CoChat

Fuzzy Controllers Instead of Classical PIDs in HVAC Equipment: Dusting Off a Well-Known Technology and Today’s Implementation for Better Energy Efficiency and User Comfort

Chojecki, Adrian, Ambroziak, Arkadiusz, Borkowski, Piotr · 2023 · Energies
Cited by 25

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Cutting-edge building energy management systems (BEMS) interact with heating, ventilation, air conditioning (HVAC) systems, which generally account for much of the energy consumption. Major attention is focused on the BEMS themselves, barring on-field equipment. In HVAC equipment, sub-optimal controller settings may lead to energy losses and user discomfort, for instance, due to oscillations of air temperature and fan speeds. The way to solve this problem could be to replace classical PID controllers with an alternative concept that does not require tuning and works optimally for a wide range of parameters. This paper compares a fuzzy logic controller (FLC) with a standard PID for a model-based simulation of an HVAC system in Simulink for different conditions using real building measurement data. The end result is the implementation of the developed methods in a newly designed universal control board for air handling units (AHU). The proposed FLC achieves better integral control quality indicators (IAE, ISE, ITAE, ITSE) by at least 27.4%, and smaller supply air temperature variation; the daily mean square error (MSE) was reduced by an average of 36%, which leads immediately to better occupant comfort and a presumed reduction in energy consumption. Compared to the untuned PID, energy consumption was 12.7% lower; this will ensure improved economy from the lowest level, and paves the way for interoperability with high-level energy management schemes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en16072967

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 43

  1. Mir, 2021, Energy Management in Smart Buildings and Homes: Current Approaches, a Hypothetical Solution, and Open Issues and Challenges, IEEE Access, 9, 94132, 10.1109/ACCESS.2021.3092304 · DOI
  2. Khalil, 2022, Machine Learning, Deep Learning and Statistical Analysis for forecasting building energy consumption—A systematic review, Eng. Appl. Artif. Intell., 115, 105287, 10.1016/j.engappai.2022.105287 · DOI · Paper page
  3. Anastasiadou, M., Santos, V., and Dias, M.S. (2022). Machine Learning Techniques Focusing on the Energy Performance of Buildings: A Dimensions and Methods Analysis. Buildings, 12. · DOI
  4. Kini, P.G. (2011). Energy Management Systems, IntechOpen. Chapter 6. · doi:10.5772/739
  5. Naqbi, A.A., Alyieliely, S.S., Talib, M.A., Nasir, Q., Bettayeb, M., and Ghenai, C. (November2021, January 31). Energy Reduction in Building Energy Management Systems Using the Internet of Things: Systematic Literature Review. Proceedings of the 2021 International Symposium on Networks, Computers and Communications (ISNCC), Dubai, United Arab Emirates. · DOI
  6. Wang, 2022, Analysis of precooling optimization for residential buildings, Appl. Energy, 323, 119574, 10.1016/j.apenergy.2022.119574 · doi:10.1016/j.apenergy.2022.119574
  7. Naderi, S., Heslop, S., Chen, D., MacGill, I., and Pignatta, G. (2021). Cost-Saving through Pre-Cooling: A Case Study of Sydney. Environ. Sci. Proc., 12. · DOI
  8. Godina, R., Rodrigues, E.M.G., Pouresmaeil, E., and Catalão, J.P.S. (2017, January 6–9). Home HVAC energy management and optimization with model predictive control. Proceedings of the 2017 IEEE International Conference on Environment and Electrical Engineering and 2017 IEEE Industrial and Commercial Power Systems Europe (EEEIC/ICPS Europe), Milan, Italy. · DOI
  9. Talebi, 2020, Online fuzzy control of HVAC systems considering demand response and users’ comfort, Energy Sources Part B Econ. Plan. Policy, 15, 403, 10.1080/15567249.2020.1825557 · DOI
  10. Torabi, 2022, Common human errors in design, installation, and operation of VAV AHU control systems—A review and a practitioner interview, Build. Environ., 221, 109333, 10.1016/j.buildenv.2022.109333 · doi:10.1016/j.buildenv.2022.109333
  11. Ambroziak, 2023, The PID controller optimisation module using Fuzzy Self-Tuning PSO for Air Handling Unit in continuous operation, Eng. Appl. Artif. Intell., 117, 105485, 10.1016/j.engappai.2022.105485 · doi:10.1016/j.engappai.2022.105485
  12. McDowall, R., and Montgomery, R. (2008). Fundamentals of HVAC Control Systems, Elsevier Science. · doi:10.1016/b978-0-08-055233-0.00001-7
  13. Jovic, F. (1992). Process Control Systems: Principles of Design, Operation and Interfacing, Springer.
  14. Cominos, 2002, PID controllers: Recent tuning methods and design to specification, IEE Proc.-Control Theory Appl., 149, 46, 10.1049/ip-cta:20020103 · DOI
  15. Naidu, D.S. (2003). Optimal Control Systems, CRC Press.
  16. Pandey, S.K., Veeranna, K., Kumar, B., and Deshmukh, K.U. (2020, January 18–21). A Robust Auto-tuning Scheme for PID Controllers. Proceedings of the IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society, Singapore. · doi:10.1109/iecon43393.2020.9254382
  17. Zhu, 2015, An adaptive artificial neural network-based supply air temperature controller for air handling unit, Trans. Inst. Meas. Control, 37, 1118, 10.1177/0142331214557171 · doi:10.1177/0142331214557171
  18. Hongli, L., Peiyong, D., and Lei, J. (2008, January 25–27). A Novel Fuzzy Controller Design based-on PID Gains for HVAC Systems. Proceedings of the 2008 7th World Congress on Intelligent Control and Automation, Chongqing, China.
  19. Jun, Z., and Kanyu, Z. (2011, January 6–7). A Particle Swarm Optimization Approach for Optimal Design of PID Controller for Temperature Control in HVAC. Proceedings of the 2011 Third International Conference on Measuring Technology and Mechatronics Automation, Shanghai, China. · doi:10.1109/icmtma.2011.63
  20. Zadeh, 1965, Fuzzy sets, Inf. Control, 8, 338, 10.1016/S0019-9958(65)90241-X · DOI · Paper page
  21. Leondes, C.T. (1998). Fuzzy Logic and Expert Systems Applications, Academic Press.
  22. Siler, W., and Buckley, J.J. (2005). Fuzzy Expert Systems and Fuzzy Reasoning, John Wiley & Sons. · DOI · Paper page
  23. Mamdani, 1975, An experiment in linguistic synthesis with a fuzzy logic controller, Int. J.-Man-Mach. Stud., 7, 1, 10.1016/S0020-7373(75)80002-2 · DOI · Paper page
  24. Chiu, 1998, Using fuzzy logic in control applications: Beyond fuzzy PID control, IEEE Control Syst. Mag., 18, 100, 10.1109/37.722256 · doi:10.1109/37.722256
  25. Nguyen, 2019, Fuzzy Control Systems: Past, Present and Future, IEEE Comput. Intell. Mag., 14, 56, 10.1109/MCI.2018.2881644 · DOI
  26. Wiktorowicz, 2005, O doborze regul sterowania dla regulatora rozmytego, Pomiary Autom. Kontrola, 51, 44
  27. Zajdel, 2005, Uczenie ze wzmocnieniem regulatora Takagi-Sugeno metoda elementow ASE/ACE, Pomiary Autom. Kontrola, 51, 47
  28. Castillo, 2014, A review on interval type-2 fuzzy logic applications in intelligent control, Inf. Sci., 279, 615, 10.1016/j.ins.2014.04.015 · DOI
  29. Galluzzo, 2010, Adaptive type-2 fuzzy logic control of a bioreactor, Chem. Eng. Sci., 65, 4208, 10.1016/j.ces.2010.04.023 · doi:10.1016/j.ces.2010.04.023
  30. Taghieh, 2022, A type-3 fuzzy control for current sharing and voltage balancing in microgrids, Appl. Soft Comput., 129, 109636, 10.1016/j.asoc.2022.109636 · DOI
  31. Almabrok, A., Psarakis, M., and Dounis, A. (2018). Fast Tuning of the PID Controller in An HVAC System Using the Big Bang–Big Crunch Algorithm and FPGA Technology. Algorithms, 11. · DOI
  32. Rugh, 2000, Research on gain scheduling, Automatica, 36, 1401, 10.1016/S0005-1098(00)00058-3 · DOI · Paper page
  33. Saxena, 2012, Advances in internal model control technique: A review and future prospects, IETE Tech. Rev., 29, 461, 10.4103/0256-4602.105001 · doi:10.4103/0256-4602.105001
  34. Datta, A. (2012). Adaptive Internal Model Control, Springer.
  35. Bhattacharya, 2003, An improved PID-type fuzzy controller employing individual fuzzy P, fuzzy I and fuzzy D controllers, Trans. Inst. Meas. Control, 25, 352, 10.1191/0142331203tm094oa · doi:10.1191/0142331203tm094oa
  36. Sun, Y., Zheng, Z., Hou, X., and Tian, P. (2009, January 7–9). AHU Control Strategies in the VAV System. Proceedings of the 2009 Fourth International Conference on Innovative Computing, Information and Control (ICICIC), Kaohsiung, Taiwan. · doi:10.1109/icicic.2009.72
  37. Rajkumar, 2013, Optimization of AHU control strategy, Int. J. Innov. Technol. Res., 1, 124
  38. Png, 2019, An internet of things upgrade for smart and scalable heating, ventilation and air-conditioning control in commercial buildings, Appl. Energy, 239, 408, 10.1016/j.apenergy.2019.01.229 · DOI · Paper page
  39. Hahn, A., Singh, R., Liu, C.C., and Chen, S. (2017, January 23–26). Smart contract-based campus demonstration of decentralized transactive energy auctions. Proceedings of the 2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), Washington, DC, USA. · DOI · Paper page
  40. Taraate, V. (2022). Digital Logic Design Using Verilog: Coding and RTL Synthesis, Springer. · doi:10.1007/978-981-16-3199-3
  41. Holman, J. (2010). Heat Transfer: Tenth Edition, McGraw-Hill Education.
  42. Zhang, 2011, Air temperature thresholds for indoor comfort and perceived air quality, Build. Res. Inf., 39, 134, 10.1080/09613218.2011.552703 · DOI · Paper page
  43. Marik, 2011, Advanced HVAC Control: Theory vs. Reality, IFAC Proc. Vol., 44, 3108, 10.3182/20110828-6-IT-1002.03085 · DOI

Cited by

See all 25

Metadata

Authors
Chojecki, A., Ambroziak, A., & Borkowski, P.
Affiliations
Department of Electrical Apparatus, Faculty of Electrical, Electronic, Computer and Control Engineering, Lodz University of Technology, 90-537 Lodz, Poland
Venue
Energies
Publisher
MDPI AG
Published
2023-03-24
Volume
16
Issue
7
Pages
2967
ISSN
1996-1073
Cited by
25
References
1
Language
en
Funders
Polish Agency for Enterprise Development (POIR.02.03.02-24-0041/18)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.