable power years after their recovery from this disaster [70].”
BackgroundDistribution Transformer Loss-of-Life Reduction by Increasing Penetration of Distributed Generation
Agah, S. M. M., & Abyaneh, H. A. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2094210 · Cited by 89
Effective mitigation of the load pulses by controlling the battery/SMES hybrid energy storage system
Bizon, N. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.08.013 · Cited by 89 · cited 1×
“Nonetheless, most recent inverters connecting DGs to the power network have the ability to actively shape their current output to an acceptable limit, although some of the injected harmonic currents can distort the voltage profile, which can spread throughout the entire grid [54,55].”
BackgroundVoltage Variation on Distribution Networks With Distributed Generation: Worst Case Scenario
Mahmud, M. A., Hossain, M. J., & Pota, H. R. (2013) · IEEE Systems Journal · doi:10.1109/jsyst.2013.2265176 · Cited by 72 · cited 1×
“These voltage fluctuations can further lead to wear and tear in customer electrical appliances and grid equipment [44,45].”
BackgroundJain, S. K., Kalambe, S., Agnihotri, G., & Mishra, A. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.024 · Cited by 70 · cited 1×
“Therefore, it is imperative to properly plan DG interconnection to the grid [9,32].”
BackgroundMiranda, I., Silva, N. P., & Leite, H. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2015.2497003 · Cited by 64
Wang, Y., Xu, Y. H., & Tang, Y. K. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113371 · Cited by 60 · cited 1×
“These methods are compensation of reactive power through controllers [66,67], the use of storage systems in the network [68–71], control techniques that mimic the operation of synchronous generators [72] and the management of changes in the power demand of thermostatic loads [73,74].”
BackgroundKhetrapal, P. (2020) · International Journal of Renewable Energy Development · doi:10.14710/ijred.9.2.189-205 · Cited by 37 · cited 7×
“When real power is added or reactive power is utilized in the grid, the voltage waveforms and the load factor of the network are improved [28,85].”
BackgroundInfluentialIntegration of distributed energy sources with electrical power grid
Wasiak, I., & Hanzelka, Z. (2009) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.2478/v10175-010-0132-1 · Cited by 30 · cited 3×
“Distributed renewable systems such as wind turbines, which have power electronic components such as inverters, at some point in the energy conversion process, may introduce current harmonics accompanied by voltage distortion [5].”
BackgroundInfluentialProtection coordination in active distribution grids with IEC 61850
Ishchenko, D., Oudalov, A., & Stoupis, J. (2012) · doi:10.1109/tdc.2012.6281478 · Cited by 28 · cited 1×
“Therefore, DG to grid interconnection will need a protection management system equipped with the ability to support a bidirectional flow of power [57].”
BackgroundEl‐Batawy, S. A., & Morsi, W. G. (2017) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/cjece.2017.2694698 · Cited by 18
Reliability / Security of Distribution System Network under Supporting by Distributed Generation
Eltamaly, A. M., Mohamed, Y. S., El-Sayed, A.-H. M., & Elghaffar, A. N. A. (2019) · Insight - Energy Science · doi:10.18282/i-es.v2i1.181 · Cited by 15
ANALYSIS OF POWER LOSSES DUE TO DISTRIBUTED GENERATION INCREASE ON DISTRIBUTION SYSTEM
Suyono, H., & Hasanah, R. N. (2016) · Jurnal Teknologi · doi:10.11113/jt.v78.8923 · Cited by 12 · cited 1×
“The authors in [75] used DG injection to assess the impact of line losses on a power distribution network.”
Method
Cited by
Sustainable Energy Policies in Developing Countries: A Review of Challenges and Opportunities
Falcone, P. M. (2023) · Energies · doi:10.3390/en16186682 · Cited by 242
Ejuh Che, E., Roland Abeng, K., Iweh, C. D., Tsekouras, G. J., & Fopah-Lele, A. (2025) · Energies · doi:10.3390/en18030689 · Cited by 160
Self-citation
Metadata
- Authors
- Iweh, C. D., Gyamfi, S., Tanyi, E., & Effah-Donyina, E.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2021-08-29
- Volume
- 14
- Issue
- 17
- Pages
- 5375
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3198488256
- Cited by
- 252
- References
- 41
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›