CoChat

Impact of Wearing on Filtration Performance of Electrostatic Filter Face Masks

Open access
Pierlot, Anthony P., Alexander, David L. J., Schütz, Jürg A. · 2022 · International Journal of Environmental Research and Public Health

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Certified disposable respirators afford important protection from hazardous aerosols but lose performance as they are worn. This study examines the effect of wear time on filtration efficiency. Disposable respirators were worn by CSIRO staff over a period of 4 weeks in early 2020. Participants wore the respirator masks for given times up to eight hours whilst working in laboratory/office environments. At that time COVID-19 precautions required staff to wear surgical (or other) masks and increase use of hand sanitizer from dispenser stations. Results obtained from a test group of ten individuals without health preconditions show an increasing number of masks failing with wear time, while the remainder continue to perform nearly unaffected for up to 8 h. Some masks were found to retain filtration performance better than others, possibly due to the type of challenge they were subjected to by the wearer. However, the rate and extent of decay are expected to differ between environments since there are many contributing factors and properties of the aerosol challenge cannot be controlled in a live trial. Penetration and variability increased during wear; the longer the wear time, the more deleterious to particle removal, particularly after approximately 2 h of wear. This behavior is captured in a descriptive statistical model based on results from a trial with this test group. The effectiveness of the masks in preventing the penetration of KCl particles was determined before and after wearing, with the analysis focusing on the most penetrating particles in a size range of 0.3–0.5 µm diameter where respirator masks are most vulnerable. The basic elements of the study, including the approach to filter testing and sample sanitization, are broadly applicable. Conclusions also have applicability to typical commercially available single-use respirator masks manufactured from melt blown polypropylene as they are reliant on the same physical principles for particle capture and electrostatic enhancement was comparable for the particle size range used for detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijerph19095032

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) An example of the particle-size dependence of penetration for charged and discharged wool/polypropylene (Wool–PP, WP) and melt blown polypropylene (Meltblown PP, MBP; Shanghai Da Sheng [5]) mask media when tested at a face velocity of 0.15 m/s. Pressure drop, thickness, fabric areal density, maximum penetration, and most penetrable particle size (MPPS) of MBP: 200 Pa, 3.0 mm, 280 g/m2, 0.5%, 48 nm; WP: 50 Pa, 8.8 mm, 600 g/m2, 2.2%, and 46 nm, respectively. The particle diameter size range used for measuring penetration P0.3 has been highlighted in green. Trendlines (B-Spline) have been added for illustration purposes to measurements represented by dots. (b) Fiber-polymer specific charge distribution in electrostatically enhanced media of the tribo-electric type. (c) Charge distribution resulting from DC corona charging using a unipolar electrode configuration (example for unipolar, positive electrode configuration [8]).
Figure 1 (a) An example of the particle-size dependence of penetration for charged and discharged wool/polypropylene (Wool–PP, WP) and melt blown polypropylene (Meltblown PP, MBP; Shanghai Da Sheng [5]) mask media when tested at a face velocity of 0.15 m/s. Pressure drop, thickness, fabric areal density, maximum penetration, and most penetrable particle size (MPPS) of MBP: 200 Pa, 3.0 mm, 280 g/m2, 0.5%, 48 nm; WP: 50 Pa, 8.8 mm, 600 g/m2, 2.2%, and 46 nm, respectively. The particle diameter size range used for measuring penetration P0.3 has been highlighted in green. Trendlines (B-Spline) have been added for illustration purposes to measurements represented by dots. (b) Fiber-polymer specific charge distribution in electrostatically enhanced media of the tribo-electric type. (c) Charge distribution resulting from DC corona charging using a unipolar electrode configuration (example for unipolar, positive electrode configuration [8]).CC BY · PubMed Central
Figure 2 Wool–polypropylene fabric filter disc mounted with air permeable wrap to wearer’s face.
Figure 2 Wool–polypropylene fabric filter disc mounted with air permeable wrap to wearer’s face.CC BY · PubMed Central
Figure 3 Modelled respirator leakage rates (hole penetration) as a function of face velocity for wool/polypropylene and melt blown polypropylene filter media with pressure drops of 30 Pa and 200 Pa at a face velocity of 0.15 m/s. Trendlines (modified Bézier) have been added for illustration purposes to calculated data represented by dots.
Figure 3 Modelled respirator leakage rates (hole penetration) as a function of face velocity for wool/polypropylene and melt blown polypropylene filter media with pressure drops of 30 Pa and 200 Pa at a face velocity of 0.15 m/s. Trendlines (modified Bézier) have been added for illustration purposes to calculated data represented by dots.CC BY · PubMed Central
Figure 4 Penetration (P0.3) of mask samples before (circle) and after (triangle) wearing for specified times (1, 2, 4, and 8 h) and control samples that were not worn.
Figure 4 Penetration (P0.3) of mask samples before (circle) and after (triangle) wearing for specified times (1, 2, 4, and 8 h) and control samples that were not worn.CC BY · PubMed Central
Figure 5 Penetration (P0.3) of samples before and after wearing for 0–8 h as a function of areal density (basis weight). Filter tests were conducted after the first (San = 1) and second (San = 2) heat sanitization treatments. A linear fit of the logarithm of the average particle penetration Log(P) over areal density for unworn media (San = 1) is shown to illustrate the expected trend.
Figure 5 Penetration (P0.3) of samples before and after wearing for 0–8 h as a function of areal density (basis weight). Filter tests were conducted after the first (San = 1) and second (San = 2) heat sanitization treatments. A linear fit of the logarithm of the average particle penetration Log(P) over areal density for unworn media (San = 1) is shown to illustrate the expected trend.CC BY · PubMed Central
Figure 6 Dry weight ratio, worn/unworn of trial samples with wear times of 0, 1, 2, 4, or 8 h.
Figure 6 Dry weight ratio, worn/unworn of trial samples with wear times of 0, 1, 2, 4, or 8 h.CC BY · PubMed Central
Figure 7 Pressure drop of samples before and after wearing by participants.
Figure 7 Pressure drop of samples before and after wearing by participants.CC BY · PubMed Central
Figure 8 Dust loading performances of sanitized mask media in unworn and worn state. Low and high loss refer to the observed level of deterioration that the mask media incurred during wear. Mathematical fit functions used to illustrate dust loading dependencies were described in [25].
Figure 8 Dust loading performances of sanitized mask media in unworn and worn state. Low and high loss refer to the observed level of deterioration that the mask media incurred during wear. Mathematical fit functions used to illustrate dust loading dependencies were described in [25].CC BY · PubMed Central
Figure 9 Penetration (P0.3) of samples after wearing for 0–8 h. Experimental results are shown by triangles; the red curve shows modelled mean penetration. Light shading gives 95% confidence intervals for mean penetration, and dark shading for observations on individual masks.
Figure 9 Penetration (P0.3) of samples after wearing for 0–8 h. Experimental results are shown by triangles; the red curve shows modelled mean penetration. Light shading gives 95% confidence intervals for mean penetration, and dark shading for observations on individual masks.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 2

  1. Schütz J.A. Maxwell J.M. Huson M.G. 3.7 Hunt for Charges in Electret Filters with a Scanning Probe Microscope. In Proceedings of the TANDEC 11th Annual International Nonwovens Conference, The University of Tennessee Knoxville, TN, USA 6–8 November 2001
  2. Schütz J.A. Interdependence of Fine Particle Filtration Performance and Dust Load for Electrostatic Media Filtration 2008 8 252 258

Cited by

See all 7

Metadata

Authors
Pierlot, A. P., Alexander, D. L. J., & Schütz, J. A.
Affiliations
Commonwealth Scientific and Industrial Research Organisation (AU)
Corresponding author
Alexander, David L. J.
Venue
International Journal of Environmental Research and Public Health
Publisher
MDPI AG
Published
2022-04-21
Volume
19
Issue
9
Pages
5032
ISSN
1660-4601 (ISSN-L)
OpenAlex
W4224301378
Cited by
7
References
21
Citations by year
2026: 2 · 2024: 1 · 2023: 2 · 2022: 2
FWCI
0.34
Type
journal article
Language
en
Open access
Locations
  • International Journal of Environmental Research and Public Health (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
  • Australian Government
  • Commonwealth Scientific and Industrial Research Organisation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
Keywords
filtration efficiency, electrostatic filtration, particle penetration, aerosol challenge, COVID-19 pandemic, hand sanitizer, particle size distribution
MeSH terms
COVID-19, Aerosols, Filtration, Humans, Masks, Particle Size, Respiratory Protective Devices, Static Electricity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.