Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO2, CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants’ perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m3 recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m3 in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m3) and afternoon (1358 cfu/m3). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO2 concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants’ preferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The SAS air sampler was previously used for monitoring airborne microorganisms in various indoor and outdoor occupational and recreational environments [34,35].”
From Exposure Levels of Airborne Fungi, Bacteria, and Antibiotic Resistance Genes in Cotton Farms during Cotton Harvesting and Evaluations of N95 Respirators against These Bioaerosols (2023) · cites this paper as [34]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Literature survey on how different factors influence human comfort in indoor environments
Frontczak, M., & Wargocki, P. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.10.021 · Cited by 1,248
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Thermal comfort and gender: a literature review
Karjalainen, S. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00747.x · Cited by 536
Gender differences in thermal comfort and use of thermostats in everyday thermal environments
Karjalainen, S. (2007) · Building and Environment · doi:10.1016/j.buildenv.2006.01.009 · Cited by 452
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
The medical effects of mold exposure
Bush, R. K., Portnoy, J. M., Saxon, A., Terr, A. I., & Wood, R. A. (2006) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.12.001 · Cited by 337
Gender differences in office occupant perception of indoor environmental quality (IEQ)
Kim, J., de Dear, R., Cândido, C., Zhang, H., & Arens, E. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.022 · Cited by 267
Thermal comfort in offices in India: Behavioral adaptation and the effect of age and gender
Indraganti, M., Ooka, R., & Rijal, H. B. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.042 · Cited by 207 · cited 1×
“These studies reported similar findings where the female respondents reported less satisfaction around each variable considered [15,16].”
Result
Research works printed but not linked: 3
- Humphreys, M.A., and Nicol, J.F. (2020, February 26). Self-Assessed Productivity and the Office Environment: Monthly Surveys in Five European Countries. ASHRAE Transactions. Available online: http://www.thefreelibrary.com/_/print/PrintArticle.aspx?id=164927243.
- Musa, H.M., Aidoo, K.A., and Hunter, C.A. (2009, January 13–17). The Occurrence of Aflatoxins, Mutagenicity and Cytotoxicity Nature of Dust Samples from a Converted Library Block into Office Space. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.
- Musa, H.M., Hunter, C.A., and Aidoo, K.A. (2009, January 13–17). Cytotoxicity and MVOCs Released by Stachybotrys Chartarum Isolated from Water Damaged Residential Buildings in Glasgow. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.
Cited by
Awada, M., Becerik-Gerber, B., White, E., Hoque, S., O’Neill, Z. D., Pedrielli, G., Wen, J., & Wu, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108440 · Cited by 118
Niza, I. L., de Souza, M. P., da Luz, I. M., & Broday, E. E. (2023) · Indoor and Built Environment · doi:10.1177/1420326x231191079 · Cited by 93
Post-Occupancy Evaluation’s (POE) Applications for Improving Indoor Environment Quality (IEQ)
Lolli, F., Marinello, S., Coruzzolo, A. M., & Butturi, M. A. (2022) · Toxics · doi:10.3390/toxics10100626 · Cited by 57
Dam-Krogh, E. P., Rupp, R. F., Clausen, G., & Toftum, J. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.108911 · Cited by 46
Aziz, N., Adman, M. A., Suhaimi, N. S., Misbari, S., Alias, A. R., Aziz, A. A., Lee, L. F., & Khan, M. M. H. (2023) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1140/1/012007 · Cited by 30
Metadata
- Authors
- Fahad Alomirah, H., & Moda, H. M.
- Affiliations
- College of Health Sciences, Shawaik, P.O. Box 1983, Safat 13020, Kuwait
- Manchester Metropolitan University (GB)
- Corresponding author
- Moda, Haruna Musa
- ORCID
- Moda, Haruna Musa
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2020-03-17
- Volume
- 17
- Issue
- 6
- Pages
- 1972
- ISSN
- 1660-4601 (ISSN-L)
- PMC
- PMC7143121
- OpenAlex
- W3011926615
- Cited by
- 34
- References
- 28
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 8 · 2022: 5 · 2021: 4 · 2020: 1
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- International Journal of Environmental Research and Public Health (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- e-space (Manchester Metropolitan University) (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- indoor air quality, building renovation, sick building syndrome, airborne microorganisms, airborne mold, total volatile organic compounds, carbon dioxide, carbon monoxide, thermal discomfort, office buildings
- MeSH terms
- England, Female, Fungi, Humans, Male, Perception, Temperature, Air Pollution, Indoor, Sick Building Syndrome, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester. https://app.cochat.ai/papers/10.3390/ijerph17061972
- The paper
- Fahad Alomirah, H., & Moda, H. M. (2020). Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph17061972
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.