Advancements in Monitoring Water Quality Based on Various Sensing Methods: A Systematic Review
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Nowadays, water pollution has become a global issue affecting most countries in the world. Water quality should be monitored to alert authorities on water pollution, so that action can be taken quickly. The objective of the review is to study various conventional and modern methods of monitoring water quality to identify the strengths and weaknesses of the methods. The methods include the Internet of Things (IoT), virtual sensing, cyber-physical system (CPS), and optical techniques. In this review, water quality monitoring systems and process control in several countries, such as New Zealand, China, Serbia, Bangladesh, Malaysia, and India, are discussed. Conventional and modern methods are compared in terms of parameters, complexity, and reliability. Recent methods of water quality monitoring techniques are also reviewed to study any loopholes in modern methods. We found that CPS is suitable for monitoring water quality due to a good combination of physical and computational algorithms. Its embedded sensors, processors, and actuators can be designed to detect and interact with environments. We believe that conventional methods are costly and complex, whereas modern methods are also expensive but simpler with real-time detection. Traditional approaches are more time-consuming and expensive due to the high maintenance of laboratory facilities, involve chemical materials, and are inefficient for on-site monitoring applications. Apart from that, previous monitoring methods have issues in achieving a reliable measurement of water quality parameters in real time. There are still limitations in instruments for detecting pollutants and producing valuable information on water quality. Thus, the review is important in order to compare previous methods and to improve current water quality assessments in terms of reliability and cost-effectiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infrared Spectroscopy: Fundamentals and Applications
Stuart, B. H. (2004) · Analytical Techniques in the Sciences · doi:10.1002/0470011149 · Cited by 4,427 · cited 1×
“Spectroscopy normally uses a light source or a laser as an emitter and a detector or spectrometer for spectral analysis [81].”
BackgroundThe Past, Present and Future of Cyber-Physical Systems: A Focus on Models
Lee, E. (2015) · Sensors · doi:10.3390/s150304837 · Cited by 682
Hrudey, S. E., Payment, P., Huck, P. M., Gillham, R. W., & Hrudey, E. J. (2003) · Water Science & Technology · doi:10.2166/wst.2003.0146 · Cited by 477 · cited 1×
“For instance, 2300 people were affected by drinking contaminated water, and as a result, an outbreak of a waterborne disease epidemic happened in Walkerton, Ontario, Canada, in 2000, which was sourced from cattle manure from a nearby farm [4,5].”
BackgroundCarrard, N., Foster, T., & Willetts, J. (2019) · Water · doi:10.3390/w11081605 · Cited by 353 · cited 1×
“Groundwater is one of the critical sources of drinking water for households because 79% of the total population across 10 southeast Asia and pacific countries use groundwater which has common concerns related to pollution from unsafe sanitation, leading to dry season shortages and others [11].”
BackgroundZulkifli, S. N., Rahim, H. A., & Lau, W.-J. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.09.078 · Cited by 335 · cited 2×
“The instruments used for vibrational spectroscopy are Infrared (IR) and Raman spectrometer [22].”
BackgroundMethodReal-time water quality monitoring using Internet of Things in SCADA
Saravanan, K., Anusuya, E., Kumar, R., & Son, L. H. (2018) · Environmental Monitoring and Assessment · doi:10.1007/s10661-018-6914-x · Cited by 203
A global dataset of surface water and groundwater salinity measurements from 1980–2019
Thorslund, J., & van Vliet, M. T. H. (2020) · Scientific Data · doi:10.1038/s41597-020-0562-z · Cited by 143
Cyber-physical systems for water sustainability: challenges and opportunities
Wang, Z., Song, H., Watkins, D. W., Ong, K. G., Xue, P., Yang, Q., & Shi, X. (2015) · IEEE Communications Magazine · doi:10.1109/mcom.2015.7105668 · Cited by 141 · cited 3×
“Wang [16] has discussed the opportunities and challenges of CPS for water sustainability which include four factors; sensing and instrumentation; communications and networking; computing; and control.”
BackgroundInfluentialAutonomous Water Quality Monitoring and Water Surface Cleaning for Unmanned Surface Vehicle
Chang, H.-C., Hsu, Y., Hung, S.-S., Ou, G.-R., Wu, J.-R., & Hsu, C. (2021) · Sensors · doi:10.3390/s21041102 · Cited by 125 · cited 2×
“[61] developed a system that used sensors to develop an unmanned surface vehicle (MF-USV) to avoid any obstacles and monitor the water quality system and water surface cleaning system.”
BackgroundWater Quality Monitoring with Arduino Based Sensors
Hong, W., Shamsuddin, N., Abas, P. E., Apong, R. A. A. H. M., Masri, Z., Suhaimi, H., Gödeke, S. H., & Noh, M. (2021) · Environments · doi:10.3390/environments8010006 · Cited by 123 · cited 2×
“Hong [59] demonstrated water quality monitoring based on Arduinobased sensor systems.”
Background
Cited by
Mafe, A. N., Edo, G. I., Makia, R. S., Joshua, O. A., Akpoghelie, P. O., Gaaz, T. S., Jikah, A. N., Yousif, E., Isoje, E. F., Igbuku, U. A., et al. (2024) · Food Chemistry Advances · doi:10.1016/j.focha.2024.100852 · Cited by 235
Miller, T., Durlik, I., Kostecka, E., Kozlovska, P., Łobodzińska, A., Sokołowska, S., & Nowy, A. (2025) · Electronics · doi:10.3390/electronics14040696 · Cited by 199
Metadata
- Authors
- Zainurin, S. N., Wan Ismail, W. Z., Mahamud, S. N. I., Ismail, I., Jamaludin, J., Ariffin, K. N. Z., & Wan Ahmad Kamil, W. M.
- Venue
- International Journal of Environmental Research and Public Health
- Publisher
- MDPI AG
- Published
- 2022-10-28
- Volume
- 19
- Issue
- 21
- Pages
- 14080
- ISSN
- 1660-4601 (ISSN-L)
- OpenAlex
- W4307942328
- Cited by
- 158
- References
- 37
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.