CoChat

Experimental Characterization of the Poisoning Effects of Methanol-Based Reformate Impurities on a PBI-Based High Temperature PEM Fuel Cell

Open access
Araya, Samuel, Andreasen, Søren, Kær, Søren · 2012 · Energies
Cited by 51

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In this work the effects of reformate gas impurities on a H3PO4-doped polybenzimidazole (PBI) membrane-based high temperature proton exchange membrane fuel cell (HT-PEMFC) are studied. A unit cell assembly with a BASF Celtec®-P2100 high temperature membrane electrode assembly (MEA) of 45 cm2 active surface area is investigated by means of impedance spectroscopy. The concentrations in the anode feed gas of all impurities, unconverted methanol-water vapor mixture, CO and CO2 were varied along with current density according to a multilevel factorial design of experiments. Results show that all the impurities degrade the performance, with CO being the most degrading agent and CO2 the least. The factorial analysis shows that there is interdependence among the effects of the different factors considered. This interdependence suggests, for example, that tolerances to concentrations of CO above 2% may be compromised by the presence in the anode feed of CO2. Methanol has a poisoning effect on the fuel cell at all the tested feed ratios, and the performance drop is found to be proportional to the amount of methanol in feed gas. The effects are more pronounced when other impurities are also present in the feed gas, especially at higher methanol concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en5114251

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 38

  1. Ji, 2008, Methanol distribution and electroosmotic drag in hydrated poly(perfluorosulfonic) acid membrane, J. Phys. Chem. B, 112, 15616, 10.1021/jp8066469 · DOI
  2. Ogden, 1999, A comparison of hydrogen, methanol and gasoline as fuels for fuel cell vehicles: implications for vehicle design and infrastructure development, J. Power Sources, 79, 143, 10.1016/S0378-7753(99)00057-9 · DOI · Paper page
  3. Olah, G.A., Goeppert, A., and Prakash, G.K. S. (2009). Beyond Oil and Gas: The Methanol Economy, Wiley-VCH. [2nd ed.]. · DOI · Paper page
  4. Pan, 2005, Integration of high temperature PEM fuel cells with a methanol reformer, J. Power Sources, 145, 392, 10.1016/j.jpowsour.2005.02.056 · DOI · Paper page
  5. Ouzounidou, 2009, A Combined methanol autothermal steam reforming and PEM fuel cell pilot plant unit: Experimental and simulation studies, Energy, 34, 1733, 10.1016/j.energy.2009.06.031 · DOI
  6. Bhatia, K.K. (2004). Study of Methanol Reforming Polymer Electrolyte Fuel Cell System. [Ph.D. Thesis, College of Engineering, The Graduate School, The Pennsylvania State University].
  7. Andreasen, 2011, High temperature PEM fuel cell performance characterisation with CO and CO2 using electrochemical impedance spectroscopy, Int. J. Hydrog. Energy, 3, 9815, 10.1016/j.ijhydene.2011.04.076 · doi:10.1016/j.ijhydene.2011.04.076
  8. Buchi, F.N., Inaba, M., and Schmidt, T.J. (2009). Polymer Electrolyte Fuel Cell Durability, Springer. · DOI · Paper page
  9. Zhang, 2006, High Temperature PEM Fuel Cells, J. Power Sources, 160, 872, 10.1016/j.jpowsour.2006.05.034 · DOI · Paper page
  10. Das, 2009, Experimental evaluation of CO poisoning on the performance of a high temperature proton exchange membrane fuel cell, J. Power Sources, 193, 691, 10.1016/j.jpowsour.2009.04.021 · DOI · Paper page
  11. Yan, 2009, Degradation of Proton Exchange Membrane Fuel Cells Due to CO and CO2 Poisoning, J. Power Sources, 188, 141, 10.1016/j.jpowsour.2008.11.107 · DOI
  12. Bellows, 1996, Analysis of reaction kinetics for carbon monoxide and carbon dioxide on polycrystalline platinum relative to fuel cell operation, Ind. Eng. Chem. Res., 3, 1235, 10.1021/ie950580m · DOI
  13. Cheng, 2007, A review of PEM hydrogen fuel cell contamination: Impacts, mechanisms, and mitigation, J. Power Sources, 165, 739, 10.1016/j.jpowsour.2006.12.012 · DOI · Paper page
  14. Du, 2007, Effect of methanol crossover on the cathode behavior of a DMFC: A half-cell investigation, Electrochim. Acta, 52, 5266, 10.1016/j.electacta.2007.01.089 · DOI
  15. Araya, 2012, Vapor delivery systems for the study of the effects of reformate gas impurities in HT-PEM fuel cells, J. Fuel Cell Sci. Technol., 9, 015001, 10.1115/1.4005123 · DOI
  16. Yuan, X.Z., Song, C., Wang, H., and Zhang, J. (2010). Electrochemical Impedance Spectroscopy in PEM Fuel Cells: Fundamentals and Applications, Springer. · DOI · Paper page
  17. Mamlouk, 2011, Analysis of high temperature polymer electrolyte membrane fuel cell electrodes using electrochemical impedance spectroscopy, Electrochim. Acta, 56, 5493, 10.1016/j.electacta.2011.03.056 · DOI
  18. Zhang, 2009, EIS assisted performance analysis of non-noble metal electro-catalyst (FeN/C)-based PEM fuel cells in the temperature range of 23–80 °C, Electrochim. Acta, 54, 1737, 10.1016/j.electacta.2008.10.006 · doi:10.1016/j.electacta.2008.10.006
  19. Asghari, 2010, Study of PEM fuel cell performance by electrochemical impedance spectroscopy, Int. J. Hydrog. Energy, 35, 9283, 10.1016/j.ijhydene.2010.03.069 · DOI
  20. Fouquet, 2006, Model based PEM fuel cell state-of-health monitoring via AC impedance measurements, J. Power Sources, 159, 905, 10.1016/j.jpowsour.2005.11.035 · DOI
  21. Pattamarat, 2008, Testing of PEM fuel cell performance by electrochemical impedance spectroscopy: Optimum condition for low relative humidification cathode, Korean J. Chem. Eng., 25, 245, 10.1007/s11814-008-0044-z · doi:10.1007/s11814-008-0044-z
  22. Barsoukov, E., and Macdonald, J.R. (2005). Impedance Spectroscopy: Theory, Experiment, and Applications, Wiley-Interscience. [2nd ed.]. · DOI · Paper page
  23. Orazem, M.E., and Tribollet, B. (2008). Electrochemical Impedance Spectroscopy, John Wiley & Sons. · DOI · Paper page
  24. Monk, P. (2007). Fundamentals of Electroanalytical Chemistry, Analytical Techniques in the Sciences, John Wiley & Sons.
  25. Yuan, 2007, AC impedance technique in PEM fuel cell diagnosis–A review, Int. J. Hydrog. Energy, 32, 4365, 10.1016/j.ijhydene.2007.05.036 · DOI · Paper page
  26. Andreasen, S.J., Mosbæk, R., Vang, J.R., Kær, S.K., and Araya, S.S. (2010, January 14–16). EIS characterization of the poisoning effects of CO and CO2 on a PBI based HT-PEM fuel cell. Proceeding of the 8th International Conference on Fuel Cell Science, Engineering and Technology, New York, NY, USA. · doi:10.1115/fuelcell2010-33054
  27. Pan, 2005, Modeling of a compact plate-fin reformer for methanol steam reforming in fuel cell systems, Chem. Eng. J., 108, 51, 10.1016/j.cej.2004.12.042 · DOI
  28. Agrell, 2002, Steam reforming of methanol over a Cu/ZnO/Al2O3 catalyst: A kinetic analysis and strategies for suppression of CO formation, J. Power Sources, 106, 249, 10.1016/S0378-7753(01)01027-8 · DOI · Paper page
  29. Tsai, 1982, Nonlinear least-squares analyses of complex impedance and admittance data for solid electrolytes, Solid State Ion., 7, 129, 10.1016/0167-2738(82)90006-6 · doi:10.1016/0167-2738(82)90006-6
  30. Bhatia, 2004, Transient carbon monoxide poisoning of a polymer electrolyte fuel cell operating on diluted hydrogen feed, Electrochim. Acta, 49, 2333, 10.1016/j.electacta.2004.01.014 · DOI
  31. Papageorgopoulos, 2002, The Influence of Carbon Dioxide on PEM Fuel Cell Anodes, J. Power Sources, 110, 117, 10.1016/S0378-7753(02)00227-6 · DOI · Paper page
  32. Daletou, 2009, The interaction of water vapors with H3PO4 imbibed electrolyte based on PBI/polysulfone copolymer blends, J. Memb. Sci., 326, 76, 10.1016/j.memsci.2008.09.040 · DOI
  33. Li, 2009, High temperature proton exchange membranes based on polybenzimidazoles for fuel cells, Prog. Polym. Sci., 34, 449, 10.1016/j.progpolymsci.2008.12.003 · DOI · Paper page
  34. Sriramulu, 1999, Reaction Mechanism and Dynamics of Methanol Electrooxidation on Platinum (111), J. Electroanal. Chem., 467, 132, 10.1016/S0022-0728(99)00036-4 · doi:10.1016/s0022-0728(99)00036-4
  35. Spendelow, 2005, Electrocatalytic oxidation of carbon monoxide and methanol on platinum surfaces decorated with ruthenium, Curr. Opin. Solid State Mater. Sci., 9, 37, 10.1016/j.cossms.2006.02.009 · DOI
  36. Cao, 2005, Mechanisms of methanol decomposition on platinum: A combined experimental and ab initio approach, J. Phys. Chem. B, 109, 11622, 10.1021/jp0501188 · DOI
  37. Iwasita, 2002, Electrocatalysis of methanol oxidation, Electrochim Acta, 47, 3663, 10.1016/S0013-4686(02)00336-5 · DOI · Paper page
  38. Makharia, 2005, Measurement of catalyst layer electrolyte resistance in PEFCs using electrochemical impedance spectroscopy, J. Electrochem. Soc., 152, 970, 10.1149/1.1888367 · DOI · Paper page

Cited by

See all 51

Metadata

Authors
Araya, S., Andreasen, S., & Kær, S.
Venue
Energies
Publisher
MDPI AG
Published
2012-10-24
Volume
5
Issue
11
Pages
4251-4267
ISSN
1996-1073 (ISSN-L)
OpenAlex
W2151899994
Cited by
51
References
1
FWCI
1.63
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Characterization of the Poisoning Effects of Methanol-Based Reformate Impurities on a PBI-Based High Temperature PEM Fuel Cell. https://app.cochat.ai/papers/10.3390/en5114251
The paper
Araya, S., Andreasen, S., & Kær, S. (2012). Experimental Characterization of the Poisoning Effects of Methanol-Based Reformate Impurities on a PBI-Based High Temperature PEM Fuel Cell. Energies. https://doi.org/10.3390/en5114251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.