Abstract

Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO2, CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants’ perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m3 recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m3 in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m3) and afternoon (1358 cfu/m3). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO2 concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants’ preferences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijerph17061972

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 3

  1. Humphreys, M.A., and Nicol, J.F. (2020, February 26). Self-Assessed Productivity and the Office Environment: Monthly Surveys in Five European Countries. ASHRAE Transactions. Available online: http://www.thefreelibrary.com/_/print/PrintArticle.aspx?id=164927243.
  2. Musa, H.M., Aidoo, K.A., and Hunter, C.A. (2009, January 13–17). The Occurrence of Aflatoxins, Mutagenicity and Cytotoxicity Nature of Dust Samples from a Converted Library Block into Office Space. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.
  3. Musa, H.M., Hunter, C.A., and Aidoo, K.A. (2009, January 13–17). Cytotoxicity and MVOCs Released by Stachybotrys Chartarum Isolated from Water Damaged Residential Buildings in Glasgow. Proceedings of the Paper Presented at the 9th International Conference and Exhibition of Healthy Buildings, Syracuse, NY, USA.

Cited by

See all 35

Metadata

Authors
Fahad Alomirah, H., & Moda, H. M.
Affiliations
  • College of Health Sciences, Shawaik, P.O. Box 1983, Safat 13020, Kuwait
  • Manchester Metropolitan University (GB)
Corresponding author
Moda, Haruna Musa
Venue
International Journal of Environmental Research and Public Health
Publisher
MDPI AG
Published
2020-03-17
Volume
17
Issue
6
Pages
1972
ISSN
1660-4601 (ISSN-L)
OpenAlex
W3011926615
Cited by
34
References
28
Citations by year
2026: 5 · 2025: 5 · 2024: 5 · 2023: 8 · 2022: 5 · 2021: 4 · 2020: 1
FWCI
1.80
Type
journal article
Language
en
Open access
Locations
  • International Journal of Environmental Research and Public Health (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • e-space (Manchester Metropolitan University) (acceptedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
indoor air quality, building renovation, sick building syndrome, airborne microorganisms, airborne mold, total volatile organic compounds, carbon dioxide, carbon monoxide, thermal discomfort, office buildings
MeSH terms
England, Female, Fungi, Humans, Male, Perception, Temperature, Air Pollution, Indoor, Sick Building Syndrome, Volatile Organic Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester. https://app.cochat.ai/papers/10.3390/ijerph17061972
The paper
Fahad Alomirah, H., & Moda, H. M. (2020). Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph17061972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.