Review of Methods for Addressing Challenging Issues in the Operation of Protection Devices in Microgrids with Voltages of up to 1 kV That Integrates Distributed Energy Resources
Open accessAbstract
With the large-scale integration of distributed energy resources (DER) into passive distribution networks with voltages of up to 1 kV, these networks are being converted into microgrids. When the topology and operating conditions change, several challenging issues arise related to the functioning of the protection devices (PD) that are in operation. Most DERs, including renewable generators, are integrated into microgrids by means of inverters. In the event of short circuits (SC) in microgrids, these DERs provide a fault current contribution of no more than 1.2–2.0 Irated at the fault location. This makes it difficult to identify the fault location and to carry out the selective disconnection of the faulty element by means of conventional PDs. This article provides an overview of engineering solutions for improving conventional protection schemes that have been historically used in passive distribution networks, as well as for creating modern protection schemes based on innovative principles and new methods. The use of adaptive protections built on decentralized and centralized principles in most cases ensures the reliable protection of microgrids. Modern intelligent electronic devices (IEDs), where protection functions are implemented, rank higher with respect to their technical perfection in terms of reliability, sensitivity, selectivity, and speed performance. The use of multi-agent systems in the implementation of modern protection schemes requires the availability of broadband communication channels, which hinders their use because of the high cost. The combined use of fault current limiters (FCL) and energy storage systems (ESS) allows for the reliable operation of microgrid protections. The use of modern PDs ensures the reliable operation of DERs and power supply to consumers in microgrids, both in the case of grid-connected and islanded operation modes. Since there is no unified concept of designing protection schemes for microgrids with DERs, the choice of specific approaches to the design of protection schemes should be based on the results of a comparative technical and economic analysis of different options.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The participation of the EVCS in managing the operating modes of distribution networks may require the improvement of traditional PR systems.
“In this regard, the participation of the EVCS in managing the operating modes of distribution networks may require the improvement of traditional PR systems [37,38].”
From Determining Volt/Var Characteristics of Electric Vehicle Charging Station Inverters for Voltage Regulation in Distribution Networks (2024) · cites this paper as [37]
The Introduction says changing generation and consumption modes in microgrids alter fault currents and compromise conventional protection devices. Section 4.1 discusses improving conventional protections for microgrids with distributed energy resources. The cited paper does not specifically address EV charging stations (EVCS) participating in distribution-network management, so it supports the general protection concern but not that specific application. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 105 · Cited by 30
Research works printed but not linked: 97
- Filippov, S.P.; Dilman, M.D.; Ilyushin, P.V. Distributed Generation of Electricity and Sustainable Regional Growth. Therm. Eng. 2019, 66, 869-880. [CrossRef] · DOI
- The Hoang, T.; Tuan Tran, Q.; Besanger, Y. An advanced protection scheme for medium-voltage distribution networks containing low-voltage microgrids with high penetration of photovoltaic systems. Int. J. Electr. Power Energy Syst. 2022, 139, 107988. [CrossRef] · DOI
- Ilyushin, P.V.; Pazderin, A.V.; Seit, R.I. Photovoltaic power plants participation in frequency and voltage regulation. In Proceedings of the 17th International Ural Conference on AC Electric Drives (ACED), Yekaterinburg, Russia, 26-30 March 2018. [CrossRef] Energies 2022, 15, 9186 · DOI
- Soshinskaya, M.; Crijns-Graus, W.H.J.; Guerrero, J.M.; Vasquez, J.C. Microgrids: Experiences, barriers and success factors. Renew. Sustain. Energy Rev. 2014, 40, 659-672.
- Shushpanov, I.; Suslov, K.; Ilyushin, P.; Sidorov, D. Towards the flexible distribution networks design using the reliability performance metric. Energies 2021, 14, 6193. [CrossRef] · DOI
- Pasonen, R. Community Microgrid-A Building Block of Finnish Smart Grid. Master's Thesis, Tampere University of Technology, Tampere, Finland, 2020; 119p.
- Ilyushin, P.; Filippov, S.; Kulikov, A.; Suslov, K.; Karamov, D. Specific Features of Operation of Distributed Generation Facilities Based on Gas Reciprocating Units in Internal Power Systems of Industrial Entities. Machines 2022, 10, 693. [CrossRef] · DOI
- Gadanayak, D.A. Protection algorithms of microgrids with inverter interfaced distributed generation units-A review. Electr. Power Syst. Res. 2021, 192, 106986. [CrossRef] · DOI
- Suslov, K.; Shushpanov, I.; Buryanina, N.; Ilyushin, P. Flexible power distribution networks: New opportunities and applications. In Proceedings of the 9th International Conference on Smart Cities and Green ICT Systems, Prague, Czech Republic, 2-4 May 2020; Volume 1, pp. 57-64.
- Pinto, J.O.C.P.; Moreto, M. Protection strategy for fault detection in inverter-dominated low voltage AC microgrid. Electr. Power Syst. Res. 2021, 190, 106572. [CrossRef] · DOI
- Bui, D.M.; Chen, S.L.; Lien, K.Y.; Chang, Y.R.; Lee, Y.; Jiang, J.L. Investigation on transient behaviours of a uni-grounded low-voltage AC microgrid and evaluation on its available fault protection methods: Review and proposals. Renew. Sustain. Energy Rev. 2017, 75, 1417-1452. [CrossRef] · DOI
- Bui, D.M.; Chen, S.L. Fault protection solutions appropriately proposed for ungrounded low-voltage AC microgrids: Review and proposals. Renew. Sustain. Energy Rev. 2017, 75, 1156-1174. [CrossRef] · DOI
- Dehghanian, P.; Wang, B.; Tasdighi, M. New Protection Schemes in Smarter Power Grids with Higher Penetration of Renewable Energy Systems. Pathw. A Smarter Power Syst. 2019, 317-342. [CrossRef] · DOI
- Zheng, D.; Zhang, W.; Netsanet Alemu, S.; Wang, P.; Bitew, G.T.; Wei, D.; Yue, J. Key technical challenges in protection and control of microgrid. Microgrid Prot. Control 2021, 45-56. [CrossRef] · DOI
- Mirsaeidi, S.; Mat Said, D.; Wazir Mustafa, M.; Hafiz Habibuddin, M.; Ghaffari, K. Progress and problems in micro-grid protection schemes. Renew. Sustain. Energy Rev. 2014, 37, 834-839. [CrossRef] · DOI
- Mirsaeidi, S.; Mat Said, D.; Wazir Mustafa, M.; Hafiz Habibuddin, M.; Ghaffari, K. An analytical literature review of the available techniques for the protection of micro-grids. Int. J. Electr. Power Energy Syst. 2014, 58, 300-306. [CrossRef] · DOI
- Sinsel, S.R.; Riemke, R.L.; Hoffmann, V.H. Challenges and solution technologies for the integration of variable renewable energy sources-A review. Renew. Energy 2020, 145, 2271-2285. [CrossRef] · DOI
- Sharma, N.K.; Samantaray, S.R. Issues and challenges in microgrid protection. Microgrid Cyberphys. Syst. 2022, 233-254. [CrossRef] · DOI
- Khalid, H.; Shobole, A. Existing Developments in Adaptive Smart Grid Protection: A Review. Electr. Power Syst. Res. 2021, 191, 106901. [CrossRef] · DOI
- Telukunta, V.; Pradhan, J.; Agrawal, A.; Singh, M.; Srivani, S.G. Protection challenges under bulk penetration of renewable energy resources in power systems: A review. CSEE J. Power Energy Syst. 2017, 3, 365-379. [CrossRef] · DOI
- Li, R. Protection and control technologies of connecting to the grid for distributed power resources. Distrib. Power Resour. 2019, 121-144. [CrossRef] · DOI
- Zheng, D.; Zhang, W.; Alemu, S.N.; Wang, P.; Bitew, G.T.; Wei, D.; Yue, J. Microgrid Protection and Control; Elsevier: Amsterdam, The Netherlands, 2021. [CrossRef] · DOI
- Chandra, A.; Singh, G.K.; Pant, V. Protection of AC microgrid integrated with renewable energy sources-A research review and future trends. Electr. Power Syst. Res. 2021, 193, 107036. [CrossRef] · DOI
- Ilyushin, P.V.; Sukhanov, O.A. The Structure of Emergency-Management Systems of Distribution Networks in Large Cities. Russ. Electr. Eng. 2014, 85, 133-137.
- Majumder, R.; Dewadasa, M.; Ghosh, A.; Ledwich, G.; Zare, F. Control and protection of a microgrid connected to utility through back-to-back converters. Electr. Power Syst. Res. 2011, 81, 1424-1435. [CrossRef] · DOI
- Ilyushin, P.V. Emergency and post-emergency control in the formation of micro-grids. E3S Web Conf. 2017, 25, 02002. [CrossRef] · DOI
- Saad, S.M.; El-Naily, N.; Mohamed, F.A. A new constraint considering maximum PSM of industrial over-current relays to enhance the performance of the optimization techniques for microgrid protection schemes. Sustain. Cities Soc. 2019, 44, 445-457. [CrossRef] · DOI
- Ilyushin, P.V. The analysis of dispersed generation influence on power system automatics settings and function algorithms. In Proceedings of the Methodological Problems in Reliability Study of Large Energy Systems (RSES), Irkutsk, Russia, 2-7 July 2018. [CrossRef] · DOI
- Kulikov, A.L.; Sharygin, M.V.; Ilyushin, P.V. Principles of organization of relay protection in microgrids with distributed power generation sources. Power Technol. Eng. 2020, 53, 611-617. [CrossRef] · DOI
- Sharygin, M.V.; Kulikov, A.L. Statistical methods of mode recognition in relay protection and automation of power supply networks. Power Technol. Eng. 2018, 52, 235-241.
- Ilyushin, P.V. Analysis of the specifics of selecting relay protection and automatic (RPA) equipment in distributed networks with auxiliary low-power generating facilities. Power Technol. Eng. 2018, 51, 713-718. [CrossRef] · DOI
- Kumpulainen, L.; Kauhaniemi, K. Analysis of the impact of distributed generation on automatic reclosing. In Proceedings of the IEEE PES Power Systems Conference and Exposition, 2004, New York, NY, USA, 10-13 October 2004.
- Kulikov, A.L.; Anan'ev, V.V.; Vukolov, V.Y.; Platonov, P.S.; Lachugin, V.F. Modelling of wave processes on power transmission lines to improve the accuracy of fault location. Power Technol. Eng. 2016, 49, 378-385. [CrossRef] · DOI
- Dubey, K.; Sanat; Jena, P. Protection schemes in microgrid. Microgrid Cyberphys. Syst. 2022, 255-276. [CrossRef] · DOI
- Saldarriaga-Zuluaga, S.D.; López-Lezama, J.M.; Muñoz-Galeano, N. Optimal coordination of over-current relays in microgrids considering multiple characteristic curves. Alex. Eng. J. 2021, 60, 2093-2113. [CrossRef] · DOI
- Bogarra, S.; Rubión, X.; Rolán, A.; Córcoles, F.; Pedra, J.; Iglesias, J. Small synchronous machine protection during voltage sags caused by MV grid faults. Electr. Power Syst. Res. 2018, 156, 1-11. [CrossRef] · DOI
- Lei, X.; Duan, J. Wind Farm tie-line protection setting based on adaptive current voltage protection principles. In Proceedings of the 2012 Asia-Pacific Power and Energy Engineering Conference (APPEEC), Shanghai, China, 27-29 March 2012. [CrossRef] · DOI
- Ekanayake, J.B.; Holdsworth, L.; Wu, X.G.; Jenkins, N. Dynamic modeling of doubly fed induction generator wind turbines. IEEE Trans. Power Syst. 2003, 18, 885-895. [CrossRef] · DOI
- Sadeghi, H. A novel method for adaptive distance protection of transmission line connected to wind farms. Electr. Power Energy Syst. 2012, 43, 1376-1382.
- Zhou, C.; Zou, G.; Du, X.; Zang, L. Adaptive current differential protection for active distribution network considering time synchronization error. Int. J. Electr. Power Energy Syst. 2022, 140, 108085. [CrossRef] · DOI
- Oudalov, A.; Fidigatti, A. Adaptive network protection in microgrids. Int. J. Distrib. Energy Resour. 2009, 5, 201-226.
- Eissa, M.M. New protection principle for smart grid with renewable energy sources integration using WiMAX centralized scheduling technology. Int. J. Electr. Power Energy Syst. 2018, 97, 372-384. [CrossRef] · DOI
- Pradhan, J.D.; Hadpe, S.S.; Shriwastava, R.G. Analysis and design of overcurrent protection for grid-connected microgrid with PV generation. Glob. Transit. Proc. 2022, 3, 349-358. [CrossRef] · DOI
- Hallemans, L.; Ravyts, S.; Govaerts, G.; Fekriasl, S.; van Tichelen, P.; Driesen, J. A stepwise methodology for the design and evaluation of protection strategies in LVDC microgrids. Appl. Energy 2022, 310, 118420. [CrossRef] · DOI
- Sotelo, G.G.; Santos, G.; Sass, F.; França, B.W.; Nogueira Dias, D.H.; Fortes, M.Z.; Polasek, A.; de Andrade, R., Jr. A review of superconducting fault current limiters compared with other proven technologies. Superconductivity 2022, 3, 100018. [CrossRef] · DOI
- Habib, H.F.; Lashway, C.R.; Mohammed, O.A. A review of communication failure impacts on adaptive microgrid protection schemes and the use of energy storage as a contingency. IEEE Trans. Ind. Appl. 2018, 54, 1194-1207. [CrossRef] · DOI
- Patnaik, B.; Mishra, M.; Bansal, R.C.; Jena, R.K. AC microgrid protection-A review: Current and future prospective. Appl. Energy 2020, 271, 115210. [CrossRef] · DOI
- Anandan, N.; Sheeba, P.; Sivanesan, S.; Rama, S.; Bhuvaneswari, T.T. Wide area monitoring system for an electrical grid. Energy Procedia 2019, 160, 381-388. [CrossRef] · DOI
- Namdari, F.; Jamali, S.; Crossley, P.A. Power differential based wide area protection. Electr. Power Syst. Res. 2007, 77, 1541-1551. [CrossRef] · DOI
- Mousavi, S.A.E.; Chabanloo, R.M.; Farrokhifar, M.; Pozo, D. Wide area backup protection scheme for distance relays considering the uncertainty of network protection. Electr. Power Syst. Res. 2020, 189, 106651. [CrossRef] · DOI
- Abd el-Ghany, H.A. Optimal PMU allocation for high-sensitivity wide-area backup protection scheme of transmission lines. Electr. Power Syst. Res. 2020, 187, 106485. [CrossRef] · DOI
- Kulikov, A.L.; Loskutov, A.A.; Mitrovic, M. Improvement of the technical excellence of multiparameter relay protection by com- bining the signals of the measuring fault detectors using artificial intelligence methods. In Proceedings of the 2019 International Scientific and Technical Conference Smart Energy Systems (SES), Kazan, Russia, 18-20 September 2019; Volume 124, p. 01039.
- Kaur, G.; Prakash, A.; Rao, K.U. A critical review of Microgrid adaptive protection techniques with distributed generation. Renew. Energy Focus 2021, 39, 99-109. [CrossRef] · DOI
- Demidov, I.; Melgarejo, D.C.; Pinomaa, A.; Ault, L.; Jolkkonen, J.; Leppa, K. IEC-61850 Performance Evaluation in a 5G Cellular Network: UDP and TCP Analysis. In Handbook of Smart Energy Systems; Springer: Cham, Switzerland, 2022; pp. 1-33. [CrossRef] · DOI
- Kumar, S.; Islam, S.M.; Jolfaei, A. Microgrid communications-Protocols and standards. Var. Scalab. Stab. Microgrids 2019, 291-326. [CrossRef] · DOI
- Li, X.; Gan, C.; Liu, Z.; Yan, Y.; Qiao, H.B. Novel WRM-based architecture of hybrid PON featuring online access and full-fiber-fault protection for smart grid. Opt. Commun. 2018, 407, 69-82. [CrossRef] · DOI
- Haddadi, A.; Kocar, I.; Mahseredjian, J.; Karaagac, U.; Farantatos, E. Negative sequence quantities-based protection under inverter-based resources Challenges and impact of the German grid code. Electr. Power Syst. Res. 2020, 188, 106573. [CrossRef] · DOI
- Etingov, D.A.; Zhang, P.; Tang, Z.; Zhou, Y. AI-enabled traveling wave protection for microgrids. Electr. Power Syst. Res. 2022, 210, 108078. [CrossRef] · DOI
- Asl, S.A.F.; Gandomkar, M.; Nikoukar, J. Optimal protection coordination in the micro-grid including inverter-based distributed generations and energy storage system with considering grid-connected and islanded modes. Electr. Power Syst. Res. 2020, 184, 106317. [CrossRef] · DOI
- Dadfar, S.; Gandomkar, M. Augmenting protection coordination index in interconnected distribution electrical grids: Optimal dual characteristic using numerical relays. Int. J. Electr. Power Energy Syst. 2021, 131, 107107. [CrossRef] · DOI
- Alam, M.N. Overcurrent protection of AC microgrids using mixed characteristic curves of relays. Comput. Electr. Eng. 2019, 74, 74-88. [CrossRef] · DOI
- Chakraborty, S.; Das, S.; Sidhu, T.; Siva, A.K. Smart meters for enhancing protection and monitoring functions in emerging distribution systems. Int. J. Electr. Power Energy Syst. 2020, 127, 106626. [CrossRef] · DOI
- Hatata, A.Y.; Ebeid, A.S.; El-Saadawi, M.M. Application of resistive super conductor fault current limiter for protection of grid-connected DGs. Alex. Eng. J. 2018, 57, 4229-4241. [CrossRef] · DOI
- Ferreira, R.R.; Colorado, P.J.; Grilo, A.P.; Teixeira, J.C.; Santos, R.C. Method for identification of grid operating conditions for adaptive overcurrent protection during intentional islanding operation. Int. J. Electr. Power Energy Syst. 2018, 105, 632-641. [CrossRef] · DOI
- Khatua, S.; Mukherjee, V. Adaptive overcurrent protection scheme suitable for station blackout power supply of nuclear power plant operated through an integrated microgrid. Electr. Power Syst. Res. 2020, 192, 106934. [CrossRef] · DOI
- Manditereza, P.T.; Bansal, R.C. Protection of microgrids using voltage-based power differential and sensitivity analysis. Int. J. Electr. Power Energy Syst. 2020, 118, 105756. [CrossRef] · DOI
- Ma, K.; Chen, Z.; Liu, Z.; Leth Bak, C.; Castillo, M. Protection collaborative fault control for power electronic-based power plants during unbalanced grid faults. Int. J. Electr. Power Energy Syst. 2021, 130, 107009. [CrossRef] · DOI
- Mohammadi, S.; Ojaghi, M.; Jalilvand, A.; Shafiee, Q. A pilot-based unit protection scheme for meshed microgrids using apparent resistance estimation. Int. J. Electr. Power Energy Syst. 2021, 126, 106564. [CrossRef] · DOI
- Eissa, M.M.; Mahfouz, M.M.A.; Sowilam, G.M.A. A new developed smart grid protection technique with wind farms based on positive sequence impedances and current angles. Electr. Power Syst. Res. 2020, 178, 106020. [CrossRef] · DOI
- George, S.P.; Ashok, S. Adaptive distance protection for grid-connected wind farms based on optimal quadrilateral characteristics. Comput. Electr. Eng. 2021, 93, 107300. [CrossRef] · DOI
- Jena, S.; Paladhi, S.; Pradhan, A.K. Bus protection in systems with inverter interfaced renewables using composite sequence currents. Int. J. Electr. Power Energy Syst. 2022, 136, 107665. [CrossRef] · DOI
- Mishra, M.; Panigrahi, R.R.; Rout, P.K. A combined mathematical morphology and extreme learning machine techniques-based approach to micro-grid protection. Ain Shams Eng. J. 2019, 10, 307-318. [CrossRef] · DOI
- Langarizadeh, A.; Hasheminejad, S. A new differential algorithm based on S-transform for the micro-grid protection. Electr. Power Syst. Res. 2022, 202, 107590. [CrossRef] · DOI
- Maali Amiri, E.; Vahidi, B. Integrated protection scheme for both operation modes of microgrid using S-Transform. Int. J. Electr. Power Energy Syst. 2020, 121, 106051. [CrossRef] · DOI
- Chaitanya, B.K.; Yadav, A.; Pazoki, M. An improved differential protection scheme for micro-grid using time-frequency transform. Int. J. Electr. Power Energy Syst. 2019, 111, 132-143. [CrossRef] · DOI
- Alvarez de Sotomayor, A.; della Giustina, D.; Massa, G.; Dedè, A.; Ramos, F.; Barbato, A. IEC 61850-based adaptive protection system for the MV distribution smart grid. Sustain. Energy Grids Netw. 2018, 15, 26-33. [CrossRef] · DOI
- Blaabjerg, F.; Yang, Y.; Yang, D.; Wang, X. Distributed Power-Generation Systems and Protection. Proc. IEEE 2017, 105, 1311-1331. [CrossRef] · DOI
- Dagar, A.; Gupta, P.; Niranjan, V. Microgrid protection: A comprehensive review. Renew. Sustain. Energy Rev. 2021, 149, 111401. [CrossRef] · DOI
- Zheng, D.; Zhang, W.; Netsanet Alemu, S.; Wang, P.; Bitew, G.T.; Wei, D.; Yue, J. Protection of microgrids. Microgrid Prot. Control 2021, 121-168. [CrossRef] · DOI
- Barra, P.H.A.; Coury, D.V.; Fernandes, R.A.S. A survey on adaptive protection of microgrids and distribution systems with distributed generators. Renew. Sustain. Energy Rev. 2020, 118, 109524. [CrossRef] · DOI
- Liu, Z.; Su, C.; Høidalen, H.K.; Chen, Z. A multiagent system-based protection and control scheme for distribution system with distributed generation integration. IEEE Trans. Power Deliv. 2017, 32, 536-545.
- Brearley, B.J.; Prabu, R.R. A review on issues and approaches for microgrid protection. Renew. Sustain. Energy Rev. 2017, 67, 988-997. [CrossRef] · DOI
- Ilyushin, P.V.; Kulikov, A.L.; Filippov, S.P. Adaptive algorithm for automated undervoltage protection of industrial power districts with distributed generation facilities. In Proceedings of the 2019 International Russian Automation Conference (RusAutoCon), Sochi, Russia, 8-14 September 2019. [CrossRef] · DOI
- Shobole, A.A.; Wadi, M. Multiagent systems application for the smart grid protection. Renew. Sustain. Energy Rev. 2021, 149, 111352. [CrossRef] · DOI
- Kiani, A.; Fani, B.; Shahgholian, G. A multi-agent solution to multi-thread protection of DG-dominated distribution networks. Int. J. Electr. Power Energy Syst. 2021, 130, 106921. [CrossRef] · DOI
- Rameshrao, A.G.; Koley, E.; Ghosh, S. An optimal sensor location based protection scheme for DER-integrated hybrid AC/DC microgrid with reduced communication delay. Sustain. Energy Grids Netw. 2022, 30, 100680. [CrossRef] · DOI
- Dos Reis, F.B.; Pinto, J.O.C.P.; dos Reis, F.S.; Issicaba, D.; Rolim, J.G. Multi-agent dual strategy based adaptive protection for microgrids. Sustain. Energy Grids Netw. 2021, 27, 100501. [CrossRef] · DOI
- Ghadiri, S.M.E.; Mazlumi, K. Adaptive protection scheme for microgrids based on SOM clustering technique. Appl. Soft Comput. 2020, 88, 106062. [CrossRef] · DOI
- Hussain, A.; Aslam, M.; Arif, S.M. N-version programming-based protection scheme for microgrids: A multi-agent system based approach. Sustain. Energy Grids Netw. 2016, 6, 35-45. [CrossRef] · DOI
- Meyer, G.J.; Lorz, T.; Wehner, R.; Jaeger, J.; Dauer, M.; Krebs, R. Hybrid fuzzy evaluation algorithm for power system protection security assessment. Electr. Power Syst. Res. 2020, 189, 106555. [CrossRef] · DOI
- Gashteroodkhani, O.A.; Majidi, M.; Etezadi-Amoli, M. A combined deep belief network and time-time transform based intelligent protection Scheme for microgrids. Electr. Power Syst. Res. 2020, 182, 106239. [CrossRef] · DOI
- Shen, S.; Lin, D.; Wang, H. An Adaptive Protection Scheme for Distribution Systems with DGs Based on Optimized Thevenin Equivalent Parameters Estimation. IEEE Trans. Power Deliv. 2017, 32, 411-419.
- Saldarriaga-Zuluaga, S.D.; López-Lezama, J.M.; Muñoz-Galeano, N. Adaptive protection coordination scheme in microgrids using directional over-current relays with non-standard characteristics. Heliyon 2021, 7, e06665. [CrossRef] · DOI
- Marín-Quintero, J.; Orozco-Henao, C.; Percybrooks, W.S.; Vélez, J.C.; Montoya, O.D.; Gil-González, W. Toward an adaptive protection scheme in active distribution networks: Intelligent approach fault detector. Appl. Soft Comput. 2020, 98, 106839. [CrossRef] · DOI
- Chakraborty, S.; Das, S. Communication-less protection scheme for AC microgrids using hybrid tripping characteristic. Electr. Power Syst. Res. 2020, 187, 106453. [CrossRef] · DOI
- Marín-Quintero, J.; Orozco-Henao, C.; Velez, J.C.; Bretas, A.S. Micro grids decentralized hybrid data-driven cuckoo search based adaptive protection model. Int. J. Electr. Power Energy Syst. 2021, 130, 106960. [CrossRef] 100. Liu, X.; Cai, Z.; Fan, H.; Yu, M. Experimental studies on the rtEthernet-based centralized fault management system for smart grids. Electr. Power Syst. Res. 2019, 181, 106163. [CrossRef] 101. Adamiak, M.; Apostolov, A.; Begovic, M.; Henville, C.; Martin, K.E.; Michel, G.L.; Phadke, A.G.; Thorp, J.S. Wide Area Protection-Technology and Infrastructures. IEEE Trans. Power Deliv. 2006, 21, 601-609. [CrossRef] 102. Hong, Q.; Kawal, K.; Paladhi, S.; Zhang, G.; Booth, C.; Terzija, V. Wide Area Monitoring, Protection and Control (WAMPAC). Ref. Modul. Mater. Sci. Mater. Eng. 2022, 278-293. [CrossRef] 103. Li, Z.; Wan, Y.; Wu, L.; Cheng, Y.; Weng, H. Study on wide-area protection algorithm based on composite impedance directional principle. Int. J. Electr. Power Energy Syst. 2020, 115, 105518. [CrossRef] 104. · DOI
- Brahma, S.; Kavasseri, R.; Cao, H.; Chaudhuri, N.R.; Alexopoulos, T.; Cui, Y. Real-Time Identification of Dynamic Events in Power Systems Using PMU Data, and Potential Applications-Models, Promises, and Challenges. IEEE Trans. Power Deliv. 2017, 32, 294-301. [CrossRef] 105. Eissa, M.M.; Awadalla, M.H.A. Centralized protection scheme for smart grid integrated with multiple renewable resources using Internet of Energy. Glob. Transit. 2019, 1, 50-60. [CrossRef] 106. Fan, X.; Dudkina, E.; Gambuzza, L.V.; Frasca, M.; Crisostomi, E. A network-based structure-preserving dynamical model for the study of cascading failures in power grids. Electr. Power Syst. Res. 2022, 209, 107987. [CrossRef] 107. Farzinfar, M.; Jazaeri, M. A novel methodology in optimal setting of directional fault current limiter and protection of the MG. Int. J. Electr. Power Energy Syst. 2020, 116, 105564. [CrossRef] 108. Sadeghi, M.; Abasi, M. Optimal placement and sizing of hybrid superconducting fault current limiter for protection coordination restoration of the distribution networks in the presence of simultaneous distributed generation. Electr. Power Syst. Res. 2021, 201, 107541. [CrossRef] 109. Li, J.; Cornelusse, B.; Vanderbemden, P.; Ernst, D. A SC/battery Hybrid Energy Storage System in the Microgrid. Energy Procedia 2017, 142, 3697-3702. [CrossRef] 110. Adewole, A.C.; Rajapakse, A.D.; Ouellette, D.; Forsyth, P. Protection of active distribution networks incorporating microgrids with multi-technology distributed energy resources. Electr. Power Syst. Res. 2022, 202, 107575. [CrossRef] · DOI
- Authors
- Ilyushin, P., Volnyi, V., Suslov, K., & Filippov, S.
- Affiliations
- Russian Academy of Sciences (RU)
- Moscow Power Engineering Institute (RU)
- Corresponding author
- Ilyushin, Pavel
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2022-12-04
- Volume
- 15
- Issue
- 23
- Pages
- 9186
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W4311626304
- Cited by
- 30
- References
- 105
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 10 · 2023: 10
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
- Keywords
- microgrid protection, distributed energy resources, short-circuit faults, fault current contribution, fault location estimation, adaptive protection, intelligent electronic devices, multi-agent systems, fault current limiter, energy storage systems, islanded operation, grid-connected operation, low-voltage distribution networks, protection system design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review