Predicting the Temperature Rise in Oil-Immersed Transformers Based on the Identification of Thermal Circuit Model Parameters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The temperature rise test for transformers is time-consuming, energy-intensive, and has low detection efficiency. To improve the efficiency of the temperature rise test and reduce energy consumption, this paper proposes a temperature rise prediction method for oil-immersed transformer windings. This method is based on identifying the parameters of a thermal circuit model. Firstly, a fifth-order thermal circuit model of oil-immersed transformers is put forward. Then, based on a two-hour temperature rise curve, the thermal capacity and resistance model is identified through genetic algorithms. The obtained parameters are used to compute the temperature rise curve, steady-state average temperature rise, and top oil temperature rise. The results show that the heat capacities of the low-voltage (LV) winding, high-voltage (HV) winding, oil tank, and oil of a 400 kVA transformer are approximately 50 kJ/K, 75 kJ/K, 320 kJ/K, and 90 kJ/K, respectively. Additionally, the thermal resistances from the LV winding to oil, HV winding to oil, oil tank, and air are about 8 mK/W, 5 mK/W, 1 mK/W, and 11 mK/W, respectively. When the transformer capacity increases, the heating power of the windings escalates, and the oil resistance of HV windings decreases from 8 mK/W for a 400 kVA capacity to 5 mK/W for an 800 kVA capacity. The absolute prediction error for transformers of 400 kVA, 630 kVA, and 800 kVA is 2.9 °C. These findings can facilitate the swift detection and assessment of the winding temperature rise in oil-immersed transformers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In accordance with the IEEE 57.110 standard and the transformer's specifications [32], the harmonic-related losses were assessed: PEC is equal to 299.9 W, and Pstr is also 299.9 W.”
From Harmonic Mitigation Solutions for Industrial Connections with Variable Frequency Drives: Meeting the Standards and Beyond (2026) · cites this paper as [32]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Thermal Modelling of Power Transformers
Susa, D., Lehtonen, M., & Nordman, H. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835255 · Cited by 351
Research works printed but not linked: 34
- Wen, Q., Baohui, Z., Zhiguo, H., and Zhiqian, B. (2014, January 20–22). Simulation and analysis of oil-immersed transformer based on thermal-fluid coupled field. Proceedings of the 2014 International Conference on Power System Technology, Chengdu, China.
- Hao, Y., Zhang, Z., Xiao, J., Zhao, H., Yang, Y., and Dong, Z. (2024). Study on Thermal Characteristics of Winding Under Inter-Turn Fault of Oil-Immersed Transformer. Electronics, 13. · doi:10.3390/electronics13142869
- 1993, On the determination of characteristic temperatures in power oil transformers during transient states, Arch. Für Elektrotechnik, 76, 457, 10.1007/BF01576026 · doi:10.1007/bf01576026
- Liao, 2014, 3-D Coupled Electromagnetic-Fluid-Thermal Analysis of Oil-Immersed Triangular Wound Core Transformer, IEEE Trans. Magn., 50, 1, 10.1109/TMAG.2014.2330953 · doi:10.1109/tmag.2014.2330953
- Wang, 2016, 3D Coupled Electromagnetic-Thermal-Fluid Method for Computation of Temperature Field of Converter Transformer RIP Bushings, Proc. CSEE, 36, 6269
- Torriano, 2010, Numerical study of parameters affecting the temperature distribution in a disc-type transformer winding, Appl. Therm. Eng., 30, 2034, 10.1016/j.applthermaleng.2010.05.004 · doi:10.1016/j.applthermaleng.2010.05.004
- Swift, 2002, A fundamental approach to transformer thermal modeling, I. Theory and equivalent circuit, IEEE Trans. Power Deliv., 16, 171, 10.1109/61.915478 · DOI · Paper page
- Gerling, D., and Dajaku, G. (2005, January 11–14). Novel lumped-parameter thermal model for electrical systems. Proceedings of the 2005 European Conference on Power Electronics and Applications, Dresden, Germany. · doi:10.1109/epe.2005.219225
- Li, 2023, Test and Analysis on Extended Temperature Rise of 110 kV Transformer Based on Distributed Temperature Sensing, IEEE Trans. Power Deliv., 38, 1030, 10.1109/TPWRD.2022.3204333 · DOI
- Tembo, F., Bragone, F., Laneryd, T., Barreau, M., and Morozovska, K. (2025). Data-Driven vs Traditional Approaches to Power Transformers’ Top-Oil Temperature Estimation. arXiv. · doi:10.2139/ssrn.5293047
- Wang, 2017, Numerical and experimental validation of variation of power transformers’ thermal time constants with load factor, Appl. Therm. Eng., 126, 939, 10.1016/j.applthermaleng.2017.07.167 · DOI
- Silin, 2018, An experimental study of natural convection in a distribution transformer slice model, Int. J. Therm. Sci., 129, 94, 10.1016/j.ijthermalsci.2018.02.029 · doi:10.1016/j.ijthermalsci.2018.02.029
- Martinez, 2010, Bragg system for temperature monitoring in distribution transformers—ScienceDirect, Electr. Power Syst. Res., 80, 77, 10.1016/j.epsr.2009.08.013 · doi:10.1016/j.epsr.2009.08.013
- Liu, Y., Li, X., Li, H., Wang, J., and Fan, X. (2020). Experimental and Numerical Investigation of the Internal Temperature of an Oil-Immersed Power Transformer with DOFS. Appl. Sci., 10. · doi:10.3390/app10165718
- Huang, 2007, Evolving wavelet networks for power transformer condition monitoring, IEEE Power Eng. Rev., 22, 63
- Feng, J., Feng, Z., Jiang, G., Zhang, G., Jin, W., and Zhu, H. (2024). A Prediction Method for the Average Winding Temperature of a Transformer Based on the Fully Connected Neural Network. Appl. Sci., 14. · doi:10.3390/app14156841
- Song, H., Yao, H., Wei, X., Qin, H., Li, Y., Lv, K., and Chen, Q. (2023). Experimental Study on Fire Suppression of the Outdoor Oil-Immersed Transformer by High-Pressure Water Mist System. Fire, 6. · doi:10.3390/fire6060238
- You, Y., Shao, K., and Yi, Z. (2023). Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation. Entropy, 25. · DOI
- Liu, 2022, Research of the Loss of Power Transformer Structure, IEEJ Trans. Electr. Electron. Eng., 2320, 012017
- Wang, 2025, Structure Design of a Four-Pillar Magnetically Integrated Fractional-Turn Planar Transformer and its Loss Analysis, IEEJ Trans. Electr. Electron. Eng., 20, 208, 10.1002/tee.24186 · doi:10.1002/tee.24186
- Dou, 2024, Analysis of Parasitic Parameters and Winding Loss Characteristics of High-Frequency Transformer under Different Winding Structures, J. Phys. Conf. Ser., 2774, 012029, 10.1088/1742-6596/2774/1/012029 · doi:10.1088/1742-6596/2774/1/012029
- Wei, 2012, Algorithm for Transformer Top-Oil Temperature and Winding Hot-Point Temperature Based on Modified Thermal Circuit Model, East China Electr. Power, 40, 444
- Xu, W. (2024). Review of Studies on the Hot Spot Temperature of Oil-Immersed Transformers. Energies, 18. · DOI
- Smolyanov, I., Shmakov, E., Butusov, D., and Khalyasmaa, A.I. (2024). Review of Modeling Approaches for Conjugate Heat Transfer Processes in Oil-Immersed Transformers. Computation, 12. · DOI
- Taghikhani, 2024, Heat transfer modeling in a transformer using magneto-CFD analysis and GWO algorithm considering dynamic thermal model, Results Eng., 23, 102856, 10.1016/j.rineng.2024.102856 · doi:10.1016/j.rineng.2024.102856
- Liang, J., Liang, K., Shao, Z., Niu, Y., Song, X., Sun, P., and Feng, J. (2024). Research on Temperature-Rise Characteristics of Motor Based on Simplified Lumped-Parameter Thermal Network Model. Energies, 17. · doi:10.3390/en17184717
- Tang, W.H., and Wu, Q.H. (2011). Thermoelectric Analogy Thermal Models of Power Transformers. Condition Monitoring and Assessment of Power Transformers Using Computational Intelligence. Power Systems, Springer. · doi:10.1007/978-0-85729-052-6
- Ding, 2019, Distributed Thermal Circuit Model of Oil-immersed Distribution Transformers, High Volt. Eng., 45, 968
- Wang, 2015, Improved Thermal Circuit Model of Hot Spot Temperature in Oil-immersed Transformers Based on Heat Distribution of Winding, High Volt. Eng., 41, 895
- Weigen, 2009, Power transformer top-oil temperature model based on thermal-electric analogy theory, Eur. Trans. Electr. Power Eng., 19, 341, 10.1002/etep.217 · DOI
- Faiz, 2019, Thermal Analysis of Power Transformer Using an Improved Dynamic Thermal Equivalent Circuit Model, Electr. Power Compon. Syst., 47, 1598, 10.1080/15325008.2019.1689452 · DOI
- Moradi, 2012, Combination of Genetic Algorithm and Particle Swarm Optimization for Optimal Distributed Generation Location and Sizing in Distribution Systems with Fuzzy Optimal Theory, Int. J. Green Energy, 9, 641, 10.1080/15435075.2011.625590 · doi:10.1080/15435075.2011.625590
- Soltani, 2011, Heat exchanger networks retrofit with considering pressure drop by coupling genetic algorithm with LP (linear programming) and ILP (integer linear programming) methods, Energy, 36, 2381, 10.1016/j.energy.2011.01.017 · doi:10.1016/j.energy.2011.01.017
- (2012). IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators (Standard No. C57.91-2011).
Cited by
Diahovchenko, I., Najafi, E., & O'Donnell, T. (2026) · IEEE Access · doi:10.1109/access.2026.3682461
“An industrial-scale air-to-water heat pump of 400 kW capacity is installed at a university campus and connected to the MV grid via a delta-star transformer with a rated power of 630 kVA, with the parameters as per [32].”
Influential
Metadata
- Authors
- Hu, Y., Wang, L., Li, J., Weng, H., Zheng, Z., Wen, G., & Zhang, F.
- Affiliations
- Zhejiang Huadian Equipment Testing and Research Institute Co., Ltd., Hangzhou 310022, China
- State Grid Zhejiang Electric Power Co., Ltd. Materials Branch, Hangzhou 310022, China
- State Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2025-09-04
- Volume
- 18
- Issue
- 17
- Pages
- 4707
- ISSN
- 1996-1073
- Cited by
- 4
- References
- 1
- Language
- en
- Funders
- Science and Technology Project of the State Grid Corporation of China (5700-202319605A-3-2-ZN)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.