CoChat

Are Metals Emitted from Electronic Cigarettes a Reason for Health Concern? A Risk-Assessment Analysis of Currently Available Literature

Open access
Farsalinos, Konstantinos, Voudris, Vassilis, Poulas, Konstantinos · 2015 · International Journal of Environmental Research and Public Health
Cited by 101

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Studies have found that metals are emitted to the electronic cigarette (EC) aerosol. However, the potential health impact of exposure to such metals has not been adequately defined. The purpose of this study was to perform a risk assessment analysis, evaluating the exposure of electronic cigarette (EC) users to metal emissions based on findings from the published literature. Methods: Two studies were found in the literature, measuring metals emitted to the aerosol from 13 EC products. We estimated that users take on average 600 EC puffs per day, but we evaluated the daily exposure from 1200 puffs. Estimates of exposure were compared with the chronic Permissible Daily Exposure (PDE) from inhalational medications defined by the U.S. Pharmacopeia (cadmium, chromium, copper, lead and nickel), the Minimal Risk Level (MRL) defined by the Agency for Toxic Substances and Disease Registry (manganese) and the Recommended Exposure Limit (REL) defined by the National Institute of Occupational Safety and Health (aluminum, barium, iron, tin, titanium, zinc and zirconium). Results: The average daily exposure from 13 EC products was 2.6 to 387 times lower than the safety cut-off point of PDEs, 325 times lower than the safety limit of MRL and 665 to 77,514 times lower than the safety cut-off point of RELs. Only one of the 13 products was found to result in exposure 10% higher than PDE for one metal (cadmium) at the extreme daily use of 1200 puffs. Significant differences in emissions between products were observed. Conclusions: Based on currently available data, overall exposure to metals from EC use is not expected to be of significant health concern for smokers switching to EC use, but is an unnecessary source of exposure for never-smokers. Metal analysis should be expanded to more products and exposure can be further reduced through improvements in product quality and appropriate choice of materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijerph120505215

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 101

Metadata

Authors
Farsalinos, K., Voudris, V., & Poulas, K.
Venue
International Journal of Environmental Research and Public Health
Publisher
MDPI AG
Published
2015-05-15
Volume
12
Issue
5
Pages
5215-5232
ISSN
1660-4601 (ISSN-L)
OpenAlex
W2121201834
Cited by
101
References
2
FWCI
7.32
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.