The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Methodologies and Advancements in the Calibration of Building Energy Models
Open accessAbstract
Buildings do not usually perform during operation as well as predicted during the design stage. Disagreement between simulated and metered energy consumption represents a common issue in building simulation. For this reason, the calibration of building simulation models is of growing interest. Sensitivity and uncertainty analyses play an important role in building model accuracy. They can be used to identify the building model parameters most influent on the energy consumption. Given this, these analyses should be integrated within calibration methodologies and applications for tuning the parameters. This paper aims at providing a picture of the state of the art of calibration methodologies in the domain of building energy performance assessment. First, the most common methodologies for calibration are presented, emphasizing criticalities and gaps that can be faced. In particular the main issues to be addressed, when carrying out calibrated simulation, are discussed. The standard statistical criteria for considering the building models calibrated and for evaluating their goodness-of-fit are also presented. Second, the commonly used techniques for investigating uncertainties in building models are reviewed. Third, a review of the latest main studies in the calibrated simulation domain is presented. Criticalities and recommendations for new studies are finally provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Sensitivity Analysis. The Primer
Saltelli, A., Ratto, M., Andres, T., Campolongo, F., Cariboni, J., Gatelli, D., Saisana, M., & Tarantola, S. (2007) · doi:10.1002/9780470725184 · Cited by 6,430
Factorial Sampling Plans for Preliminary Computational Experiments
Morris, M. D. (1991) · Technometrics · doi:10.1080/00401706.1991.10484804 · Cited by 4,943
A Quantitative Model-Independent Method for Global Sensitivity Analysis of Model Output
Saltelli, A., Tarantola, S., & Chan, K. P.-S. (1999) · Technometrics · doi:10.1080/00401706.1999.10485594 · Cited by 2,275
A review on simulation-based optimization methods applied to building performance analysis
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.061 · Cited by 1,379
Cited by
A review on simulation-based optimization methods applied to building performance analysis
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.061 · Cited by 1,379
Ferrando, M., Causone, F., Hong, T., & Chen, Y. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102408 · Cited by 379
Sokol, J., Cerezo Davila, C., & Reinhart, C. F. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2016.10.050 · Cited by 270
Perspectives on the integration between first-principles and data-driven modeling
Bradley, W., Kim, J., Kilwein, Z., Blakely, L., Eydenberg, M., Jalvin, J., Laird, C., & Boukouvala, F. (2022) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2022.107898 · Cited by 231
Nutkiewicz, A., Yang, Z., & Jain, R. K. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.023 · Cited by 223
Metadata
- Authors
- Fabrizio, E., & Monetti, V.
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2015-03-31
- Volume
- 8
- Issue
- 4
- Pages
- 2548-2574
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W2002954424
- Cited by
- 233
- References
- 4
- FWCI
- 24.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methodologies and Advancements in the Calibration of Building Energy Models. https://app.cochat.ai/papers/10.3390/en8042548
- The paper
- Fabrizio, E., & Monetti, V. (2015). Methodologies and Advancements in the Calibration of Building Energy Models. Energies. https://doi.org/10.3390/en8042548
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.