Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 20

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study

Martinez-Cesteros, Javier, Medrano-Sanchez, Carlos, Plaza-Garcia, Inmaculada, Igual-Catalan, Raul, Albiol-Pérez, Sergio · 2021 · International Journal of Environmental Research and Public Health

Abstract

Center-of-pressure (CoP) displacements play a key role in studies assessing postural stability. The accepted instrument to measure CoP trajectories is the force platform, but pressure-sensitive mats (PSMs) are an alternative composed of a matrix of sensitive cells. A typical cell comprises two electrodes with piezoresistive material in between, while a force platform has a force sensor at each of its corners. In this paper, we compare a homemade Velostat-based PSM and an affordable commercial mat with a commercial force platform in a test series with 42 healthy volunteers in single-legged trials (29 males, 13 females; height 1.74 (0.09) m, weight 74.3 (16.34) kg, age 31.21 (12.66) years). The aim of the research was to perform a preliminary study of the performance of our prototype to measure CoP, and more specifically, the standard deviation of the CoP path on both axes, the medial–lateral and anterior–posterior. We could thus discover several improvements for future clinical applications. The intraclass correlation coefficient (ICC) for agreement in the base experiment showed a moderate value for the prototype (0.38 to 0.63) and lower values for the commercial mat (0.11 to 0.12). However, we identified several factors that were relevant to improve ICC and reduce error by considering several processing options: (i) the known crosstalk problem between cells that appears in this kind of mats must be eliminated; (ii) the response time of the sensor has to be taken into account; and (iii) increasing the mat resolution also improves agreement. Therefore, as future work, we plan to test the improved version of the prototype in a clinical environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijerph18115958

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 28

  1. Safi, K., Mohammed, S., Amirat, Y., and Khalil, M. (2017, January 19–21). Postural stability analysis—A review of techniques and methods for human stability assessment. Proceedings of the Fourth International Conference on Advances in Biomedical Engineering (ICABME), Beirut, Lebanon. · DOI
  2. Pajala, 2008, Force Platform Balance Measures as Predictors of Indoor and Outdoor Falls in Community-Dwelling Women Aged 63–76 Years, J. Gerontol. Ser. A, 63, 171, 10.1093/gerona/63.2.171 · DOI · Paper page
  3. Desai, 2010, Relationship Between Dynamic Balance Measures and Functional Performance in Community-Dwelling Elderly People, Phys. Ther., 90, 748, 10.2522/ptj.20090100 · doi:10.2522/ptj.20090100
  4. Li, 2016, Reliability and validity of center of pressure measures for balance assessment in older adults, J. Phys. Ther. Sci., 28, 1364, 10.1589/jpts.28.1364 · doi:10.1589/jpts.28.1364
  5. Dusing, 2009, Infants Born Preterm Exhibit Different Patterns of Center-of-Pressure Movement Than Infants Born at Full Term, Phys. Ther., 89, 1354, 10.2522/ptj.20080361 · DOI
  6. Maranesi, 2014, Functional reach test: Movement strategies in diabetic subjects, Gait Posture, 39, 501, 10.1016/j.gaitpost.2013.08.035 · doi:10.1016/j.gaitpost.2013.08.035
  7. Bickley, 2019, Comparison of simultaneous static standing balance data on a pressure mat and force plate in typical children and in children with cerebral palsy, Gait Posture, 67, 91, 10.1016/j.gaitpost.2018.08.012 · DOI
  8. Sheehy, 2020, Centre of pressure displacements produced in sitting during virtual reality training in younger and older adults and patients who have had a stroke, Disabil. Rehabil. Assist. Technol., 15, 924, 10.1080/17483107.2019.1629118 · DOI
  9. Ard, 2019, Validation Of The Tekscan Strideway Plantar Pressure Mat Compared To A Force Platform: 1348 Board #110 May 30 10:30 AM–12:00 PM, Med. Sci. Sport. Exerc., 51, 357, 10.1249/01.mss.0000561580.36179.b1 · doi:10.1249/01.mss.0000561580.36179.b1
  10. Goetschius, 2018, Validating Center-of-Pressure Balance Measurements Using the MatScan® Pressure Mat, J. Sport Rehabil., 27, 1, 10.1123/jsr.2017-0152 · DOI
  11. Nomura, 2009, A quantitative characterization of postural sway during human quiet standing using a thin pressure distribution measurement system, Gait Posture, 29, 654, 10.1016/j.gaitpost.2009.02.001 · doi:10.1016/j.gaitpost.2009.02.001
  12. Nag, 2017, Wearable Flexible Sensors: A Review, IEEE Sens. J., 17, 3949, 10.1109/JSEN.2017.2705700 · DOI · Paper page
  13. Li, W., Sun, C., Yuan, W., Gu, W., Cui, Z., and Chen, W. (2017, January 11–15). Smart mat system with pressure sensor array for unobtrusive sleep monitoring. Proceedings of the 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Jeju, Korea. · DOI
  14. Saenz-Cogollo, J.F., Pau, M., Fraboni, B., and Bonfiglio, A. (2016). Pressure Mapping Mat for Tele-Home Care Applications. Sensors, 16. · doi:10.3390/s16030365
  15. Xu, 2013, eCushion: A Textile Pressure Sensor Array Design and Calibration for Sitting Posture Analysis, IEEE Sens. J., 13, 3926, 10.1109/JSEN.2013.2259589 · doi:10.1109/jsen.2013.2259589
  16. Suprapto, S.S., Setiawan, A.W., Zakaria, H., Adiprawita, W., and Supartono, B. (2017, January 6–7). Low-Cost Pressure Sensor Matrix Using Velostat. Proceedings of the 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. · doi:10.1109/icici-bme.2017.8537720
  17. van Donselaar, R., and Chen, W. (2011, January 26–29). Design of a Smart Textile Mat to Study Pressure Distribution on Multiple Foam Material Configurations. Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies, Barcelona, Spain. ISABEL’11. · DOI
  18. Li, E., Lin, X., Seet, B., Joseph, F., and Neville, J. (2019, January 20–23). Low Profile and Low Cost Textile Smart Mat for Step Pressure Sensing and Position Mapping. Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Auckland, New Zealand. · doi:10.1109/i2mtc.2019.8826892
  19. Kumar, 2018, Development of Electronic Floor Mat for Fall Detection and Elderly Care, Asian J. Sci. Res., 11, 344, 10.3923/ajsr.2018.344.356 · doi:10.3923/ajsr.2018.344.356
  20. Kalantari, 2012, A New Approach for Modeling Piezoresistive Force Sensors Based on Semiconductive Polymer Composites, IEEE/ASME Trans. Mechatron., 17, 572, 10.1109/TMECH.2011.2108664 · doi:10.1109/tmech.2011.2108664
  21. 2017, Test and fabrication of piezoresistive sensors for contact pressure measurement, Rev. Fac. Ing. Univ. Antioq., 82, 47
  22. 2019, Circuit Analysis of Matrix-Like Resistor Networks for Eliminating Crosstalk in Pressure Sensitive Mats, IEEE Sens. J., 19, 8027, 10.1109/JSEN.2019.2918592 · DOI
  23. Shu, 2010, In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array, Bioinform. Bioeng., 14, 767
  24. Chen, B., Liu, P., Xiao, F., Liu, Z., and Wang, Y. (2021). Review of the Upright Balance Assessment Based on the Force Plate. Int. J. Environ. Res. Public Health, 18. · DOI
  25. Wojciechowska-Maszkowska, B., Marcinów, R., Iskra, J., and Tataruch, R. (2021). Postural Stability in Athletes during Special Hurdle Tests without a Definite Dominant Leg. Int. J. Environ. Res. Public Health, 18. · DOI
  26. Wu, 2017, Scanning Approaches of 2-D Resistive Sensor Arrays: A Review, IEEE Sens. J., 17, 914, 10.1109/JSEN.2016.2641001 · DOI
  27. Virtanen, 2020, SciPy 1.0: Fundamental Algorithms for Scientific Computing in Python, Nat. Methods, 17, 261, 10.1038/s41592-019-0686-2 · DOI · Paper page
  28. Rocha, Á., Adeli, H., Reis, L.P., and Costanzo, S. (2019). The Use of Virtual Cues in Acquired Brain Injury Rehabilitation. Meaningful Evidence. New Knowledge in Information Systems and Technologies, Springer International Publishing.

Metadata

Authors
Martinez-Cesteros, J., Medrano-Sanchez, C., Plaza-Garcia, I., Igual-Catalan, R., & Albiol-Pérez, S.
Venue
International Journal of Environmental Research and Public Health
Publisher
MDPI AG
Published
2021-06-02
Volume
18
Issue
11
Pages
5958
ISSN
1660-4601
Cited by
20
References
1
Language
en
Funders
  • Ministerio de Ciencia, Innovación y Universidades (FPU-18/04282)
  • Instituto de Salud Carlos III, Spanish Government / European Regional Development Fund, A way to build Europe (FIS PI17/00465)
  • "Fondo Social Europeo (Programa Operativo FEDER 2014-2020 Construyendo Europa desde Aragón)” / “Diputación General de Aragón” (T49_20R)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study. https://app.cochat.ai/papers/10.3390/ijerph18115958
The paper
Martinez-Cesteros, J., Medrano-Sanchez, C., Plaza-Garcia, I., Igual-Catalan, R., & Albiol-Pérez, S. (2021). A Velostat-Based Pressure-Sensitive Mat for Center-of-Pressure Measurements: A Preliminary Study. International Journal of Environmental Research and Public Health. https://doi.org/10.3390/ijerph18115958

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.