Enabling Optimal Energy Management with Minimal IoT Requirements: A Legacy A/C Case Study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The existing literature on energy saving focuses on large-scale buildings, wherein the energy-saving potential is substantially larger than smaller-scale buildings. However, the research intensity is significantly less for small-scale deployments and their capacities to regulate energy use individually, directly and without depreciating users’ comfort and needs. The current research effort focused on energy saving and user satisfaction, concerning a low-cost—yet technically sophisticated—methodology for controlling conventional residential HVAC units through cheap yet reliable actuation and sensing and auxiliary IoT equipment. The basic ingredients of the proposed experimental methodology involve a conventional A/C unit, an Arduino microcontroller, typical wireless IoT sensors and actuators, a configured graphical environment and a sophisticated, model-free, optimization-and-control algorithm (PCAO) that portrays the ground basis for achieving improved performance results in comparison with conventional methods. The main goal of this study was to produce a system that would adequately and expeditiously achieve energy savings by utilizing minimal hardware/equipment (affordability). The system was designed to be easily expandable in terms of new units or thermal equipment (expandability) and also to be autonomous, requiring zero user interventions at the experimental site (automation). The real-life measurements were collected over two different seasonal periods of the year (winter, summer) and concerned a conventional apartment in the city of Xanthi, Northern Greece, where summers and winters exhibit quite diverse climate characteristics. The final results revealed the increased efficiency of PCAO’s optimization in comparison with a conventional rule-based control strategy (RBC), as concerns energy savings and user satisfaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As highlighted in [168], the success of a BEMS was increasingly judged by its ability to maintain comfort along with efficiency, turning energy management into a dual-objective optimization problem rather than a purely technical one.”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [168]
In the citing paper
“Compared with RBC, summer operation saw 37% lower energy use and 19% cost reduction with negligible comfort loss; winter operation achieved 9.8% energy savings, 10.6% comfort improvement, and 10.5% cost reduction.”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [168]
In the citing paper
“Compared with RBC, summer operation saw 37% lower energy use and 19% cost reduction with negligible comfort loss; winter operation achieved 9.8% energy savings, 10.6% comfort improvement, and 10.5% cost reduction.”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [168]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antonopoulos, I., Robu, V., Couraud, B., Kirli, D., Norbu, S., Kiprakis, A., Flynn, D., Elizondo-Gonzalez, S., & Wattam, S. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109899 · Cited by 656 · cited 1×
“Recent scientific studies have exposed numerous methodologies of and applications for mitigating the environmental impact of buildings’ operation through intelligent energy management [1,2].”
BackgroundAguilar, J., Garces-Jimenez, A., R-Moreno, M. D., & García, R. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111530 · Cited by 278 · cited 1×
“Recent scientific studies have exposed numerous methodologies of and applications for mitigating the environmental impact of buildings’ operation through intelligent energy management [1,2].”
BackgroundAftab, M., Chen, C., Chau, C.-K., & Rahwan, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.07.077 · Cited by 201
Research works printed but not linked: 25
- Michailidis, I., Sangi, R., Michailidis, P., Schil, T., Fuetterer, J., Mueller, D., and Kosmatopoulos, E. (2020). Balancing Energy Efficiency with Indoor Comfort Using Smart Control Agents: A Simulative Case Study. Energies, 13. · DOI
- Rubio, 2002, Economic feasibility of passive ambient comfort in Baja California dwellings, Build. Environ., 37, 993, 10.1016/S0360-1323(01)00085-3 · doi:10.1016/s0360-1323(01)00085-3
- Bhagwat, 2015, Review Paper on Energy Efficiency Technologies for Heating, Ventilation and Air Conditioning (HVAC), Int. J. Sci. Eng. Res., 6, 106
- Tzovaras, D., Giakoumis, D., Vincze, M., and Argyros, A. (2019). Overview of Legacy AC Automation for Energy-Efficient Thermal Comfort Preservation. International Conference on Computer Vision Systems, Proceedings of the 12th International Conference ICVS 2019, Thessaloniki, Greece, 23–25 September 2019, Springer. Lecture Notes in Computer Science. · DOI
- Michailidis, I., Baldi, S., Kosmatopoulos, E., and Boutalis, Y. (2014, January 1–3). Optimization-based Active Techniques for Energy Efficient Building Control Part I: Optimization Algorithms. Proceedings of the International Conference on Buildings Energy Efficiency and Renewable Energy Sources, Kozani, Greece.
- Michailidis, I., Baldi, S., Kosmatopoulos, E., and Boutalis, Y. (2014, January 1–3). Optimization-based Active Techniques for Energy Efficient Building Control Part II: Real-life Experimental Results. Proceedings of the International Conference on Buildings Energy Efficiency and Renewable Energy Sources, Kozani, Greece.
- Michailidis, 2018, Energy-efficient HVAC management using cooperative, self-trained, control agents: A real-life German building case study, Appl. Energy, 211, 113, 10.1016/j.apenergy.2017.11.046 · DOI · Paper page
- Michailidis, 2021, Embedding autonomy in large-scale IoT ecosystems using CAO and L4G-CAO, Discov. Internet Things, 1, 8, 10.1007/s43926-021-00003-w · DOI
- Lawal, Κ., and Rafsanjani, H.N. (2021). Trends, benefits, risks, and challenges of IoT implementation in residential and commercial buildings. Energy Built Environ., in press. · DOI
- 2021, A review of strategies for building energy management system: Model predictive control, demand side management, optimization, and fault detect & diagnosis, J. Build. Eng., 33, 101692, 10.1016/j.jobe.2020.101692 · DOI · Paper page
- Casillas, 2005, A genetic rule weighting and selection process for fuzzy control of heating, ventilating and air conditioning systems, Eng. Appl. Artif. Intell., 18, 279, 10.1016/j.engappai.2004.09.007 · DOI
- Wright, 2002, Optimization of building thermal design and control by multi-criterion genetic algorithm, Energy Build., 34, 959, 10.1016/S0378-7788(02)00071-3 · DOI
- Pourzeynali, 2007, Active control of high rise building structures using fuzzy logic and genetic algorithms, Eng. Struct., 29, 346, 10.1016/j.engstruct.2006.04.015 · DOI · Paper page
- Moon, 2011, Comparative study of artificial intelligence-based building thermal control methods—Application of fuzzy, adaptive neuro-fuzzy inference system, and artificial neural network, Appl. Therm. Eng., 31, 2422, 10.1016/j.applthermaleng.2011.04.006 · DOI
- Liu, 2011, A rapid calibration procedure and case study for simplified simulation models of commonly used HVAC systems, Build. Environ., 46, 409, 10.1016/j.buildenv.2010.08.002 · doi:10.1016/j.buildenv.2010.08.002
- Youssef, A., Caballero, N., and Aerts, J.-M. (2019). Model-based monitoring of occupant’s thermal state for adaptive HVAC predictive controlling. Processes, 7. · DOI
- Dai, 2017, Machine learning approaches to predict thermal demands using skin temperatures: Steady-state conditions, Build. Environ., 114, 1, 10.1016/j.buildenv.2016.12.005 · DOI · Paper page
- Ma, 2012, Model predictive control for the operation of building cooling systems, IEEE Trans. Control Syst. Technol., 20, 796, 10.1109/TCST.2011.2124461 · DOI · Paper page
- Sira-Ramírez, H., Luviano-Juárez, A., Ramírez-Neria, M., and Zurita-Bustamante, E.W. (2017). Active Disturbance Rejection Control of Dynamic Systems: A Flatness Based Approach, Elsevier.
- Michailidis, 2016, Automated control calibration exploiting exogenous environment energy: An Israeli commercial building case study, Energy Build., 128, 473, 10.1016/j.enbuild.2016.06.035 · DOI
- Baldi, 2015, Model-based and model-free “plug-and-play” building energy efficient control, Appl. Energy, 154, 829, 10.1016/j.apenergy.2015.05.081 · DOI
- Fanger, 1967, Calculation of Thermal Comfort: Introduction of a Basic Comfort Equation, ASHRAE Trans., 73, III4.1
- Kosmatopoulos, E.B., Michailidis, I., Korkas, C.D., and Ravanis, C. (2015, January 15–17). Local4Global adaptive optimization and control for system-of-systems. Proceedings of the 2015 European Control Conference (ECC), Linz, Austria. · doi:10.1109/ecc.2015.7331081
- Kurazumi, 2018, The Influence of the Solar Radiation Absorptivity up on the Outdoor Thermal Environment Evaluation Index and the Thermal Sensory Perceptions, Am. J. Clim. Chang., 7, 204, 10.4236/ajcc.2018.72014 · doi:10.4236/ajcc.2018.72014
- Fanger, P.O. (1970). Thermal Comfort. Analysis and Applications in Environmental Engineering, Danish Technical Press.
Cited by
Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications
Michailidis, P., Minelli, F., Michailidis, I., Kurucan, M., Coban, H. H., & Kosmatopoulos, E. (2025) · Energies · doi:10.3390/en19010219 · Cited by 26
Self-citation
Metadata
- Authors
- Michailidis, P., Pelitaris, P., Korkas, C., Michailidis, I., Baldi, S., & Kosmatopoulos, E.
- Affiliations
- Electrical and Computer Engineering Department, Polytechnic School of Xanthi, Democritus University of Thrace, 67100 Xanthi, Greece
- School of Mathematics, Jiulonghu Campus, Southeast University, Nanjijng 211189, China
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2021-11-25
- Volume
- 14
- Issue
- 23
- Pages
- 7910
- ISSN
- 1996-1073
- Cited by
- 16
- References
- 3
- Language
- en
- Funders
- European Commission (768735)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enabling Optimal Energy Management with Minimal IoT Requirements: A Legacy A/C Case Study. https://app.cochat.ai/papers/10.3390/en14237910
- The paper
- Michailidis, P., Pelitaris, P., Korkas, C., Michailidis, I., Baldi, S., & Kosmatopoulos, E. (2021). Enabling Optimal Energy Management with Minimal IoT Requirements: A Legacy A/C Case Study. Energies. https://doi.org/10.3390/en14237910
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.